Spider™ Peripheral Detachable Coil System (Detachable Pushable)
A detachable coil kit for 栓塞 of peripheral aneurysms, AV fistulas, or abnormal vessels, providing stable coil packing with 受控 mechanical detachment.
The Spider™ Peripheral Detachable Coil System in its detachable pushable configuration is engineered by Invamed—a global medical device manufacturer—to address peripheral aneurysm occlusion, vascular malformations, or fistulae requiring controlled coil placement. By offering a pushable yet detachable delivery mechanism, Spider™ affords the precision of in-place detachment without the complexity of electrolytic release, optimizing procedural control and reducing risk of coil migration.
Detachable Pushable Delivery
Combines the ease of a pushable coil insertion with the detachment control typically associated with mechanical or electrolytic systems, enabling safe retrieval or repositioning before final deployment.
Platinum Coil
High radiopacity ensures real-time fluoroscopic monitoring, helping interventionalists confirm accurate coil positioning and packing density.
Soft & Conformable
The flexible coil design adapts to complex vessel anatomies or aneurysmal sacs, minimizing stress on fragile vessel walls.
Versatile Embolization
Ideal for small-to-moderate peripheral aneurysms, arteriovenous malformations (AVMs), or abnormal vascular communications, delivering precise occlusion.
適應症
Aneurysm repair (e.g., peripheral, visceral), AVM or fistula occlusion in peripheral territories, or general endovascular procedures requiring dense coil packing.
禁忌症
Vessels too small or tortuous to pass the delivery catheter, active infection at the access site, or scenarios where coil retrieval is not feasible.
產品規格
規格 | 細節 / 價值 |
產品名稱 | Spider Peripheral Detachable Coil System |
預期用途 | Endovascular embolization of peripheral aneurysms, AV fistulas, or abnormal vessels |
Coil Material | Platinum or platinum-tungsten alloy with detachable mechanism |
Detachment Method | Mechanical or electrolytic (verify final model) |
Coil Diameter Range | ~1.5–20 mm (varies by catalog code) |
Coil Length Range | ~1–40 cm (depending on coil diameter and framing vs. filling type) |
Delivery Microcatheter | Typically 2.3–2.7F inner diameter, 0.016–0.021” ID |
放射能力 | Platinum coil for fluoroscopic visualization |
無菌 | 無菌,單次使用 |
保質期 | ~3–5 years at 15–25 °C |
臨床適應症 | Peripheral aneurysm occlusion, AVF closure, selective vessel sacrifice |
禁忌症 | Vessels too small or tortuous to accommodate microcatheter, known device material allergies |
訂購與尺寸表
Coil Diameter (mm) | Coil Length (cm) | Detachment Type | 產品編號 | 注意事項 |
1.5 | 2 | Mechanical | SPD-P-1.5x2-M | Very small coil for micro-aneurysms |
1.5 | 4 | Electrolytic | SPD-P-1.5x4-E | Extended length, small diameter |
3.0 | 10 | Mechanical | SPD-P-3.0x10-M | Mid-range coil diameter, framing type |
3.0 | 15 | Electrolytic | SPD-P-3.0x15-E | Longer filling coil for larger sac |
5.0 | 15 | Mechanical | SPD-P-5.0x15-M | Medium coil for moderate aneurysms |
5.0 | 20 | Electrolytic | SPD-P-5.0x20-E | Extended coil length, filling type |
10.0 | 20 | Mechanical | SPD-P-10.0x20-M | Larger diameter coil for bigger aneurysms |
10.0 | 40 | Electrolytic | SPD-P-10.0x40-E | Maximum length coil for large-volume occlusion |
相關商品
-
AngioCATH 導引導管
查看內容高性能導引導管,具有 最佳扭力 回應和 精確提示 形狀 冠脉 或 外周 介入,確保穩定的裝置傳輸和成像清晰度。
-
MicroDELIVERY 栓塞導管
查看內容優化的微導管 精密 可將栓塞劑輸送至小血管區域或遠端血管區域,確保均勻分佈和最小回流。
-
Atlas 不銹鋼冠狀動脈支架系統
查看內容A 不銹鋼 冠狀動脈支架產品 穩健 結構完整性和 輕鬆 適用於常規經皮冠狀動脈介入術 (PCI),兼顧成本效益與可靠效能。
-
Extender 紫杉醇藥物洗淨 PTCA 球囊導管
查看內容A 紫杉醇塗層 冠狀動脈球囊導管,旨在 減少再狭窄 在經皮冠狀血管成形術 (PTCA) 期間,可確保有效地將藥物輸送到血管壁。