Keeper Endovascular Snare by INVAMED is a single-use, sterile device engineered to capture and retrieve intravascular foreign objects, from dislodged stents or guidewire fragments to thrombosis and other undesirable materials in the vascular system. With an innovative loop design and low-profile catheter introduction, the Keeper Snare provides precise control, maximum radial force, and minimized trauma—streamlining procedures in both arterial and venous settings.
Flexible Snare Loop Geometry
- Constructed from high-tensile nitinol or stainless-steel wires in various loop diameters for optimal capture potential.
- Retains shape memory and radial strength even after multiple manipulation cycles, supporting consistent retrieval.
Ergonomic Catheter Delivery
- Low-profile catheter sheath simplifies femoral, radial, or brachial access.
- Catheter tip and snare loop are radiopaque, facilitating fluoroscopic or angiographic visualization and precise target approach.
Enhanced Capture and Control
- The snare loop compresses or expands under operator control, securely gripping foreign bodies or occlusive elements without risk of fragmenting them further.
- A dedicated handle or torque device (depending on model) provides precision in loop rotation and retraction.
Minimally Invasive Retrieval
- Reduces or eliminates the need for open surgical extraction, shortening patient recovery times and lowering complication risks.
- Effective for broken guidewires, catheter fragments, or other intraluminal materials that must be removed promptly to avoid embolization or vascular injury.
Broad Range of Indications
- Suitable for arterial or venous retrieval in peripheral vessels, central vasculature, or even select cardiac chambers if indicated.
- Helpful in addressing intravascular coil misplacements, filter retrievals, or spontaneous foreign body presence.
產品規格
規格 | 細節 / 價值 |
產品名稱 | Keeper 血管內卡環 |
預期用途 | Retrieval of foreign bodies, dislodged stents, or thrombus fragments from vascular lumens |
Snare Material | Nitinol or Stainless Steel loop with radiopaque marker |
Loop Diameter Range | ~2–35 mm (depending on vessel size) |
Shaft Length | 80–120 cm (various) |
導線相容性 | 0.018” or 0.035” (check model) |
Sheath Compatibility | 4–6F typical |
無菌 | 無菌,單次使用 |
保質期 | ~3 years, 15–25 °C storage |
訂購與尺寸表
Loop Diameter (mm) | Shaft Length (cm) | Guidewire Size | 產品編號 |
5 | 80 | 0.018" | KEE-5-80-018 |
10 | 80 | 0.018" | KEE-10-80-018 |
15 | 100 | 0.035" | KEE-15-100-035 |
20 | 100 | 0.035" | KEE-20-100-035 |
25 | 120 | 0.035" | KEE-25-120-035 |
35 | 120 | 0.035" | KEE-35-120-035 |
相關商品
-
Atlas 主動脈鈦合金支架
查看內容A 自我膨脹 設計用於 大動脈 病變覆蓋,維持 靈活 徑向力以穩定錨定在 胸腔 或 腹部 主動脈解剖。
-
Hero 激光除鉛系統
查看內容A 雷射式 萃取裝置 精密 和 保險 移除 心導線 (起搏器或 ICD)感染、導線故障或升級的情況。
-
InWIRE 0.014" & 0.018" CTO 導線
查看內容一系列 高性能 提供導線 耐用 鈦合金或 不銹鋼 核心、親水塗層和多種噴嘴形狀,可穿透 鈣化 或 複雜 冠狀動脈與周邊病變。
-
Extender 藥物洗淨 PTA 球囊導管
查看內容Extender 藥物洗脫 PTA 球囊導管;A 塗藥 球囊用於周邊血管成形術 (PTA),釋放 抗增殖 藥劑,以減輕股動脈或膕膕動脈的再狭窄。