的 Atlas™ Venous Stent, introduced by Invamed—a global medical device manufacturer—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a 自我膨脹 nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting 耐用 patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
禁忌症
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
| 規格 | 細節 / 價值 |
| 產品名稱 | Atlas™ Venous Stent |
| Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
| 部署機制 | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
| 徑向力 | Moderate to high, designed to resist extrinsic compression |
| 支架直徑範圍 | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
| Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
| 不透輻射標記 | Proximal and distal markers for fluoroscopic visualization |
| 無菌 | Sterile, single use |
| 保質期 | ~3–5 years if stored at 15–25 °C |
| 臨床適應症 | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
| Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | 產品編號 | 注意事項 |
| 10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
| 10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
| 14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
| 14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
| 16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
| 16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
| 20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
相關商品
-

Mantis XP Thrombectomy System for Fistula
查看內容A high-powered mechanical thrombectomy device for deep venous or arterial occlusions, supporting extended reach and robust clot extraction in complex anatomies.
-

Dovi 血栓超抽吸導管
查看內容A 高真空 抽吸導管 急性 或 近尖 在動脈或靜脈床移除血栓,確保快速血管再造,並將碎裂風險降至最低。
-

NOD Valvulotome
查看內容A 鈦 或 合金 胸骨接骨板系統提供 死板 胸骨中線切除術後的固定,加強 胸骨穩定性 並降低心臟手術後的感染或開裂風險。
-

Inca Trellis 溶栓系統
查看內容A 導管 交付 溶栓 代理商,而 濾波器 保護功能可防止遠端栓塞,確保更安全的藥理溶解血栓。
