Atlas Venös stent
Ett specialiserat implantatsystem tillverkat av biokompatibla metallegeringar, utformat för att behandla venösa obstruktioner genom att bibehålla kärlets öppenhet, förbättra blodflödet och lindra symtomen på kronisk venös insufficiens.
Den Atlas™ Venous Stent, introduced by Inkräktad-a global tillverkare av medicintekniska produkter—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a självutvidgande nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting hållbar patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Kontraindikationer
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
Specifikation | Detalj / värde |
Produktens namn | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
Mekanism för utplacering | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
Radiell kraft | Moderate to high, designed to resist extrinsic compression |
Stentdiameterintervall | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
Radiopaka markörer | Proximal and distal markers for fluoroscopic visualization |
Sterilitet | Sterile, single use |
Hållbarhet | ~3–5 years if stored at 15–25 °C |
Kliniska indikationer | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | Produktkod | Anteckningar |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
Relaterade produkter
-
Viper™ Valved Infusion Catheters
Läs merDen Viper™ Valved Infusion Catheter är en single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with eller without a guidewire in place.
-
LaserBLOCK lasersystem för åderbråck
Läs merEn endovenös laserterapi inställd för åderbråck vener, utnytjande riktade laserenergi för att termiskt täta inkompetenta vener, vilket möjliggör snabb återgång till dagliga aktiviteter.
-
ICT Intern kompressionsterapi
Läs merICT Valvular Leak Sealer Reconstruction System
ICT is an Internal Compression Therapy for dysfunctioning vein valves. The procedure is also called percutaneous valvuloplasty.
-
AngioHAND Clot Removal Catheter
Läs merA hand-manipulated mechanical aspiration device enabling immediate clot extraction through a manual vacuum approach, simplifying acute thrombectomy procedures.