DolphinPro Support Catheter
A crossing support catheter for 複雜 peripheral or coronary lesions, featuring a reinforced shaft 和 hydrophilic coating to ease device delivery.
DolphinPro Support Catheter by Invamed is specifically engineered to cross complex lesions in difficult anatomies during femoro-popliteal and below-the-knee procedures. Its robust stainless steel double-braiding ensures a kink-resistant design with exceptional torque control, allowing seamless navigation through tortuous vessels. By featuring a small crossing profile, DolphinPro delivers unparalleled support and pushability, facilitating successful lesion crossing and enabling telescope technique in endovascular interventions.
Stainless Steel Double-Braiding
A unique multi-layer shaft construction combines kink resistance with dynamic torque control, providing stable maneuverability even in challenging anatomical routes.
Optimal Push Transition
Seamlessly transfers applied force from the proximal shaft to the distal tip, aiding clinicians in tackling complex, heavily calcified or eccentric lesions without compromising on control.
Small Crossing Profile
Minimizes friction and vessel trauma, improving guidewire-to-catheter transitions. This design optimizes trackability within narrow below-the-knee vessels or severe occlusive segments.
Telescope Technique
DolphinPro’s flexible distal segment and supportive proximal section facilitate telescope approach, helping operators reach distal lesions and perform targeted interventions under precise control.
Broad Clinical Utility
Ideal for femoro-popliteal occlusions, tibioperoneal blockages, or challenging SFA lesions, where high pushability and low-profile crossing are crucial to procedural success.
禁忌症
- Extreme vessel tortuosity or diameter below specification
- Active infection or severe vessel dissection precluding wire-based recanalization
- Patient conditions contraindicating endovascular procedures
Technical Specifications
規格 | 細節 / 價值 |
產品名稱 | DolphinPro Support Catheter |
預期用途 | Lesion crossing and support in femoro-popliteal & BTK interventions |
Shaft Construction | Stainless Steel Double-Braiding with advanced polymer coatings |
Proximal Diameter | Low-profile crossing design; verify available French sizes based on region |
Distal Tip Profile | Tapered, reinforced tip for improved guidewire entry and lesion crossing |
Length Options | Common lengths ranging from 65 cm to 150 cm; additional lengths upon request |
導線相容性 | Typically 0.014” or 0.018” (verify exact compatibility) |
放射能力 | Radiopaque distal tip and markers for precise visualization |
無菌 | Provided sterile (single use) |
臨床適應症 | Chronic total occlusions, tight stenoses, calcific occlusions in fem-pop & BTK vasculature |
Size & Ordering Matrix
French Size | Usable Length (cm) | Guidewire | Tip Shape | 產品編號 | 注意事項 |
2.4 – 2.6 | 65 / 90 / 135 | 0.014” | Straight, Tapered | DPH-2.6-XX-014 | Suited for BTK interventions requiring flexible distal tip and stable proximal support |
2.4 – 2.6 | 100 / 150 | 0.014” | Straight, Tapered | DPH-2.6-XX-014 | Extended length for deeper lesions in SFA or popliteal region |
3.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
4.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
5.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
6.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
7.0 | 80 / 135 / 150 | 0.035" | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
相關商品
-
Dolphin Sub-Intimal Entry Catheter
查看內容A sub-intimal entry system aiding re-entry into the true lumen after sub-intimal crossing in CTO or heavily occluded segments, ensuring minimal dissection expansions.
-
Dolphin ZEBRA Crossing Support Catheter
查看內容專門 ZEBRA-pattern coated support catheter optimizing visibility under fluoroscopy, enabling consistent lesion crossing in 複雜 occlusions.
-
TemREN 外周粥樣斑塊切除系統
查看內容A 旋轉 或 方向性 專門用於 斑塊切除 在外周動脈中,可增加 流明 恢復,同時將氣壓創傷降至最低。
-
Nexus 動靜脈套管
查看內容多用途 靜脈 和 动脉 插管支撐 體外循環 在心肺旁路或 ECMO 期間,確保最佳的 流速 和 血液相容性.