的 Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.
Leaf Tip Design
- The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
- Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
Nitinol Shaft with PA/PEBAX
- High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
- Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
Radiopaque Shaft Markings
- Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
- Facilitates accurate positioning and ensures confident navigation through complex vascular pathways.
Flexible Catheter Profiles
- Available in 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
- Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.
Multiple Catheter Lengths
90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.
產品規格
規格 | 細節 / 價值 |
產品名稱 | Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration |
預期用途 | Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems |
導管設計 | Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal |
材質 | Stainless steel or nitinol drive shaft, flexible polymer outer sheath |
Rotational Speed Range | ~40k–80k rpm (check final specs) |
Aspiration Mechanism | Over-the-wire suction or integrated vacuum line |
Catheter Outer Diameter | ~5–7F, depending on model and tip size |
工作長度 | ~80–120 cm (varies by product code) |
放射能力 | Distal marker near leaf tip for precise positioning under fluoroscopy |
無菌 | 無菌,單次使用 |
保質期 | ~2–3 years at 15–25 °C |
臨床適應症 | Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT) |
禁忌症 | Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials |
訂購與尺寸表
外徑 (F) | 工作長度(公分) | Leaf Tip Diameter (mm) | 產品編號 | 注意事項 |
5F | 80 | 5 | MNT-LF-5F-80-5 | Smaller tip for distal or smaller vessels |
5F | 100 | 5 | MNT-LF-5F-100-5 | Longer shaft, same leaf diameter |
6F | 80 | 6 | MNT-LF-6F-80-6 | Common size for peripheral artery usage |
6F | 120 | 6 | MNT-LF-6F-120-6 | Extended length for deeper or proximal segments |
7F | 100 | 7 | MNT-LF-7F-100-7 | Larger leaf tip for heavier thrombus loads |
7F | 120 | 7 | MNT-LF-7F-120-7 | Max length and larger tip for extensive clot burden |
相關商品
-
Mantis CURVE Over-the-Wire (OTW) 旋轉式藥物機械血栓切除系統
查看內容顏色 通过电线 (OTW) 裝置合併 旋轉 與 藥物 溶解,有效清除大型血栓,同時保護健康的血管壁。
-
Extender PTCA 球囊導管
查看內容A 標準 高壓 冠狀動脈球囊 專為 病變預防 或獨立 血管成形術提供精確的充氣輪廓和較少的交叉輪廓。
-
AngioHAND 血塊移除導管
查看內容A 手操 機械抽吸裝置,可立即 凝塊提取 通過 手冊 真空方式,簡化急性血栓切除手術。
-
Viper™ 帶閥輸液導管
查看內容的 Viper™ 帶閥輸液導管 是一個 單腔, 閥嘴 交付系統,可靈活 泡水 抗血栓形成劑、不透光造影劑或其他醫師指定的藥物溶液 與 或 橆 將導絲安裝到位。