The Dolphin Sub-Intimal Entry Catheter, by Invamed—a global medical device manufacturer—is uniquely designed to assist in subintimal dissection and re-entry in chronic total occlusions (CTOs) or heavily diseased vascular segments. By providing a targeted pathway to the subintimal space and then guiding re-entry into the true lumen, Dolphin enhances procedural success in complex peripheral or coronary interventions.
Dedicated Subintimal Navigation
Engineered tip or “needle” design helps negotiate the subintimal plane, enabling operators to bypass occlusive lesions.
True Lumen Re-Entry
Specialized distal tip geometry assists in precision re-entry to the true lumen, improving success rates in otherwise intractable CTOs.
High Pushability & Torque
Braided or coiled shaft construction delivers robust force transmission for crossing tough plaque or calcifications.
Hydrophilic Coating (optional)
Minimizes friction against vessel walls, reducing dissection risk and procedural time in challenging anatomies.
Wide Clinical Utility
Indicated for peripheral artery disease (PAD) with occlusive lesions, especially superficial femoral or popliteal arteries. May also be adapted for select coronary interventions.
禁忌症
Extremely tortuous vessels, advanced dissection risk, or patient conditions that preclude subintimal techniques.
一般產品規格
規格 | 細節 / 價值 |
產品名稱 | Dolphin 近端進入導管 |
預期用途 | Facilitates subintimal dissection and re-entry in chronic total occlusion (CTO) or heavily diseased vessels (peripheral or coronary) |
導管設計 | Specially shaped distal tip or “re-entry” needle to access the true lumen from a subintimal plane |
材質 | Pebax/Polyamide shaft with braided reinforcement, possible radiopaque or tungsten tip |
Outer Diameter (Fr) | ~2.0–3.5 Fr for coronary or ~3.5–4.5 Fr for peripheral usage (adjust as appropriate) |
內腔 | Typically 0.014” guidewire compatibility |
工作長度 | ~80–150 cm (varies by product code) |
提示配置 | Tapered, angled, or “needle” re-entry tip, radiopaque marker for precise subintimal guidance |
Marker Bands | 1–2 near the distal segment for fluoroscopic visualization |
Sheath Compatibility | 4F–6F (small coronary variants), 5F–7F (peripheral variants) |
無菌 | 無菌(環氧乙烷) |
單次使用 | 是 |
保質期 | ~2–3 years if stored in sealed packaging at 15–25 °C |
臨床適應症 | Re-entering true lumen in CTOs, subintimal approach in peripheral arteries (e.g., superficial femoral), or advanced coronary CTO crossing |
禁忌症 | Extremely tortuous or heavily calcified vessels, known device material allergies, or situations unsuited for subintimal strategy |
Dolphin 近端進入導管
Fr Size | 工作長度(公分) | Tip Style | 產品編號 | 注意事項 |
2.0 Fr | 80 | Tapered (Needle Tip) | DOL-SI-2.0-80-TP | Ultra-low profile for coronary subintimal re-entry |
2.0 Fr | 100 | Angled Needle | DOL-SI-2.0-100-AN | Slightly angled tip, moderate length |
2.3 Fr | 80 | Straight “Re-Entry” | DOL-SI-2.3-80-ST | Balanced OD for small peripheral or coronary usage |
2.3 Fr | 135 | Tapered (Needle Tip) | DOL-SI-2.3-135-TP | Extended length, deeper CTO crossing |
2.6 Fr | 100 | Angled “Re-Entry” | DOL-SI-2.6-100-AN | Mid-range OD plus angled tip for subintimal SFA approach |
2.6 Fr | 135 | Straight “Re-Entry” | DOL-SI-2.6-135-ST | Long length for complicated multi-segment occlusions |
3.0 Fr | 100 | Tapered (Needle Tip) | DOL-SI-3.0-100-TP | Slightly larger OD for peripheral subintimal re-entry |
3.0 Fr | 135 | Angled “Re-Entry” | DOL-SI-3.0-135-AN | Extended length, angled tip for advanced re-entry strategy |
3.5 Fr | 100 | Straight Needle | DOL-SI-3.5-100-ST | Larger OD for robust push in heavily calcified vessels |
3.5 Fr | 135 | Tapered (Needle Tip) | DOL-SI-3.5-135-TP | Max length for tall patients or extensive subintimal navigation |
4.0 Fr | 135 | Angled “Re-Entry” | DOL-SI-4.0-135-AN | (If your line extends to 4.0 Fr or beyond for large peripheral usage) |
相關商品
-
Extender 紫杉醇藥物洗淨 PTCA 球囊導管
查看內容A 紫杉醇塗層 冠狀動脈球囊導管,旨在 減少再狭窄 在經皮冠狀血管成形術 (PTCA) 期間,可確保有效地將藥物輸送到血管壁。
-
InWIRE 周邊導線
查看內容多種 外周 線配置(親水、硬質、交換長度)有助於 保險 穿越複雜或鈣化的病變,並確保穩定的裝置支撐。
-
Atlas 不銹鋼冠狀動脈支架系統
查看內容A 不銹鋼 冠狀動脈支架產品 穩健 結構完整性和 輕鬆 適用於常規經皮冠狀動脈介入術 (PCI),兼顧成本效益與可靠效能。
-
AngioGraphic 歧管
查看內容A 旋轉 或 方向性 專門用於 斑塊切除 在外周動脈中,可增加 流明 恢復,同時將氣壓創傷降至最低。