Mantis CURVE Over-the-Wire (OTW) Rotational Pharmacomechanical Thrombectomy System
En over-the-wire (OTW) device merging roterande disruption with pharmacologic lysis, effectively clearing large thrombi while protecting healthy vessel walls.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
PTFE invändigt foder
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Produktspecifikationer
Specifikation | Detalj / värde |
Produktens namn | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
Avsedd användning | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
Design av katetrar | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
Rotational Speed Range | ~40k–80k rpm (verify final) |
Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
Yttre diameter (F) | ~5–7F, depending on model |
Arbetslängd | ~80–120 cm (varies by product code) |
Kompatibilitet med guidewire | Typically 0.035” (OTW approach) |
Sterilitet | Steril, engångsbruk |
Hållbarhet | ~2-3 år vid 15-25 °C i försluten förpackning |
Kliniska indikationer | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
Kontraindikationer | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Beställning & storleksmatris
Yttre diameter (F) | Arbetslängd (cm) | Curve Tip Configuration | Produktkod | Anteckningar |
5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Relaterade produkter
-
Atlas Venös stent
Läs merEtt specialiserat implantatsystem tillverkat av biokompatibla metallegeringar, utformat för att behandla venösa obstruktioner genom att bibehålla kärlets öppenhet, förbättra blodflödet och lindra symtomen på kronisk venös insufficiens.
-
NOD Valvulotome
Läs merA titan eller legering system för sternalplatta som tillhandahåller styv fixering efter sternotomi i mittlinjen, vilket förbättrar sternal stabilitet och minska risken för infektion eller dehiscens efter hjärtkirurgi.
-
Viper™ Valved Infusion Catheters
Läs merDen Viper™ Valved Infusion Catheter är en single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with eller without a guidewire in place.
-
Extender PTCA-ballongkateter
Läs merA standard högtryck ballong för kranskärl utformad för lesion predilation eller fristående angioplastikvilket ger exakta uppblåsningsprofiler och minskade korsningsprofiler.