Fistül için Mantis XP Trombektomi Sistemi
A yüksek güçlü Derin venöz veya arteriyel oklüzyonlar için mekanik trombektomi cihazı, karmaşık anatomilerde genişletilmiş erişim ve sağlam pıhtı ekstraksiyonunu destekler.
Bu Mantis XP bir pharmacomechanical thrombectomy system specifically engineered for dialysis native AV fistulae. Featuring a rotasyonel catheter design and sinusoidal wave geometry, Mantis XP enables rapid ve verimli clot disruption, infusion, and evacuation in a single pass—helping to restore patency while minimize etmek potential vessel trauma in end-stage renal disease (ESRD) patients requiring continuous dialysis access.
Rotational Thrombectomy Mechanism
- Sinusoidal Wave Shape: The unique sinusoidal wire design translates rotational energy into targeted clot fragmentation, limiting stress on native fistula walls.
- Pharmacomechanical Combination: Simultaneously administers lytic agents (if required) via the infusion zone, accelerating clot dissolution and removal.
Extended Infusion Zone
- 10 cm from Distal Tip: Delivers thrombolytic or flushing solutions directly to the lesion area, optimizing pharmacologic contact with the clot.
- Efficient Local Drug Delivery: Improves clot breakdown while minimizing systemic agent usage.
Variable Catheter Length & Profile
- Lengths: 30 cm, 45 cm, 90 cm, 110 cm provide flexibility for short or extended vascular access routes—particularly relevant for complex fistula anatomies.
- Profiles: 5.0F–7.0F outer diameters suit different vessel sizes, ensuring robust torque transmission and navigability.
Nitinol & PA/PEBAX Construction
- Nitinol Core: Maintains shape integrity and provides kink resistance, critical in tortuous AV fistula segments.
- PTFE Inner Layer: Minimizes friction with guidewires and helps protect vessel surfaces during repeated manipulations.
Radiopacity & Visibility
- Braided Shaft: Allows real-time tracking under fluoroscopy, visible from the distal tip için proximal segment.
- 15 cm Active Zone: Clear identification ensures accurate lesion coverage and improved operator confidence.
- Sinusoidal Wave Shape: The unique sinusoidal wire design translates rotational energy into targeted clot fragmentation, limiting stress on native fistula walls.
- Pharmacomechanical Combination: Simultaneously administers lytic agents (if required) via the infusion zone, accelerating clot dissolution and removal.
- 10 cm from Distal Tip: Delivers thrombolytic or flushing solutions directly to the lesion area, optimizing pharmacologic contact with the clot.
- Efficient Local Drug Delivery: Improves clot breakdown while minimizing systemic agent usage.
- Lengths: 30 cm, 45 cm, 90 cm, 110 cm provide flexibility for short or extended vascular access routes—particularly relevant for complex fistula anatomies.
- Profiles: 5.0F–7.0F outer diameters suit different vessel sizes, ensuring robust torque transmission and navigability.
- Nitinol Core: Maintains shape integrity and provides kink resistance, critical in tortuous AV fistula segments.
- PTFE Inner Layer: Minimizes friction with guidewires and helps protect vessel surfaces during repeated manipulations.
- Braided Shaft: Allows real-time tracking under fluoroscopy, visible from the distal tip için proximal segment.
- 15 cm Active Zone: Clear identification ensures accurate lesion coverage and improved operator confidence.
Ürün Özellikleri
Şartname | Detay / Değer |
Ürün Adı | Mantis XP Thrombectomy System |
Kullanım Amacı | High-powered mechanical thrombectomy in venous or arterial occlusions, removing large or organized clot |
Kateter Tasarımı | Rotational shaft with extended reach (“XP”), integrated aspiration lumen or side port |
Malzeme | Stainless steel or nitinol core, polymer outer sheath |
Rotational Speed Range | ~50k–120k rpm (verify final) |
Dış Çap (F) | ~6–8F (depending on model) |
Çalışma Uzunluğu | ~80-120 cm (ürün koduna göre değişir) |
Kılavuz Tel Uyumluluğu | Typically 0.035” |
Sterilite | Steril, Tek Kullanımlık |
Raf Ömrü | 15-25 °C'de kapalı ambalajda saklandığında ~2-3 yıl |
Klinik Endikasyonlar | Large clot burdens in major peripheral veins/arteries, deep venous thrombosis (DVT), acute limb ischemia |
Kontrendikasyonlar | Extremely tortuous vessels, heavily calcified segments, or known sensitivity to device materials |
Sipariş ve Boyut Matrisi
Dış Çap (F) | Çalışma Uzunluğu (cm) | İpucu Yapılandırması | Ürün Kodu | Notlar |
6F | 80 | Standard Rotational Tip | MNT-XP-6F-80-SR | Smaller OD for moderate clot loads |
6F | 100 | Leaf Tip | MNT-XP-6F-100-LF | Intermediate length, specialized tip for large clot |
7F | 80 | Standard Rotational Tip | MNT-XP-7F-80-SR | Larger OD for heavier clot burden |
7F | 120 | Leaf Tip | MNT-XP-7F-120-LF | Extended shaft + specialized tip for extensive occlusions |
8F | 100 | Standard Rotational Tip | MNT-XP-8F-100-SR | Max diameter & high rotational power for dense clots |
8F | 120 | Leaf Tip | MNT-XP-8F-120-LF | Extended length + leaf tip for severe multi-segment thrombosis |
İlgili ürünler
-
Mantis PRO Rotasyonel Trombektomi ve Ultra Aspirasyon
Devamını okuA rotasyonel için özellikli sistem mekanik pıhtı parçalanması artı güçlü Derin venöz veya arteriyel oklüzyonlarda aspirasyon yetenekleri.
-
NOD Valvulotom
Devamını okuA titanyum veya alaşım sağlayan sternal plak sistemi katı orta hat sternotomi sonrası fiksasyon, güçlendirici sternal stabilite ve kalp cerrahisi sonrası enfeksiyon veya dehisans risklerini azaltmak.
-
Atlas Venöz Stent
Devamını okuDamar açıklığını koruyarak, kan akışını iyileştirerek ve kronik venöz yetmezlik semptomlarını hafifleterek venöz tıkanıklıkları tedavi etmek için tasarlanmış, biyouyumlu metal alaşımlardan yapılmış özel bir implant sistemi.
-
VeinOFF Varis Tedavi Maddesi
Devamını okuBir uzman sklerozan veya yapışkan hedefleyen formül termal olmayan varis eliminasyonu, minimal anestezi ve kısa işlem süresi gerektirir.