The Spider™ Peripheral Detachable Coil System in its detachable pushable configuration is engineered by Invamed—a global medical device manufacturer—to address peripheral aneurysm occlusion, vascular malformations, or fistulae requiring controlled coil placement. By offering a pushable yet detachable delivery mechanism, Spider™ affords the precision of in-place detachment without the complexity of electrolytic release, optimizing procedural control and reducing risk of coil migration.
Detachable Pushable Delivery
Combines the ease of a pushable coil insertion with the detachment control typically associated with mechanical or electrolytic systems, enabling safe retrieval or repositioning before final deployment.
Platinum Coil
High radiopacity ensures real-time fluoroscopic monitoring, helping interventionalists confirm accurate coil positioning and packing density.
Soft & Conformable
The flexible coil design adapts to complex vessel anatomies or aneurysmal sacs, minimizing stress on fragile vessel walls.
Versatile Embolization
Ideal for small-to-moderate peripheral aneurysms, arteriovenous malformations (AVMs), or abnormal vascular communications, delivering precise occlusion.
適應症
Aneurysm repair (e.g., peripheral, visceral), AVM or fistula occlusion in peripheral territories, or general endovascular procedures requiring dense coil packing.
禁忌症
Vessels too small or tortuous to pass the delivery catheter, active infection at the access site, or scenarios where coil retrieval is not feasible.
產品規格
規格 | 細節 / 價值 |
產品名稱 | Spider Peripheral Detachable Coil System |
預期用途 | Endovascular embolization of peripheral aneurysms, AV fistulas, or abnormal vessels |
Coil Material | Platinum or platinum-tungsten alloy with detachable mechanism |
Detachment Method | Mechanical or electrolytic (verify final model) |
Coil Diameter Range | ~1.5–20 mm (varies by catalog code) |
Coil Length Range | ~1–40 cm (depending on coil diameter and framing vs. filling type) |
Delivery Microcatheter | Typically 2.3–2.7F inner diameter, 0.016–0.021” ID |
放射能力 | Platinum coil for fluoroscopic visualization |
無菌 | 無菌,單次使用 |
保質期 | ~3–5 years at 15–25 °C |
臨床適應症 | Peripheral aneurysm occlusion, AVF closure, selective vessel sacrifice |
禁忌症 | Vessels too small or tortuous to accommodate microcatheter, known device material allergies |
訂購與尺寸表
Coil Diameter (mm) | Coil Length (cm) | Detachment Type | 產品編號 | 注意事項 |
1.5 | 2 | Mechanical | SPD-P-1.5x2-M | Very small coil for micro-aneurysms |
1.5 | 4 | Electrolytic | SPD-P-1.5x4-E | Extended length, small diameter |
3.0 | 10 | Mechanical | SPD-P-3.0x10-M | Mid-range coil diameter, framing type |
3.0 | 15 | Electrolytic | SPD-P-3.0x15-E | Longer filling coil for larger sac |
5.0 | 15 | Mechanical | SPD-P-5.0x15-M | Medium coil for moderate aneurysms |
5.0 | 20 | Electrolytic | SPD-P-5.0x20-E | Extended coil length, filling type |
10.0 | 20 | Mechanical | SPD-P-10.0x20-M | Larger diameter coil for bigger aneurysms |
10.0 | 40 | Electrolytic | SPD-P-10.0x40-E | Maximum length coil for large-volume occlusion |
相關商品
-
MultiBEAM Embolization Plug
查看內容A multisided plug device for 血管 或 aneurysmal occlusion, achieving reliable 栓塞 in peripheral or saccular expansions with minimal migration.
-
VeinOFF 靜脈曲張治療劑
查看內容專門 硬化劑 或 膠黏劑 配方,旨在 非熱 消除靜脈曲張,只需最低限度的麻醉和最短的手術時間。
-
NeuroFill
查看內容精密液體栓塞治療 AVM、動脈瘤和神經血管異常。
-
Filler 氰基丙烯酸酯栓塞劑
查看內容A 氰基丙烯酸酯 栓塞用黏合劑 血管 或 AVM 閉塞,提供 快速 與血液接觸後聚合,確保血管密封性穩定,並將假影減至最低。