Aspiration Thrombectomy Techniques: Comparative Analysis of Direct vs. Intermediate Catheter Approaches
簡介
Acute ischemic stroke remains one of the most devastating neurological emergencies, with approximately 800,000 cases annually in the United States alone and millions more worldwide. The evolution of mechanical thrombectomy has revolutionized the management of large vessel occlusion strokes, dramatically improving functional outcomes when performed in appropriate patients within the therapeutic time window. As thrombectomy techniques have matured, aspiration thrombectomy has emerged as a fundamental approach, either as a standalone technique or in combination with stent retrievers. Within the aspiration paradigm, significant debate exists regarding the optimal catheter configuration and technical approach, particularly concerning the use of direct aspiration versus intermediate catheter techniques. As we navigate through 2025, the landscape of aspiration thrombectomy has evolved significantly, guided by technological advances, refined protocols, and emerging evidence that collectively enhance procedural success and clinical outcomes.
The journey of aspiration thrombectomy began with rudimentary aspiration catheters, progressed through increasingly sophisticated large-bore designs, and has now reached an era of advanced aspiration systems like the ThrombX Aspiration System that integrate optimized catheter geometries, specialized tip designs, and powerful aspiration sources. These developments have dramatically improved first-pass recanalization rates, reduced procedural times, and potentially enhanced clinical outcomes while minimizing complications.
This comprehensive analysis explores the current state of aspiration thrombectomy techniques in 2025, with particular focus on the comparative effectiveness of direct aspiration versus intermediate catheter approaches across different anatomical and clot scenarios. From technical considerations to next-generation systems, we delve into the evidence-based approaches that are reshaping the landscape of mechanical thrombectomy for acute ischemic stroke.
Understanding Aspiration Thrombectomy Fundamentals
Core Principles and Terminology
Before exploring comparative techniques, it is essential to understand the fundamental principles underlying aspiration thrombectomy:
-
Direct aspiration (ADAPT – A Direct Aspiration first Pass Technique): The approach of advancing a large-bore aspiration catheter directly to the face of the thrombus, applying vacuum suction, and removing the clot either through ingestion into the catheter or by withdrawing the catheter while maintaining aspiration.
-
Intermediate catheter aspiration: The use of a moderately sized catheter positioned in the proximal vessel (e.g., distal internal carotid artery or proximal M1) through which a smaller microcatheter and/or stent retriever is navigated to the occlusion site, providing both access support and supplemental aspiration during thrombectomy.
-
Balloon guide catheter (BGC): A specialized guide catheter with an inflatable balloon that allows for flow arrest in the proximal vessel during thrombectomy, reducing distal embolization and enhancing aspiration efficiency.
-
First-pass effect (FPE): Complete or near-complete reperfusion (mTICI 2c/3) achieved with a single thrombectomy attempt, associated with superior clinical outcomes.
Evolution of Aspiration Technology
The technological journey of aspiration thrombectomy has been marked by several distinct generations:
- First-generation aspiration catheters (2010-2015):
- Exemplified by the Penumbra Separator system
- Relatively small inner diameters (0.032″-0.041″)
- Required separator device for clot disruption
- Limited trackability and aspiration force
-
Primarily used as adjunct to stent retrievers
-
Second-generation aspiration catheters (2016-2020):
- Represented by devices like Penumbra ACE, Sofia, and React
- Larger inner diameters (0.060″-0.068″)
- Improved trackability and distal access
- Eliminated need for separator device
-
Enabled direct aspiration as primary approach
-
Current-generation aspiration systems (2021-2025):
- Exemplified by the ThrombX Aspiration System
- Ultra-large bore designs (0.070″-0.088″)
- Optimized distal tip configurations
- Enhanced trackability through varied stiffness profiles
- Advanced coating technologies reducing friction
- Integrated with high-power aspiration pumps
Key Technical Components
Modern aspiration thrombectomy incorporates several critical technical elements:
- Catheter design features:
- Inner diameter: Critical determinant of aspiration force
- Distal tip design: Affects trackability and clot engagement
- Shaft construction: Influences pushability and navigation
- Coating technologies: Reduces friction during navigation
-
Marker bands: Enables precise positioning at occlusion site
-
Aspiration sources:
- Vacuum pumps: Provide continuous high-power aspiration
- Aspiration syringes: Manual aspiration with tactile feedback
- Hybrid systems: Combining pump and syringe advantages
- Pressure monitoring: Real-time feedback on aspiration effectiveness
-
Flow restoration indicators: Signals successful clot removal
-
Accessory devices:
- Microcatheters: Navigation through tortuous anatomy
- Microwires: Vessel selection and catheter support
- Support catheters: Provides stability during device delivery
- Balloon guide catheters: Proximal flow control
-
Stent retrievers: Complementary approach for combined techniques
-
Procedural adjuncts:
- Imaging guidance: Angiography, cone-beam CT
- Contrast injection protocols: Visualization of occlusion and collaterals
- Antiplatelet/anticoagulant management: Periprocedural medication protocols
- Anesthetic approaches: Conscious sedation vs. general anesthesia
- Neuroprotection strategies: Blood pressure management, oxygenation
Direct Aspiration Technique: Current State of the Art
Technical Approach
The refined direct aspiration technique involves several key steps:
- Access and navigation:
- Femoral or radial arterial access
- Placement of appropriate guide catheter (conventional or balloon guide)
- Navigation to proximal vessel (internal carotid or vertebral artery)
- Microcatheter and microwire navigation past occlusion site
-
Exchange for aspiration catheter over microwire or through microcatheter
-
Clot engagement:
- Positioning aspiration catheter directly at proximal face of thrombus
- Confirmation of position with gentle contrast injection
- Initiation of aspiration before final advancement
- Gentle forward pressure to embed catheter tip into thrombus
-
Tactile feedback of catheter “wedging” into clot
-
Aspiration and retrieval:
- Continuous aspiration for 1-3 minutes if no immediate ingestion
- Assessment for flow restoration through catheter
- If successful ingestion, withdrawal of catheter while maintaining aspiration
- If unsuccessful, gentle retraction of catheter while maintaining aspiration
-
Simultaneous proximal aspiration through guide catheter
-
Procedural completion:
- Angiographic assessment of reperfusion
- Repeat attempts if necessary with same or different approach
- Evaluation of distal emboli in new territories
- Assessment for underlying stenosis or dissection
- Consideration of adjunctive treatments if needed
Technical Refinements in Direct Aspiration
Several important refinements have enhanced direct aspiration success:
- “CAPTIVE” technique (Continuous Aspiration Prior To Intracranial Vascular Embolectomy):
- Continuous aspiration during catheter advancement
- Reduces risk of clot fragmentation and distal embolization
- Provides immediate aspiration upon clot contact
- Particularly valuable in tortuous anatomy
-
Demonstrated 5-10% improvement in first-pass success
-
“Push and fluff” technique:
- Gentle forward pressure after initial clot contact
- Allows catheter to deform and better engage thrombus
- Maximizes surface area contact with clot
- Reduces likelihood of catheter deflection
-
Particularly valuable for firm, fibrin-rich thrombi
-
Dual aspiration systems:
- Simultaneous aspiration through both aspiration and guide catheters
- Maximizes negative pressure gradient
- Reduces risk of distal embolization during withdrawal
- Particularly valuable for large clot burden
-
Requires coordinated team approach
-
Balloon guide catheter integration:
- Proximal flow arrest during aspiration and withdrawal
- Reduces antegrade flow that may dislodge thrombus fragments
- Enhances aspiration force at catheter tip
- Demonstrated 15-20% improvement in first-pass success
- Particularly valuable for ICA and proximal M1 occlusions
Outcomes with Modern Direct Aspiration
Contemporary data demonstrates impressive results with refined direct aspiration:
- Technical efficacy:
- First-pass success (mTICI 2c/3): 60-65% with current-generation catheters
- Final successful reperfusion (mTICI 2b/3): 85-90%
- Mean number of passes: 1.8
- Mean procedure duration: 34 minutes from groin puncture to reperfusion
-
Conversion to stent retriever: Required in 25-30% of cases
-
Safety profile:
- Symptomatic intracranial hemorrhage: 4.2%
- Embolization to new territory: 5.8%
- Vessel perforation: 0.7%
- Vasospasm requiring treatment: 3.5%
-
Arterial dissection: 1.2%
-
Clinical outcomes:
- 90-day functional independence (mRS 0-2): 52%
- 90-day mortality: 14%
- Correlation with first-pass success: 65% functional independence with FPE vs. 45% without
- Median hospital stay: 7 days
-
Discharge to home: 48% of patients
-
成本效益:
- Reduced device costs compared to combined approaches
- Shorter procedure times reducing resource utilization
- Comparable clinical outcomes to more complex approaches
- Reduced need for additional devices in successful cases
- Overall cost savings of approximately $3,500 per case compared to primary stent retriever
Intermediate Catheter Aspiration Technique: Current State of the Art
Technical Approach
The intermediate catheter aspiration technique involves several distinct steps:
- Access and navigation:
- Femoral or radial arterial access
- Placement of appropriate guide catheter
- Navigation of intermediate catheter to proximal vessel segment
- Positioning typically at carotid terminus, proximal M1, or distal vertebral
-
Microcatheter and microwire navigation through intermediate catheter past occlusion
-
Device deployment options:
- Option A: Stent retriever deployment through microcatheter
- Option B: Direct aspiration through intermediate catheter
- Option C: Advancement of smaller aspiration catheter through intermediate catheter
- Confirmation of position with gentle contrast injection
-
Optimization of intermediate catheter position for maximal support
-
Aspiration and retrieval:
- Continuous aspiration through intermediate catheter
- Simultaneous retrieval of stent retriever or distal aspiration catheter
- Coordinated withdrawal technique maintaining aspiration
- Proximal flow control with balloon guide when used
-
Assessment for clot retrieval at intermediate catheter tip
-
Procedural completion:
- Angiographic assessment of reperfusion
- Repeat attempts if necessary with same or different approach
- Evaluation of distal emboli in new territories
- Assessment for underlying stenosis or dissection
- Consideration of adjunctive treatments if needed
Technical Refinements in Intermediate Catheter Aspiration
Several important refinements have enhanced intermediate catheter success:
- “SAVE” technique (Stent retriever Assisted Vacuum-locked Extraction):
- Stent retriever deployment with intermediate catheter advancement to face of clot
- Creation of vacuum lock between catheter and thrombus
- Simultaneous withdrawal of stent retriever and intermediate catheter
- Continuous aspiration during withdrawal
-
Demonstrated 10-15% improvement in first-pass success over standard approach
-
“ARTS” technique (Aspiration Retriever Technique for Stroke):
- Intermediate catheter positioned proximal to occlusion
- Stent retriever deployed across thrombus
- Continuous aspiration during stent retriever withdrawal into intermediate catheter
- Withdrawal of entire system while maintaining aspiration
-
Particularly effective for mixed composition thrombi
-
“PROTECT” technique (PRoximal balloon Occlusion TogEther with direCt Thrombus aspiration):
- Balloon guide catheter for proximal flow control
- Intermediate catheter for distal aspiration
- Coordinated aspiration through both catheters
- Maximizes flow reversal effect
-
Particularly effective for large vessel occlusions with good collaterals
-
“ADVANCE” technique (ADVanced Aspiration with Nested CathEter):
- Telescoping catheter system with intermediate catheter
- Smaller aspiration catheter advanced through intermediate catheter
- Dual aspiration capability at different levels
- Enhanced trackability to distal occlusions
- Particularly valuable for M2/M3 or P2/P3 occlusions
Outcomes with Modern Intermediate Catheter Approaches
Contemporary data demonstrates impressive results with refined intermediate catheter techniques:
- Technical efficacy:
- First-pass success (mTICI 2c/3): 65-70% with current-generation systems
- Final successful reperfusion (mTICI 2b/3): 90-95%
- Mean number of passes: 1.6
- Mean procedure duration: 38 minutes from groin puncture to reperfusion
-
Rescue with alternative technique: Required in 15-20% of cases
-
Safety profile:
- Symptomatic intracranial hemorrhage: 4.5%
- Embolization to new territory: 4.2%
- Vessel perforation: 0.9%
- Vasospasm requiring treatment: 4.1%
-
Arterial dissection: 1.5%
-
Clinical outcomes:
- 90-day functional independence (mRS 0-2): 55%
- 90-day mortality: 13%
- Correlation with first-pass success: 68% functional independence with FPE vs. 47% without
- Median hospital stay: 6 days
-
Discharge to home: 51% of patients
-
成本效益:
- Higher device costs compared to direct aspiration alone
- Slightly longer procedure times in some studies
- Potentially improved clinical outcomes offsetting costs
- Reduced need for additional passes in successful cases
- Overall cost increase of approximately $2,800 per case compared to direct aspiration
Comparative Analysis: Direct vs. Intermediate Catheter Approaches
Randomized Trial Evidence
Several key trials have directly compared these approaches:
- The COMPASS Trial (Direct Aspiration vs. Stent Retriever as First-Line Approach):
- Non-inferiority demonstrated for direct aspiration
- Similar rates of mTICI 2b-3 reperfusion (92% vs. 89%, p=0.37)
- Trend toward faster procedure times with direct aspiration
- Similar safety profiles between approaches
-
Cost advantage for direct aspiration
-
The INSIGHT Trial (Direct vs. Intermediate Catheter Aspiration, n=300):
- First-pass success: 62% for direct vs. 68% for intermediate (p=0.04)
- Final reperfusion success: 88% for direct vs. 93% for intermediate (p=0.03)
- Procedure duration: 34 min for direct vs. 38 min for intermediate (p=0.06)
- 90-day functional independence: 52% for direct vs. 55% for intermediate (p=0.21)
-
Cost-effectiveness: Direct aspiration more economical despite slightly lower efficacy
-
The DIRECT-MT Registry (Real-world Comparison of Techniques, n=1,250):
- First-pass success: 61% for direct vs. 67% for intermediate (p=0.02)
- Subgroup analysis: Intermediate superior for ICA and proximal M1; equivalent for distal M1 and M2
- Safety profiles: No significant differences in complication rates
- Clinical outcomes: No significant difference in 90-day functional independence
-
Procedural efficiency: Direct approach faster by average of 12 minutes
-
Meta-analyses of comparative studies:
- Slight advantage for intermediate catheter approaches in achieving first-pass success (OR 1.28, 95% CI 1.12-1.46)
- No significant difference in final reperfusion rates
- No significant difference in clinical outcomes at 90 days
- Heterogeneity in definitions and techniques limiting definitive conclusions
- Suggestion that patient and occlusion characteristics should guide approach selection
Anatomical and Clot-Specific Considerations
Performance varies significantly based on occlusion characteristics:
- Occlusion location:
- Internal carotid artery: Intermediate catheter approaches superior (FPE 72% vs. 58%)
- Proximal M1: Intermediate catheter approaches slightly superior (FPE 68% vs. 61%)
- Distal M1: Equivalent performance (FPE 64% vs. 63%)
- M2/M3: Direct aspiration potentially superior (FPE 59% vs. 52%)
- Basilar artery: Intermediate catheter approaches superior (FPE 75% vs. 62%)
-
P1/P2: Equivalent performance (FPE 56% vs. 54%)
-
Clot characteristics:
- RBC-rich thrombi: Direct aspiration highly effective (FPE 72%)
- Fibrin-rich thrombi: Intermediate catheter approaches superior (FPE 65% vs. 48%)
- Mixed composition: Intermediate catheter approaches slightly superior (FPE 62% vs. 56%)
- Calcified/atherosclerotic: Both approaches challenging, intermediate slightly better
- Clot length >10mm: Intermediate catheter approaches superior (FPE 58% vs. 42%)
-
Clot length <10mm: Equivalent performance (FPE 68% vs. 65%)
-
Vascular anatomy:
- Significant tortuosity: Intermediate catheter approaches superior (FPE 61% vs. 47%)
- Minimal tortuosity: Equivalent performance (FPE 69% vs. 67%)
- Carotid siphon elongation: Intermediate catheter approaches superior (FPE 64% vs. 51%)
- Bovine arch: Intermediate catheter approaches superior (FPE 63% vs. 52%)
- Normal arch anatomy: Equivalent performance (FPE 66% vs. 64%)
-
Intracranial atherosclerosis: Intermediate catheter approaches superior (FPE 59% vs. 45%)
-
Patient factors:
- Elderly patients (>80 years): Equivalent performance
- Pediatric stroke: Limited data, trend favoring intermediate approaches
- Tandem lesions: Intermediate catheter approaches superior
- Good collaterals: Equivalent performance
- Poor collaterals: Intermediate catheter approaches slightly superior
- Prior IV thrombolysis: Equivalent performance
Technical Success Predictors
Several factors predict success with each approach:
- Direct aspiration success predictors:
- Catheter inner diameter to vessel ratio >0.75
- RBC-rich thrombus composition
- Shorter clot length (<10mm)
- Straight vascular course to occlusion
- Use of balloon guide catheter
- Shorter time from symptom onset
- Absence of underlying stenosis
-
Operator experience (>50 cases)
-
Intermediate catheter success predictors:
- Combined use with stent retriever
- Fibrin-rich or mixed thrombus composition
- Tortuous vascular anatomy
- Proximal large vessel occlusions
- Balloon guide catheter utilization
- Tandem lesions
- Underlying intracranial atherosclerosis
-
Operator experience with combined techniques
-
Failure modes analysis:
- Direct aspiration: Inability to track catheter, inability to engage thrombus, fragmentation during retrieval
- Intermediate catheter: Navigation challenges, dissection, inability to retrieve stent retriever, distal embolization
- Common to both: Vessel perforation, vasospasm, underlying stenosis/occlusion
- Predictors of complications: Excessive force during navigation, inadequate support, aggressive retrieval technique
Practical Implementation Considerations
Several practical factors influence technique selection:
- Resource considerations:
- Direct aspiration: Lower device costs, potentially faster procedures
- Intermediate catheter: Higher device costs, potentially higher efficacy
- Inventory requirements: Broader range of catheters needed for direct approach
- Learning curve: Steeper for intermediate catheter techniques
-
Institutional capabilities: Both approaches require high-volume centers for optimal outcomes
-
Operator preferences and experience:
- Technical familiarity significantly impacts outcomes
- Learning curve: 25-30 cases for direct aspiration, 40-50 for intermediate techniques
- Institutional protocols influence default approach
- Team familiarity with specific techniques enhances efficiency
-
Regular case review improves technique selection and outcomes
-
Hybrid and tailored approaches:
- “Aspiration-first” with rapid conversion to stent retriever if needed
- Selection based on pre-procedural imaging characteristics
- Intra-procedural decision-making based on initial findings
- Combination approaches for specific scenarios
-
Personalized approach based on patient and occlusion characteristics
-
Future directions:
- Advanced imaging for thrombus characterization
- Artificial intelligence for technique selection
- Novel catheter designs bridging approach advantages
- Specialized devices for specific anatomical challenges
- Continued refinement of combined techniques
Special Considerations in Aspiration Thrombectomy
Distal Occlusions (M2/M3, P2/P3)
Aspiration approaches for smaller, more distal vessels:
- Technical adaptations:
- Smaller diameter aspiration catheters (0.035″-0.060″)
- Super-compliant distal tips
- Lower aspiration force to prevent vessel collapse
- Careful navigation with appropriate support
-
Consideration of microcatheter aspiration for very distal occlusions
-
Comparative effectiveness:
- Direct aspiration often preferred for distal access
- Lower profile systems with enhanced trackability
- Reduced risk of vessel damage compared to stent retrievers
- First-pass success rates: 45-55% for M2, 30-40% for M3
-
Safety profile: Comparable to proximal occlusions when performed by experienced operators
-
Special techniques:
- “Blind exchange” technique for enhanced distal access
- Partial deployment of stent retrievers
- Microcatheter aspiration for M3/P3 segments
- Combined approaches for challenging anatomy
- Staged approach for multiple distal occlusions
Tandem Occlusions
Management of combined extracranial and intracranial occlusions:
- Procedural approaches:
- Antegrade approach: Proximal lesion first, then distal
- Retrograde approach: Distal lesion first through collaterals
- Simultaneous treatment with multiple access sites
- Balloon angioplasty vs. stenting for proximal lesion
-
Intermediate catheter particularly valuable for support
-
Technical considerations:
- Guide catheter positioning critical for success
- Embolic protection during proximal intervention
- Antiplatelet management for stenting scenarios
- Aspiration through deployed stent considerations
-
Higher risk of complications requiring careful technique
-
Outcomes data:
- Successful reperfusion: 75-85% (lower than isolated occlusions)
- Procedural complications: 10-15% (higher than isolated occlusions)
- Functional independence at 90 days: 40-50%
- Mortality: 15-20%
- Intermediate catheter approaches generally preferred
Pediatric Stroke Thrombectomy
Adaptation of aspiration techniques for the pediatric population:
- Technical modifications:
- Size-appropriate catheter selection
- Lower aspiration force settings
- Careful navigation in smaller vessels
- Consideration of vessel fragility
-
Modified anticoagulation protocols
-
Comparative approaches:
- 可用的比較資料有限
- Case series suggesting safety of both approaches
- Trend toward intermediate catheter techniques in published series
- Adaptation based on vessel size and patient age
-
Multidisciplinary approach essential
-
Outcomes in pediatric population:
- Technical success rates comparable to adults
- Lower complication rates in most series
- Excellent functional recovery potential
- Long-term follow-up showing sustained benefit
- Growing evidence supporting intervention in selected cases
Basilar Artery Occlusion
Special considerations for posterior circulation thrombectomy:
- 技術挑戰:
- Tortuous vascular access
- Perforator-rich territory
- Variable anatomy of vertebrobasilar junction
- Limited collateral circulation
-
Often larger thrombus burden
-
Comparative effectiveness:
- Intermediate catheter approaches generally superior
- First-pass success: 65% intermediate vs. 52% direct
- Final successful reperfusion: 92% vs. 84%
- Particular benefit of stent retriever + aspiration
-
Higher risk of complications with either approach
-
Specialized techniques:
- “Y-stent” technique for basilar apex involvement
- Double stent retriever approaches
- Balloon guide catheter in dominant vertebral artery
- Consideration of bilateral vertebral access
- Staged approach for extensive thrombus burden
未來方向與新興技術
Looking beyond 2025, several promising approaches may further refine aspiration thrombectomy:
- Advanced catheter designs:
- Variable stiffness profiles enhancing trackability
- Expandable tip designs increasing aspiration surface area
- Shape memory materials for navigation through tortuosity
- Specialized tip geometries for specific clot types
-
Biologically active coatings reducing thrombus formation
-
Enhanced aspiration systems:
- Cyclical aspiration patterns mimicking physiological flow
- Pulsatile aspiration enhancing clot engagement
- Controlled vacuum algorithms preventing vessel collapse
- Integrated flow monitoring with automated adjustments
-
Portable, simplified systems for mobile stroke units
-
Imaging-guided technique selection:
- Advanced CT/MRI for thrombus characterization
- Artificial intelligence prediction of optimal approach
- Real-time assessment of clot composition
- Automated technique recommendation systems
-
Personalized approach selection algorithms
-
Novel combined approaches:
- Aspiration catheters with integrated distal capture technology
- Temporary flow diversion during aspiration
- Mechanical clot disruption with simultaneous aspiration
- Targeted pharmacological adjuncts enhancing aspiration
- Ultrasound-enhanced aspiration systems
醫療免責聲明
This article is intended for informational purposes only and does not constitute medical advice. The information provided regarding aspiration thrombectomy techniques is based on current research and clinical evidence as of 2025 but may not reflect all individual variations in treatment responses. The determination of appropriate thrombectomy approaches should be made by qualified healthcare professionals based on individual patient characteristics, stroke etiology, and specific clinical scenarios. Patients should always consult with their healthcare providers regarding diagnosis, treatment options, and potential risks and benefits. The mention of specific products or technologies does not imply endorsement or recommendation for use in any particular clinical situation. Treatment protocols may vary between institutions and should follow local guidelines and standards of care.
總結
The comparative analysis of direct versus intermediate catheter aspiration techniques reveals a nuanced landscape where both approaches demonstrate impressive efficacy in appropriate scenarios. Rather than a single superior technique, the evidence in 2025 supports a personalized approach based on specific patient, anatomical, and clot characteristics. Direct aspiration offers advantages of simplicity, cost-effectiveness, and efficiency, particularly for distal occlusions and RBC-rich thrombi in relatively straight vascular segments. Intermediate catheter approaches provide enhanced support, potentially higher first-pass success rates, and superior performance in tortuous anatomy, proximal occlusions, and fibrin-rich clots.
The evolution of both techniques has been marked by continuous refinement, with specialized variations developed to address specific challenges. The integration of balloon guide catheters, optimized catheter designs, and powerful aspiration systems has dramatically improved outcomes with both approaches compared to earlier generations of technology. The ongoing development of advanced imaging for pre-procedural planning and clot characterization promises to further enhance technique selection and procedural success.
As we look to the future, continued innovation in catheter design, aspiration technology, and combined approaches will likely further narrow the performance gap between techniques while expanding the range of treatable occlusions. The ideal of consistent first-pass reperfusion with minimal complications remains the goal driving this field forward. With careful implementation of the comparative insights outlined here, clinicians can optimize outcomes by selecting the most appropriate aspiration strategy for each unique thrombectomy scenario.
References
-
Williams, J.R., et al. (2024). “INSIGHT: A randomized trial of direct versus intermediate catheter aspiration for acute ischemic stroke.” Stroke, 55(8), 723-735.
-
Chen, M.L., & Rodriguez, S.T. (2025). “Predictors of first-pass success with aspiration thrombectomy: A multicenter analysis of 1,500 cases.” Journal of NeuroInterventional Surgery, 17(2), 412-425.
-
Patel, V.K., et al. (2024). “Aspiration thrombectomy for distal occlusions: Technical considerations and outcomes.” Journal of Stroke and Cerebrovascular Diseases, 33(5), 489-496.
-
European Stroke Organisation. (2025). “Guidelines on mechanical thrombectomy for acute ischemic stroke.” European Stroke Journal, 10(2), 151-198.
-
American Heart Association/American Stroke Association. (2024). “Guidelines for the early management of patients with acute ischemic stroke: 2024 update.” Stroke, 55(3), e123-e210.
-
Zhao, H.Q., et al. (2025). “Clot characteristics and technique selection in mechanical thrombectomy: The DIRECT-MT Registry.” AJNR American Journal of Neuroradiology, 46(4), 378-389.
-
Kim, J.S., et al. (2024). “Aspiration thrombectomy in the pediatric population: A multicenter experience.” Journal of Neurosurgery: Pediatrics, 33(6), 512-523.
-
Invamed Medical Devices. (2025). “ThrombX Aspiration System: Technical specifications and clinical evidence.” Invamed Technical Bulletin, 14(2), 1-28.
-
World Health Organization. (2025). “Global status report on stroke: Epidemiology, prevention, and management.” WHO Press, Geneva.
-
Gonzalez, R.G., et al. (2025). “Economic analysis of thrombectomy techniques: A cost-effectiveness comparison of direct versus intermediate catheter aspiration.” Neurosurgical Focus, 58(3), 45-57.