Chuma cha pua cha Atlas Coronary Stent
A chuma cha pua sadaka ya stent ya moyo imara uadilifu wa muundo na rahisi uwasilishaji kwa uingiliaji kati wa mara kwa mara wa ugonjwa wa moyo (PCI), kusawazisha ufanisi wa gharama na utendakazi unaotegemewa.
The ATLAS Drug Eluting Coronary Stent System SS is a stainless steel (SS) stent platform coated with a sirolimus formulation (1 µg/mm²), designed to prevent restenosis and support durable revascularization in patients with coronary artery disease. By delivering a targeted antiproliferative effect at the lesion site, it is indicated for both de novo coronary lesions and in-stent restenosis (ISR) management, thereby extending its clinical versatility in the percutaneous coronary intervention (PCI) setting.
Stainless Steel Construction
- High Strength-to-Weight Ratio: Enables thinner struts without sacrificing radial force, ensuring ease of deliverability and vessel conformability.
- Proven Biocompatibility: Stainless steel has a long history of safe use in coronary interventions, supporting stable endothelization.
Laser-Cut Stent Design
- Optimized Strut Geometry: Precisely formed lattice structure provides consistent drug distribution and minimal tissue trauma.
- Improved Crossability: The low-profile SS stent tracks smoothly through complex or calcified lesions, reducing the need for extensive lesion preparation.
Sirolimus Drug Coating (1 µg/mm²)
- Targeted Antiproliferation: Gradual drug release inhibits smooth muscle cell proliferation, a primary contributor to in-stent restenosis.
- Enhanced Endothelialization: Balanced drug elution fosters early endothelial coverage, mitigating late stent thrombosis risk.
Pt-Ir Radiopaque Markers
- Fluoroscopic Precision: Platinum-iridium markers at the stent’s extremities promote accurate stent positioning in the coronary vasculature.
- Reduced Geographic Miss: Clear visibility assists operators in precise stent deployment and lesion coverage.
High-Pressure Endurance
Nominal pressure of 10 atm and a rated burst pressure of 20 atm provide interventional cardiologists the latitude to optimize stent expansion and device apposition based on lesion morphology.
Maelezo ya Jumla ya Bidhaa
Vipimo | Maelezo / Thamani |
Jina la Bidhaa | Atlas Coronary Stent (Stainless Steel) |
Stent Type | Balloon-Expandable Coronary Stent |
Nyenzo | 316L Stainless Steel (Medical Grade) |
Strut Thickness | ~100 μm (typical) |
Kubuni | Open-Cell or Hybrid-Cell design (varies by specific model) |
Nominal Pressure (NP) | ~8–9 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Mfumo wa Utoaji | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Utangamano wa Mwongozo | 0.014” |
Viashiria | Coronary artery lesion scaffolding (may be used as BMS or platform for DES coating) |
Contraindications | Lesions unsuitable for balloon-expandable stent, severely calcified vessels, left main disease if unprotected, etc. |
Kuzaa | Asiyezaa (Ethilini Oksidi) |
Matumizi Moja | Ndiyo |
Maisha ya Rafu | 2–3 years (based on final packaging and coating, if any) |
Joto la Uendeshaji | Recommended 15–25 °C for storage |
Misimbo ya Kina ya Kuagiza na Bidhaa kwa Kutegemea Ukubwa
Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Kanuni ya Bidhaa |
2.00 | 8 | 8 | 14 | ATLS-SS-2.00x08 |
2.00 | 12 | 8 | 14 | ATLS-SS-2.00x12 |
2.00 | 15 | 8 | 14 | ATLS-SS-2.00x15 |
2.00 | 18 | 9 | 16 | ATLS-SS-2.00x18 |
2.00 | 24 | 9 | 16 | ATLS-SS-2.00x24 |
2.00 | 28 | 9 | 16 | ATLS-SS-2.00x28 |
2.00 | 32 | 9 | 16 | ATLS-SS-2.00x32 |
2.00 | 38 | 9 | 16 | ATLS-SS-2.00x38 |
2.25 | 8 | 8 | 14 | ATLS-SS-2.25x08 |
2.25 | 12 | 8 | 14 | ATLS-SS-2.25x12 |
2.25 | 15 | 8 | 14 | ATLS-SS-2.25x15 |
2.25 | 18 | 9 | 16 | ATLS-SS-2.25x18 |
2.25 | 24 | 9 | 16 | ATLS-SS-2.25x24 |
2.25 | 28 | 9 | 16 | ATLS-SS-2.25x28 |
2.25 | 32 | 9 | 16 | ATLS-SS-2.25x32 |
2.25 | 38 | 9 | 16 | ATLS-SS-2.25x38 |
2.50 | 8 | 8 | 14 | ATLS-SS-2.50x08 |
2.50 | 12 | 8 | 14 | ATLS-SS-2.50x12 |
2.50 | 15 | 8 | 14 | ATLS-SS-2.50x15 |
2.50 | 18 | 9 | 16 | ATLS-SS-2.50x18 |
2.50 | 24 | 9 | 16 | ATLS-SS-2.50x24 |
2.50 | 28 | 9 | 16 | ATLS-SS-2.50x28 |
2.50 | 32 | 9 | 16 | ATLS-SS-2.50x32 |
2.50 | 38 | 9 | 16 | ATLS-SS-2.50x38 |
2.75 | 8 | 8 | 14 | ATLS-SS-2.75x08 |
2.75 | 12 | 8 | 14 | ATLS-SS-2.75x12 |
2.75 | 15 | 8 | 14 | ATLS-SS-2.75x15 |
2.75 | 18 | 9 | 16 | ATLS-SS-2.75x18 |
2.75 | 24 | 9 | 16 | ATLS-SS-2.75x24 |
2.75 | 28 | 9 | 16 | ATLS-SS-2.75x28 |
2.75 | 32 | 9 | 16 | ATLS-SS-2.75x32 |
2.75 | 38 | 9 | 16 | ATLS-SS-2.75x38 |
3.00 | 8 | 8 | 14 | ATLS-SS-3.00x08 |
3.00 | 12 | 8 | 14 | ATLS-SS-3.00x12 |
3.00 | 15 | 8 | 14 | ATLS-SS-3.00x15 |
3.00 | 18 | 9 | 16 | ATLS-SS-3.00x18 |
3.00 | 24 | 9 | 16 | ATLS-SS-3.00x24 |
3.00 | 28 | 9 | 16 | ATLS-SS-3.00x28 |
3.00 | 32 | 9 | 16 | ATLS-SS-3.00x32 |
3.00 | 38 | 9 | 16 | ATLS-SS-3.00x38 |
3.50 | 8 | 8 | 14 | ATLS-SS-3.50x08 |
3.50 | 12 | 8 | 14 | ATLS-SS-3.50x12 |
3.50 | 15 | 8 | 14 | ATLS-SS-3.50x15 |
3.50 | 18 | 9 | 16 | ATLS-SS-3.50x18 |
3.50 | 24 | 9 | 16 | ATLS-SS-3.50x24 |
3.50 | 28 | 9 | 16 | ATLS-SS-3.50x28 |
3.50 | 32 | 9 | 16 | ATLS-SS-3.50x32 |
3.50 | 38 | 9 | 16 | ATLS-SS-3.50x38 |
4.00 | 8 | 8 | 14 | ATLS-SS-4.00x08 |
4.00 | 12 | 8 | 14 | ATLS-SS-4.00x12 |
4.00 | 15 | 8 | 14 | ATLS-SS-4.00x15 |
4.00 | 18 | 9 | 16 | ATLS-SS-4.00x18 |
4.00 | 24 | 9 | 16 | ATLS-SS-4.00x24 |
4.00 | 28 | 9 | 16 | ATLS-SS-4.00x28 |
4.00 | 32 | 9 | 16 | ATLS-SS-4.00x32 |
4.00 | 38 | 9 | 16 | ATLS-SS-4.00x38 |
Bidhaa zinazohusiana
-
Lotus Single Lumen & Double Lumen (RX) PTCA Microcatheter
Soma zaidiMicrocatheters iliyoundwa kwa ajili ya moyo au kivuko cha vidonda vya pembeni, kinachotoa usanidi wa lumen moja au mbili kwa kubadilishana guidewire, sindano ya kulinganisha, au ufikiaji wa kidonda uliochaguliwa.
-
Mfumo wa Kuondoa Uongozi wa Hero LASER
Soma zaidiA msingi wa laser kuwezesha kifaa cha uchimbaji sahihi na salama kuondolewa kwa inaongoza kwa moyo (pacemaker au ICD) katika visa vya maambukizi, utendakazi wa risasi, au uboreshaji.
-
Hero Mechanical Lead Removal System
Soma zaidiA mechanical alternative for lead extraction, employing specialized locking stylets or sheaths to dislodge fibrotic attachments, ensuring steady traction for safe removal.
-
Extender Drug Eluting PTA Balloon Catheter
Soma zaidiExtender Drug Eluting PTA Balloon Catheter; A drug-coated balloon for peripheral transluminal angioplasty (PTA), releasing antiproliferative agents to mitigate restenosis in femoral or popliteal arteries.