The AngioHAND Clot Removal Catheter by Invamed is a hand-operated mechanical aspiration system designed to immediately remove thrombi or emboli during acute vascular occlusions. Featuring braided balloon-shaped structures, the catheter actively captures clots and pulls them into the lumen, enabling safe, streamlined thrombectomy without complex capital equipment or continuous vacuum lines. Ideal for distal or proximal arterial/venous clots, AngioHAND simplifies acute stroke, limb ischemia, or DVT management.
Braided Balloon-Shaped Capture
- Expandable mesh or braided balloon segments at the distal tip engage and enclose clot mass, guiding it into the catheter lumen.
- Ensures robust clot entrapment without excessive fragmentation or distal embolization.
Manual Vacuum Mechanism
- Operated by a hand-held syringe-like device or integrated handle, creating a controlled negative pressure to aspirate clot into the catheter shaft.
- Minimizes procedural complexity—no large vacuum pumps—offering immediate aspiration capacity at the bedside or in urgent OR settings.
Rapid & Intuitive Thrombectomy
- Inserted percutaneously via a small arterial or venous access; navigated under fluoroscopic guidance to the occlusion site.
- One-hand manipulation of the aspiration handle triggers vacuum and clot removal in real-time, optimizing speed and efficiency.
Enhanced Safety & Vessel Protection
- Balloon-shaped braids gently expand against the vessel walls, preventing the catheter tip from causing undue trauma.
- Reduces the risk of iatrogenic injuries and maintains patency around the extraction zone for improved patient outcomes.
Multiple Clinical Indications
- Acute ischemic stroke retrieval in cerebral arteries (depending on vessel diameter and regulatory approvals).
- Peripheral arterial occlusions (e.g., acute limb ischemia, popliteal thrombosis) or venous thrombi (DVT).
- Use in emergent or elective procedures where fast mechanical clot extraction is paramount.
產品規格
規格 | 細節 / 價值 |
產品名稱 | AngioHAND 血塊移除導管 |
預期用途 | Manual vacuum-based aspiration of thrombus, emboli, or clot debris in peripheral or coronary vessels |
導管設計 | Hand-operated syringe or vacuum-based system, flexible polymer shaft with a soft distal tip |
外徑範圍 | ~5F–7F (depending on model) |
Lumen Inner Diameter | Large bore optimized for clot aspiration |
工作長度 | ~80–120 cm (varies by product code) |
提示配置 | Tapered or funnel-shaped tip to facilitate clot ingress |
Radiopaque Marker | Distal marker band for fluoroscopic location |
Vacuum Mechanism | Manual hand-syringe or integrated vacuum lock (no external pump required) |
無菌 | 無菌,單次使用 |
保質期 | ~2–3 years at 15–25 °C |
臨床適應症 | Acute clot removal in peripheral arteries/veins, smaller coronary vessels, or bypass grafts |
禁忌症 | Severe vessel tortuosity, extremely large clot burden exceeding device capacity, known device material allergy |
訂購與尺寸表
外徑 (F) | 工作長度(公分) | Tip Style | 產品編號 | 注意事項 |
5F | 80 | Tapered Soft Tip | ANG-HND-5F-80-TS | Smaller diameter for coronary or distal peripheral |
5F | 100 | Funnel Tip | ANG-HND-5F-100-FN | Moderate length, manual vacuum approach |
6F | 80 | Tapered Soft Tip | ANG-HND-6F-80-TS | Common size for peripheral thrombus aspiration |
6F | 120 | Funnel Tip | ANG-HND-6F-120-FN | Extended length for deeper occlusion sites |
7F | 100 | Tapered Soft Tip | ANG-HND-7F-100-TS | Larger lumen for heavier clot burden |
7F | 120 | Funnel Tip | ANG-HND-7F-120-FN | Maximum length plus funnel design for wide clot removal |