Spider™ Peripheral Detachable Coil System (Detachable Pushable)
A detachable coil kit for embolization of peripheral aneurysms, AV fistulas, or abnormal vessels, providing stable coil packing with kudhibitiwa mechanical detachment.
The Spider™ Peripheral Detachable Coil System in its detachable pushable configuration is engineered by Invamed—a global medical device manufacturer—to address peripheral aneurysm occlusion, vascular malformations, or fistulae requiring controlled coil placement. By offering a pushable yet detachable delivery mechanism, Spider™ affords the precision of in-place detachment without the complexity of electrolytic release, optimizing procedural control and reducing risk of coil migration.
Detachable Pushable Delivery
Combines the ease of a pushable coil insertion with the detachment control typically associated with mechanical or electrolytic systems, enabling safe retrieval or repositioning before final deployment.
Platinum Coil
High radiopacity ensures real-time fluoroscopic monitoring, helping interventionalists confirm accurate coil positioning and packing density.
Soft & Conformable
The flexible coil design adapts to complex vessel anatomies or aneurysmal sacs, minimizing stress on fragile vessel walls.
Versatile Embolization
Ideal for small-to-moderate peripheral aneurysms, arteriovenous malformations (AVMs), or abnormal vascular communications, delivering precise occlusion.
Viashiria
Aneurysm repair (e.g., peripheral, visceral), AVM or fistula occlusion in peripheral territories, or general endovascular procedures requiring dense coil packing.
Contraindications
Vessels too small or tortuous to pass the delivery catheter, active infection at the access site, or scenarios where coil retrieval is not feasible.
Vipimo vya Bidhaa
Vipimo | Maelezo / Thamani |
Jina la Bidhaa | Spider Peripheral Detachable Coil System |
Matumizi yaliyokusudiwa | Endovascular embolization of peripheral aneurysms, AV fistulas, or abnormal vessels |
Coil Material | Platinum or platinum-tungsten alloy with detachable mechanism |
Detachment Method | Mechanical or electrolytic (verify final model) |
Coil Diameter Range | ~1.5–20 mm (varies by catalog code) |
Coil Length Range | ~1–40 cm (depending on coil diameter and framing vs. filling type) |
Delivery Microcatheter | Typically 2.3–2.7F inner diameter, 0.016–0.021” ID |
Mionzi ya mionzi | Platinum coil for fluoroscopic visualization |
Kuzaa | Tasa, Matumizi Moja |
Maisha ya Rafu | ~3–5 years at 15–25 °C |
Dalili za Kliniki | Peripheral aneurysm occlusion, AVF closure, selective vessel sacrifice |
Contraindications | Vessels too small or tortuous to accommodate microcatheter, known device material allergies |
Matrix ya Kuagiza & Ukubwa
Coil Diameter (mm) | Coil Length (cm) | Detachment Type | Kanuni ya Bidhaa | Vidokezo |
1.5 | 2 | Mechanical | SPD-P-1.5x2-M | Very small coil for micro-aneurysms |
1.5 | 4 | Electrolytic | SPD-P-1.5x4-E | Extended length, small diameter |
3.0 | 10 | Mechanical | SPD-P-3.0x10-M | Mid-range coil diameter, framing type |
3.0 | 15 | Electrolytic | SPD-P-3.0x15-E | Longer filling coil for larger sac |
5.0 | 15 | Mechanical | SPD-P-5.0x15-M | Medium coil for moderate aneurysms |
5.0 | 20 | Electrolytic | SPD-P-5.0x20-E | Extended coil length, filling type |
10.0 | 20 | Mechanical | SPD-P-10.0x20-M | Larger diameter coil for bigger aneurysms |
10.0 | 40 | Electrolytic | SPD-P-10.0x40-E | Maximum length coil for large-volume occlusion |
Bidhaa zinazohusiana
-
Mfumo wa Kuondoa Uongozi wa Hero LASER
Soma zaidiA msingi wa laser kuwezesha kifaa cha uchimbaji sahihi na salama kuondolewa kwa inaongoza kwa moyo (pacemaker au ICD) katika visa vya maambukizi, utendakazi wa risasi, au uboreshaji.
-
Filler Wakala wa Uimarishaji Msingi wa Cyanoacrylate
Soma zaidiA cyanoacrylate adhesive embolic kwa mishipa au AVM kufungiwa, kutoa haraka upolimishaji inapogusana na damu, kuhakikisha muhuri wa chombo thabiti na mabaki kidogo.
-
VeinOFF Wakala wa Matibabu ya Mshipa wa Varicose
Soma zaidiA maalumu sclerosant au wambiso formula inayolenga yasiyo ya joto kuondolewa kwa mishipa ya varicose, inayohitaji anesthesia ndogo na muda mfupi wa utaratibu.
-
MultiBEAM Embolization Plug
Soma zaidiA multisided plug device for mishipa au aneurysmal occlusion, achieving reliable embolization in peripheral or saccular expansions with minimal migration.