ATLAS Systém koronárních stentů uvolňujících léky kobalt-chrom
A kobalt-chrom koronární stent trvanlivá radiální pevnost a vynikající sledovatelnost, vhodné pro komplexní nebo kalcifikované koronárních lézí při zajištění minimálního zpětného rázu.
Na stránkách ATLAS Drug Eluting Coronary Stent System is a next-generation cobalt-chromium (CoCr) stent platform coated with a sirolimus formulation (1 µg/mm²) designed to reduce restenosis in patients with coronary artery disease. By combining advanced laser-cutting technology and a clinically proven antiproliferative drug, the ATLAS system delivers durable vessel patency and a high safety profile in both de novo lesions and in-stent restenosis scenarios.
Cobalt-Chromium Alloy (L605) Construction
- Ensures exceptional strength-to-thickness ratio, enabling thinner struts without compromising radial force.
- Exhibits excellent corrosion resistance and biocompatibility for a stable healing environment.
Laser-Cut Stent Design
- Precision machining yields consistent strut geometry, promoting uniform drug distribution and an even healing surface along the vessel wall.
- Enhances stent deliverability, allowing smooth passage through calcified or tortuous coronary segments.
Sirolimus Elution Profile
- 1 µg/mm² of sirolimus is coated onto the stent’s surface, ensuring a sustained, controlled release that minimizes in-stent neointimal growth.
- Controlled drug release aids in rapid endothelialization, lowering the risk of late stent thrombosis.
Radiopaque Pt-Ir Markers
- Platinum-iridium markers at stent edges enable precise visibility under fluoroscopy.
- Facilitates accurate positioning during percutaneous coronary intervention (PCI) procedures.
High-Pressure Capability
interventional cardiologists flexibility to optimize stent expansion based on lesion complexity.
| Specifikace | Detail / Hodnota |
| Název produktu | Atlas Coronary Stent (Cobalt Chromium) |
| Stent Type | Balloon-Expandable Coronary Stent |
| Materiál | Cobalt-Chromium Alloy |
| Strut Thickness | ~80 µm (typical) |
| Design | Open-cell or hybrid-cell architecture (depending on exact model) |
| Nominal Pressure (NP) | 9–10 atm |
| Rated Burst Pressure (RBP) | ~14–16 atm |
| Stent Delivery System | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
| Kompatibilita vodicích drátů | 0.014” |
| Stent Surface | Bare-metal or optional drug-eluting polymer (if applicable) |
| Indikace | Coronary artery lesion scaffolding, single or multivessel disease, potential usage in small/medium/large vessels |
| Kontraindikace | Lesions unsuited for balloon-expandable stent therapy (e.g., severely calcified, left main trunk, etc.), or as per physician discretion |
| Sterilita | Sterilní (ethylenoxid) |
| Jednorázové použití | Ano |
| Doba použitelnosti | 2–3 years (depending on final packaging and polymer, if any) |
| Provozní teplota | Recommended 15–25 °C for storage |
Podrobné objednávání podle velikosti a kódy výrobků
| Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Kód produktu |
| 2.00 | 8 | 9 | 14 | ATLS-CC-2.00x08 |
| 2.00 | 12 | 9 | 14 | ATLS-CC-2.00x12 |
| 2.00 | 15 | 9 | 14 | ATLS-CC-2.00x15 |
| 2.00 | 18 | 10 | 16 | ATLS-CC-2.00x18 |
| 2.00 | 24 | 10 | 16 | ATLS-CC-2.00x24 |
| 2.00 | 28 | 10 | 16 | ATLS-CC-2.00x28 |
| 2.00 | 32 | 10 | 16 | ATLS-CC-2.00x32 |
| 2.00 | 38 | 10 | 16 | ATLS-CC-2.00x38 |
| 2.25 | 8 | 9 | 14 | ATLS-CC-2.25x08 |
| 2.25 | 12 | 9 | 14 | ATLS-CC-2.25x12 |
| 2.25 | 15 | 9 | 14 | ATLS-CC-2.25x15 |
| 2.25 | 18 | 10 | 16 | ATLS-CC-2.25x18 |
| 2.25 | 24 | 10 | 16 | ATLS-CC-2.25x24 |
| 2.25 | 28 | 10 | 16 | ATLS-CC-2.25x28 |
| 2.25 | 32 | 10 | 16 | ATLS-CC-2.25x32 |
| 2.25 | 38 | 10 | 16 | ATLS-CC-2.25x38 |
| 2.50 | 8 | 9 | 14 | ATLS-CC-2.50x08 |
| 2.50 | 12 | 9 | 14 | ATLS-CC-2.50x12 |
| 2.50 | 15 | 9 | 14 | ATLS-CC-2.50x15 |
| 2.50 | 18 | 10 | 16 | ATLS-CC-2.50x18 |
| 2.50 | 24 | 10 | 16 | ATLS-CC-2.50x24 |
| 2.50 | 28 | 10 | 16 | ATLS-CC-2.50x28 |
| 2.50 | 32 | 10 | 16 | ATLS-CC-2.50x32 |
| 2.50 | 38 | 10 | 16 | ATLS-CC-2.50x38 |
| 2.75 | 8 | 9 | 14 | ATLS-CC-2.75x08 |
| 2.75 | 12 | 9 | 14 | ATLS-CC-2.75x12 |
| 2.75 | 15 | 9 | 14 | ATLS-CC-2.75x15 |
| 2.75 | 18 | 10 | 16 | ATLS-CC-2.75x18 |
| 2.75 | 24 | 10 | 16 | ATLS-CC-2.75x24 |
| 2.75 | 28 | 10 | 16 | ATLS-CC-2.75x28 |
| 2.75 | 32 | 10 | 16 | ATLS-CC-2.75x32 |
| 2.75 | 38 | 10 | 16 | ATLS-CC-2.75x38 |
| 3.00 | 8 | 9 | 14 | ATLS-CC-3.00x08 |
| 3.00 | 12 | 9 | 14 | ATLS-CC-3.00x12 |
| 3.00 | 15 | 9 | 14 | ATLS-CC-3.00x15 |
| 3.00 | 18 | 10 | 16 | ATLS-CC-3.00x18 |
| 3.00 | 24 | 10 | 16 | ATLS-CC-3.00x24 |
| 3.00 | 28 | 10 | 16 | ATLS-CC-3.00x28 |
| 3.00 | 32 | 10 | 16 | ATLS-CC-3.00x32 |
| 3.00 | 38 | 10 | 16 | ATLS-CC-3.00x38 |
| 3.25 | 12 | 9 | 14 | ATLS-CC-3.25x12 |
| 3.25 | 15 | 9 | 14 | ATLS-CC-3.25x15 |
| 3.25 | 18 | 10 | 16 | ATLS-CC-3.25x18 |
| 3.25 | 24 | 10 | 16 | ATLS-CC-3.25x24 |
| 3.25 | 28 | 10 | 16 | ATLS-CC-3.25x28 |
| 3.25 | 32 | 10 | 16 | ATLS-CC-3.25x32 |
| 3.25 | 38 | 10 | 16 | ATLS-CC-3.25x38 |
| 3.50 | 8 | 9 | 14 | ATLS-CC-3.50x08 |
| 3.50 | 12 | 9 | 14 | ATLS-CC-3.50x12 |
| 3.50 | 15 | 9 | 14 | ATLS-CC-3.50x15 |
| 3.50 | 18 | 10 | 16 | ATLS-CC-3.50x18 |
| 3.50 | 24 | 10 | 16 | ATLS-CC-3.50x24 |
| 3.50 | 28 | 10 | 16 | ATLS-CC-3.50x28 |
| 3.50 | 32 | 10 | 16 | ATLS-CC-3.50x32 |
| 3.50 | 38 | 10 | 16 | ATLS-CC-3.50x38 |
| 4.00 | 8 | 9 | 14 | ATLS-CC-4.00x08 |
| 4.00 | 12 | 9 | 14 | ATLS-CC-4.00x12 |
| 4.00 | 15 | 9 | 14 | ATLS-CC-4.00x15 |
| 4.00 | 18 | 10 | 16 | ATLS-CC-4.00x18 |
| 4.00 | 24 | 10 | 16 | ATLS-CC-4.00x24 |
| 4.00 | 28 | 10 | 16 | ATLS-CC-4.00x28 |
| 4.00 | 32 | 10 | 16 | ATLS-CC-4.00x32 |
| 4.00 | 38 | 10 | 16 | ATLS-CC-4.00x38 |
Související produkty
-

InWIRE 0,014" a 0,018" CTO vodicí drát
Čtěte víceŘada vysoce výkonné nabídka vodicích drátů trvanlivé nitinol nebo nerezová jádra, hydrofilní povlaky a různé tvary hrotů pro křížení. kalcifikované nebo komplexní koronární a periferní léze.
-

Atlas Koronární stentový systém z nerezové oceli
Čtěte víceA nerezová ocel nabídka koronárních stentů robustní strukturální integritu a snadno pro rutinní perkutánní koronární intervence (PCI), které vyvažují nákladovou efektivitu a spolehlivý výkon.
-

Peta Sternální uzavírací deska
Čtěte víceA titan nebo slitina systém sternální desky poskytující pevný fixace po střední sternotomii, která zvyšuje sternální stabilita a snížení rizika infekce nebo dehiscence po kardiochirurgické operaci.
-

Hero Mechanický systém odstraňování olova
Čtěte víceA mechanické alternativa pro extrakce olova, které používají specializované uzamykací styly nebo pouzdra, aby se vytlačit fibrotické nástavce, které zajišťují stabilní trakce pro bezpečné odstranění.