ThermoBLOCK Mfumo wa Utoaji wa Mionzi ya Mshipa wa Varicose
A masafa ya redio jukwaa la ablation kwa wasio na uwezo mishipa ya juu juu, kutoa joto kufungwa kwa mishipa ya saphenous au perforating ili kupunguza varicose dalili.
The Thermal Coagulation RF Ablation Generator ni ya juu, feedback-driven system designed to deliver high-frequency radiofrequency (RF) energy to ThermoBLOCK™ catheters na ThermoBLOCK™ stylets—enabling inayolengwa thermal ablation for chronic venous insufficiency (CVI). Equipped with a wakati halisi monitoring mechanism, the generator precisely regulates intravascular heat parameters, ensuring salama na consistent power application while protecting surrounding tissues.
Real-Time Feedback Control
- Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
- Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
Precision RF Delivery
- Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing na sealing of incompetent veins.
- Uharibifu mdogo wa Dhamana: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
Kiolesura Inayofaa Mtumiaji
- Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
- Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
Versatile Integration
- ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
- Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
- Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
- Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
- Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing na sealing of incompetent veins.
- Uharibifu mdogo wa Dhamana: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
- Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
- Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
- ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
- Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
Vipimo vya Bidhaa
Vipimo | Maelezo / Thamani |
Jina la Bidhaa | ThermoBLOCK Varicose Vein RF Ablation System |
Matumizi yaliyokusudiwa | Endovenous radiofrequency ablation (RFA) of incompetent saphenous or perforator veins |
RF Catheter Design | 6–7F catheter with electrode segment near distal tip, temperature-controlled |
Nominal Power | ~10–30 W (depends on vein diameter and system setting) |
Urefu wa Catheter | ~60–120 cm (varies by code) |
Generator Compatibility | ThermoBLOCK RF Generator or universal 460 kHz system |
Temperature Monitoring | Integrated thermocouple in ablation segment |
Treatment Cycle | Typically ~20–40 seconds per segment, auto-regulated by temperature feedback |
Kuzaa | Tasa, Matumizi Moja |
Maisha ya Rafu | ~2–3 years at 15–25 °C |
Dalili za Kliniki | Great saphenous vein (GSV) reflux, small saphenous vein, perforator incompetence |
Contraindications | Unclear vein anatomy, severe peripheral arterial disease, known intolerance to device materials |
Matrix ya Kuagiza & Ukubwa
Ukubwa wa Catheter (F) | Urefu wa Katheta (cm) | Ablation Segment (cm) | Kanuni ya Bidhaa | Vidokezo |
6F | 60 | 7 | TBLK-6F-60-7 | Short catheter for small segments |
6F | 100 | 7 | TBLK-6F-100-7 | Standard ablation length, extended shaft |
7F | 100 | 10 | TBLK-7F-100-10 | Longer ablation segment for large GSV trunk |
7F | 120 | 10 | TBLK-7F-120-10 | For taller patients or more extensive reflux |
7F | 120 | 15 | TBLK-7F-120-15 | Extra ablation segment for major trunk veins |