ThermoBLOCK Varikoz tomirlarining radiochastota ablasyon tizimi

A radiochastota uchun ablasyon platformasi qobiliyatsiz yuzaki tomirlar, taklif termal yengillashtirish uchun safen yoki teshuvchi tomirlarni yopish varikoz alomatlar.

The Thermal Coagulation RF Ablation Generator hisoblanadi rivojlangan, feedback-driven system designed to deliver high-frequency radiofrequency (RF) energy uchun ThermoBLOCK™ catheters va ThermoBLOCK™ stylets—enabling maqsadli thermal ablation for chronic venous insufficiency (CVI). Equipped with a haqiqiy vaqt monitoring mechanism, the generator precisely regulates intravascular heat parameters, ensuring xavfsiz va consistent power application while protecting surrounding tissues.

Real-Time Feedback Control
  • Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
  • Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
  • Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing va sealing of incompetent veins.
  • Minimal garov zarari: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
  • Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
  • Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
  • ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
  • Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
  • Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
  • Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
  • Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing va sealing of incompetent veins.
  • Minimal garov zarari: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
  • Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
  • Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
  • ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
  • Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.

Mahsulot spetsifikatsiyalari

Spetsifikatsiya Tafsilot / qiymat
Mahsulot nomi ThermoBLOCK Varicose Vein RF Ablation System
Foydalanish maqsadi Endovenous radiofrequency ablation (RFA) of incompetent saphenous or perforator veins
RF Catheter Design 6–7F catheter with electrode segment near distal tip, temperature-controlled
Nominal Power ~10–30 W (depends on vein diameter and system setting)
Catheter Length ~60–120 cm (varies by code)
Generator Compatibility ThermoBLOCK RF Generator or universal 460 kHz system
Temperature Monitoring Integrated thermocouple in ablation segment
Treatment Cycle Typically ~20–40 seconds per segment, auto-regulated by temperature feedback
Sterillik Steril, bir martalik
Yaroqlilik muddati ~2–3 years at 15–25 °C
Klinik ko'rsatmalar Great saphenous vein (GSV) reflux, small saphenous vein, perforator incompetence
Qo'llash mumkin bo'lmagan holatlar Unclear vein anatomy, severe peripheral arterial disease, known intolerance to device materials

Buyurtma va o'lcham matritsasi

Catheter Size (F) Catheter Length (cm) Ablation Segment (cm) Mahsulot kodi Eslatmalar
6F 60 7 TBLK-6F-60-7 Short catheter for small segments
6F 100 7 TBLK-6F-100-7 Standard ablation length, extended shaft
7F 100 10 TBLK-7F-100-10 Longer ablation segment for large GSV trunk
7F 120 10 TBLK-7F-120-10 For taller patients or more extensive reflux
7F 120 15 TBLK-7F-120-15 Extra ablation segment for major trunk veins