Atlas Venous Stent
A specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
The Atlas™ Venous Stent, introduced by Invamed—a global medical device manufacturer—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a o'z-o'zidan kengayish nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting bardoshli patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Qo'llash mumkin bo'lmagan holatlar
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
Spetsifikatsiya | Tafsilot / qiymat |
Mahsulot nomi | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
Joylashtirish mexanizmi | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
Radial kuch | Moderate to high, designed to resist extrinsic compression |
Stent diametri diapazoni | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
Radiopak belgilari | Proximal and distal markers for fluoroscopic visualization |
Sterillik | Sterile, single use |
Yaroqlilik muddati | ~3–5 years if stored at 15–25 °C |
Klinik ko'rsatmalar | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | Mahsulot kodi | Eslatmalar |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
O' turdagi mahsulotlar
-
Inca® Embolism Protective System
BatafsilA catheter delivering thrombolytic agents while filter protection prevents distal embolization, ensuring safer pharmacologic dissolution of clots.
-
Mantis PRO Rotational Thrombectomy & Ultra Aspiration
BatafsilA aylanish system featuring for mechanical clot fragmentation plus strong aspiration capabilities in deep venous or arterial occlusions.
-
VascuVac Ai Assisted Vakuum Trombektomiya Texnologiyalari
BatafsilSamarali vakuumli trombektomiya uchun sun'iy intellekt texnologiyasidan foydalanadigan innovatsion tizim. tromblarni tezda olib tashlash qon tomirlaridan, qon oqimini tiklash, va protsessual risklarni minimallashtirish qon tomir aralashuvlarda.
-
Dovi Thrombus Ultra Aspiration Catheter
BatafsilA high-vacuum aspiration catheter for acute yoki subacute thrombus removal in arterial or venous beds, ensuring rapid revascularization with minimal fragmentation risk.