Mfumo wa Kufunga Mshipa wa Venablock ™ Varicose Veins
Mfumo wa Kufunga Mshipa wa Venablock ™ Varicose Vena; A msingi wa cyanoacrylate mfumo wa kufungwa kwa mshipa ya juu juu kutokuwa na uwezo wa venous, kujifungua yasiyo ya joto kuziba na anesthesia ndogo ya ndani na haraka kupona baada ya utaratibu.
Venablock ™ Varicose Veins Treatment Vein Closure System —often referred to internationally as “Turkish Glue”—is an innovative, minimally invasive solution for varicose vein management. By leveraging a unique cyanoacrylate-modified polymer that rapidly polymerizes in under one second, VenaBlock seals the insufficient vein segment with remarkable efficiency and negligible risk of embolic complications. Clinical publications report a success rate of around 96%, making VenaBlock a breakthrough in modern venous ablation therapy.
Ultra-Fast Polymerization
The cyanoacrylate-based polymer reaches full set in <1 second, enabling precise vein closure with minimal risk of distal embolization.
Laser Guidance (630 nm Red Light)
A red laser (630 nm) is integrated into the catheter shaft to improve visibility and tracking under procedural imaging. This feature dramatically streamlines catheter navigation through tortuous venous segments.
No Guidewire Necessity
Thanks to superior kink resistance and radial-tip design, VenaBlock can be advanced through curved varicose veins without a dedicated guidewire, reducing procedural complexity.
Minimal Invasive Technique
The procedure typically completes within a short timeframe. In many cases, applying 1-second compressions every ~10 cm along the target vein is sufficient to achieve rapid sealing.
High Kink Resistance
Constructed with a PTFE Teflon-braided catheter shaft (6F, 5F, or 4F options), it remains flexible yet strong, navigating tortuous veins without risk of collapse or excessive friction.
Proximity to SFJ
The catheter can safely ablate varicose veins within 0.5 cm of the saphenofemoral junction (SFJ). By controlling venous closure so close to the SFJ, VenaBlock effectively reduces the risk of incomplete occlusion or recurrences.
Tremendous Safety
With under-one-second polymerization near the SFJ, any significant risk of embolization is significantly minimized—a cornerstone for patient safety.
Minimally Invasive
Allows outpatient procedures with local anesthesia, minimal post-procedural pain, and quick return to daily activities.
Single-Catheter Efficiency
The radial-tip design and kink-resistant shaft help traverse tortuous veins without a guidewire.
Immediate Vein Closure
Ultra-fast polymerization means reliable occlusion from the SFJ downward, minimizing recanalization.
Reduced Embolization Risk
Rapid set time (<1 second) near SFJ drastically limits potential embolic events.
Greater Patient Comfort
Eliminates the thermal pain associated with lasers or radiofrequency devices, while still ensuring high efficacy.
Vipimo vya Bidhaa
Vipimo | Maelezo / Thamani |
Jina la Bidhaa | VenaBlock™ Vein Sealing System |
Catheter Material | PTFE Teflon-braided shaft (kink-resistant) |
Catheter Sizes | 6F, 5F, 4F (customizable to different vein diameters) |
Catheter Length | ~90 cm (standard) |
Inner Lumen Diameter | ~0.6 mm ID |
Integrated Laser | 630 nm red laser for enhanced positioning/visibility |
Sealing Agent | Modified Cyanoacrylate Polymer; rapid polymerization within 1 second |
Application Method | Minimal compressions (~1 second each) every 10 cm along target vein |
Clinical Success Rate | ~96% based on reported clinical data |
Viashiria | Great saphenous vein (GSV) insufficiency, varicose veins in lower extremities, or incompetent perforators |
Contraindications | Active local infection at insertion site, extremely small vein diameter preventing safe catheter insertion |
Matrix ya Kuagiza & Ukubwa
Catheter Size (F) | Catheter Length (cm) | Adhesive Volume (mL) | Kanuni ya Bidhaa | Vidokezo |
4F | 60 | 1.0 | VBL-4F-60-1.0 | Short length for small segments |
4F | 100 | 1.5 | VBL-4F-100-1.5 | Longer catheter for GSV trunk |
5F | 60 | 1.0 | VBL-5F-60-1.0 | Slightly larger ID, short approach |
5F | 100 | 2.0 | VBL-5F-100-2.0 | Larger adhesive volume for extended reflux segments |
6F | 100 | 3.0 | VBL-6F-100-3.0 | High-volume adhesive for multiple varicose branches |
Bidhaa zinazohusiana
-
VeinOFF Wakala wa Matibabu ya Mshipa wa Varicose
Soma zaidiA maalumu sclerosant au wambiso formula inayolenga yasiyo ya joto kuondolewa kwa mishipa ya varicose, inayohitaji anesthesia ndogo na muda mfupi wa utaratibu.
-
Extender PTCA Balloon Catheter
Soma zaidiA standard high-pressure coronary balloon iliyoundwa kwa ajili ya lesion predilation or standalone angioplasty, offering precise inflation profiles and reduced crossing profiles.
-
Viper™ Valved Infusion Catheters
Soma zaidiThe Viper™ Valved Infusion Catheter ni a single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with au without a guidewire in place.
-
Atlas Venous Stent
Soma zaidiA specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.