Reinforced Stability, Unparalleled Durability
Elevate Vascular Repair with the Power of Carbon:
• Durability: The carbon coating adds an extra layer of strength and resilience. • Biocompatibility: Designed to minimize irritation and promote faster recovery. • Radiopacity: Enhanced visibility under imaging for precise placement.


Precision, Protection, Performance:
SIGNIFICANT ADVANCEMENT IN ENDOVASCULAR REPAIR TECHNOLOGY
ENHANCED WITH A ROBUST CARBON COATING OPTIMIZED FOR BOTH FLEXIBILITY AND CONFORMABILITY
Self-Expanding Nitinol Framework
- Shape-Memory Alloy: Nitinol’s superelastic properties enable consistent radial force to maintain stent apposition, conforming effectively to vessel anatomies.
- Tantalum Markings: Both stent ends include tantalum markers, providing high radiopacity for precise positioning under fluoroscopy.
Microporous ePTFE Graft Material
- Sealing Function: The ePTFE covering excludes blood flow from the aneurysmal or diseased arterial wall, helping reduce the risk of endoleaks.
- Biocompatible & Low Profile: The microporous structure supports healing while limiting inflammatory responses.
Single-Stent Design
- Straightforward Implantation: Simplifies device selection and deployment, particularly beneficial in peripheral lesions requiring a single stent graft solution.
- Enhanced Device Integrity: Minimizes potential junctional leak points or component separations sometimes encountered in multi-piece stent systems.
Carbon Surface Coating
- Thromboresistant: The carbon coating on the stent struts aims to reduce platelet adhesion, promoting stable device integration and lower incidence of thrombosis.
- Smooth Flow Lumen: Enhances hemodynamic compatibility and may further limit intimal hyperplasia.
Wide Diameter and Length Range
- Stent Graft Size: 5.0 to 10.0 mm diameters address multiple peripheral vessel diameters.
- Nominal Stent Graft Length: Ranging from 18 to 58 mm in designated sizes (18, 22, 28, 38, 58 or 18, 23, 27, 37, 57)—covering a broad spectrum of lesion lengths.
一般產品規格
規格 | 細節 / 價值 |
產品名稱 | Atlas Endovascular Stent Graft |
預期用途 | Endovascular repair of peripheral aneurysms, arterial occlusive disease, or traumatic injuries (iliac, femoral, popliteal) |
Graft Material | ePTFE covering over metal scaffold |
Scaffold Material | Nitinol (self-expanding depending on design) |
Deployment Method | Over-the-wire with introducer sheath (commonly 14F–18F, depending on stent diameter) |
徑向力 | Medium-High, ensuring stable vessel wall apposition |
Delivery Shaft Length | Typically 80–120 cm (verify exact product specs) |
不透輻射標記 | Proximal and distal markers to guide accurate placement |
無菌 | 無菌(環氧乙烷) |
單次使用 | 是 |
保質期 | ~3-5 年,如果在 15-25 °C 密封包裝下儲存 |
MR 相容性 | MR 有條件(驗證標籤) |
臨床適應症 | Peripheral artery aneurysms (iliac, femoral), endoluminal bridging for traumatic or pseudoaneurysms, possible bypass for occlusive lesions |
禁忌症 | Extremely calcified or tortuous vessels preventing safe device passage, known nickel or metal allergies |
Atlas Endovascular Stent Graft
直徑 (mm) | 長度 (mm) | 鞘 Rec. | 產品編號 | 注意事項 |
6 | 40 | ~14F | AESG-6x40 | Small diameter for distal external iliac or femoral |
6 | 60 | ~14F | AESG-6x60 | |
6 | 80 | ~14F | AESG-6x80 | |
7 | 40 | ~14F | AESG-7x40 | Slightly larger for moderate-sized arteries |
7 | 80 | ~14F | AESG-7x80 | |
7 | 100 | ~14F | AESG-7x100 | |
8 | 60 | ~14–16F | AESG-8x60 | Common size for iliac region |
8 | 80 | ~14–16F | AESG-8x80 | |
8 | 120 | ~16F | AESG-8x120 | Longer coverage for extensive lesion |
9 | 60 | ~16F | AESG-9x60 | For large external iliac or superficial femoral |
9 | 100 | ~16F | AESG-9x100 | |
9 | 150 | ~16F | AESG-9x150 | Extended length for multi-segment disease |
10 | 60 | ~16–18F | AESG-10x60 | Larger diameter for bigger femoral or proximal arteries |
10 | 120 | ~18F | AESG-10x120 | |
10 | 150 | ~18F | AESG-10x150 | |
12 | 80 | ~18F | AESG-12x80 | Very large diameter bridging aneurysms |
12 | 100 | ~18F | AESG-12x100 | |
12 | 150 | ~18F | AESG-12x150 | Maximum coverage for extensive peripheral disease |
12 | 200 | ~18F | AESG-12x200 | Very long stent graft for special cases |
相關商品
-
JaGuar 導向鞘
查看內容A 編織 導向鞘提供 扭力 控制和 扭結 安全裝置導航的阻力 外周 或 內臟 干預。
-
Viper™ 帶閥輸液導管
查看內容的 Viper™ 帶閥輸液導管 是一個 單腔, 閥嘴 交付系統,可靈活 泡水 抗血栓形成劑、不透光造影劑或其他醫師指定的藥物溶液 與 或 橆 將導絲安裝到位。
-
Dolphin ZEBRA Crossing Support Catheter
查看內容專門 ZEBRA-pattern coated support catheter optimizing visibility under fluoroscopy, enabling consistent lesion crossing in 複雜 occlusions.
-
Extender 紫杉醇藥物洗淨 PTCA 球囊導管
查看內容A 紫杉醇塗層 冠狀動脈球囊導管,旨在 減少再狭窄 在經皮冠狀血管成形術 (PTCA) 期間,可確保有效地將藥物輸送到血管壁。
















































































聯絡與支援
我們能幫上什麼忙?
在我們開始之前,什麼最能形容您?
聯絡與支援
醫療照護專業人員
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
產品查詢
臨床與研究支援
訓練與教育
技術支援
聯絡與支援
病人與照護者
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
產品使用與安全
訂購與付款
支援與後續照護
聯絡與支援
供應商及經銷商
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
合作夥伴與合約
物流與航運
合規性與文件
聯絡與支援
供應商及經銷商
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
新聞稿與新聞
訪談與聲明
活動與會議
聯絡與支援
其他 / 一般諮詢
線上諮詢表單
若有一般或產品相關問題,請填寫我們的快速線上表格。您將收到確認和參考編號,以便追蹤。
一般資訊
反饋與建議
HeadQuarter 支援專線
- One World Trade Center, 285 Fulton Street.New York, NY 10007, USA
- globalsales@invamed.com
- +1 (347) 535-0630