Stena Intrakraniell flödesmodulator med flera lager

A flerskikt flödesförstörande konstruktion för intrakraniella aneurysmeroch omdirigerar blodflödet bort från aneurysm-säcken samtidigt som perfusionen i viktiga grenar upprätthålls.

Den Stent Neurovascular Multilayer Flow Modulator är en multi-layer, self-expandable implant designed to redirect blood flow across intracranial aneurysms or pseudoaneurysms (saccular, fusiform, or dissection). Constructed from nitinol braided wires, this flow-guided device harnesses hemodynamic modulation to promote stable aneurysm occlusion while preserving key vessel branches.

Multi-Layer Braided Nitinol Wires
  • Self-Expanding Implant: Adapts seamlessly to the host vessel, delivering gentle but consistent radial support.
  • Optimized Flow Modulation: Braided mesh design disperses hemodynamic forces, encouraging gradual aneurysm thrombosis without aggressively blocking perforator flow.
  • Excellent Visibility: Enhanced radiopacity simplifies device deployment and positioning under fluoroscopic guidance.
  • Continuous Vessel Coverage: The robust structure ensures stable wall apposition, helping minimize device migration or incomplete vessel coverage.
  • Size-Specific Microcatheters: Designed for use with 3.6F or 3.9F microcatheter (outer) and 2.3F internal microcatheter, ensuring exakt navigation and stent delivery.
  • Pre-Loaded Configuration: The stent is supplied pre-loaded on its dedicated delivery system, streamlining procedural workflow and minimizing device manipulation.
  • Percutaneous Arterial Approach: Minimizes invasive exposure by allowing stent introduction through small-caliber femoral or radial arteries.
  • Adaptive Vessel Conformance: The device maintains uniform radial force along irregular or tortuous intracranial segments, preserving branch patency.
  • Self-Expanding Implant: Adapts seamlessly to the host vessel, delivering gentle but consistent radial support.
  • Optimized Flow Modulation: Braided mesh design disperses hemodynamic forces, encouraging gradual aneurysm thrombosis without aggressively blocking perforator flow.
  • Excellent Visibility: Enhanced radiopacity simplifies device deployment and positioning under fluoroscopic guidance.
  • Continuous Vessel Coverage: The robust structure ensures stable wall apposition, helping minimize device migration or incomplete vessel coverage.
  • Size-Specific Microcatheters: Designed for use with 3.6F or 3.9F microcatheter (outer) and 2.3F internal microcatheter, ensuring exakt navigation and stent delivery.
  • Pre-Loaded Configuration: The stent is supplied pre-loaded on its dedicated delivery system, streamlining procedural workflow and minimizing device manipulation.
  • Percutaneous Arterial Approach: Minimizes invasive exposure by allowing stent introduction through small-caliber femoral or radial arteries.
  • Adaptive Vessel Conformance: The device maintains uniform radial force along irregular or tortuous intracranial segments, preserving branch patency.

Produktspecifikationer

Specifikation Detalj / värde
Produktens namn Stena Intrakraniell flödesmodulator med flera lager
Avsedd användning Endovascular flow diversion for intracranial aneurysms (saccular, fusiform) or complex neurovascular lesions
Design Multi-layer braided nitinol mesh stent, self-expanding, designed to modulate blood flow while preserving side branches
Material Medical-grade Nitinol (Nickel-Titanium)
Mekanism för utplacering Sheath-based retraction or microcatheter system release
Delivery Catheter Compatibility Typically 0.027” or 0.021” ID microcatheter (depending on stent diameter)
Radiopaka markörer Proximal and distal marker bands for fluoroscopic positioning
MR-kompatibilitet MR Conditional (verify labeling)
Sterilitet Steril, engångsbruk
Hållbarhet ~3–5 years, stored at 15–25 °C in sealed packaging
Kliniska indikationer Intracranial aneurysms (small or large/giant), dissecting or fusiform aneurysms, flow diversion in distal vessels
Kontraindikationer Extremely tortuous intracranial vessels beyond feasible access, known nickel allergy, insufficient landing zone

Beställning & storleksmatris

Stent Diameter (mm) Stent Length (mm) Microcatheter ID (inch) Produktkod Anteckningar
2.5 12 0.021" STN-IC-2.5x12-021 Smaller diameter, short aneurysm coverage
2.5 18 0.021" STN-IC-2.5x18-021 Extended length for multiple side branches
3.0 18 0.027" STN-IC-3.0x18-027 Common diameter for medium intracranial vessels
3.0 25 0.027" STN-IC-3.0x25-027 Longer stent for extended aneurysm neck
3.5 20 0.027" STN-IC-3.5x20-027 Slightly larger diameter for wide-neck aneurysms
3.5 30 0.027" STN-IC-3.5x30-027 Extended coverage in more proximal segments
4.0 20 0.027" STN-IC-4.0x20-027 Larger diameter for cavernous ICA aneurysms
4.0 30 0.027" STN-IC-4.0x30-027 Extended length for giant aneurysm coverage
4.5 25 0.027" STN-IC-4.5x25-027 XL diameter for large internal carotid segments
4.5 35 0.027" STN-IC-4.5x35-027 Maximum coverage for fusiform or dissecting lesions