Mantis CURVE Over-the-Wire (OTW) Rotational Pharmacomechanical Thrombectomy System
En over-the-wire (OTW) device merging roterande disruption with pharmacologic lysis, effectively clearing large thrombi while protecting healthy vessel walls.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
PTFE invändigt foder
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Produktspecifikationer
Specifikation | Detalj / värde |
Produktens namn | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
Avsedd användning | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
Design av katetrar | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
Rotational Speed Range | ~40k–80k rpm (verify final) |
Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
Yttre diameter (F) | ~5–7F, depending on model |
Arbetslängd | ~80–120 cm (varies by product code) |
Kompatibilitet med guidewire | Typically 0.035” (OTW approach) |
Sterilitet | Steril, engångsbruk |
Hållbarhet | ~2-3 år vid 15-25 °C i försluten förpackning |
Kliniska indikationer | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
Kontraindikationer | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Beställning & storleksmatris
Yttre diameter (F) | Arbetslängd (cm) | Curve Tip Configuration | Produktkod | Anteckningar |
5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Relaterade produkter
-
MultiBEAM Filter för Vena Cava Inferior (IVC)
Läs merEn konvertibel eller återvinningsbar IVC-filter förhindrar Lungemboli genom att fånga upp blodproppar som färdas genom vena cava inferior, vilket garanterar säkerheten för högriskpatienter.
-
LaserBLOCK lasersystem för åderbråck
Läs merEn endovenös laserterapi inställd för åderbråck vener, utnytjande riktade laserenergi för att termiskt täta inkompetenta vener, vilket möjliggör snabb återgång till dagliga aktiviteter.
-
Mantis PRO Rotational Thrombectomy & Ultra Aspiration
Läs merA roterande system featuring for mekanisk clot fragmentation plus strong aspiration capabilities in deep venous or arterial occlusions.
-
VascuVac Tekniker för ai-assisterad vakuumtrombektomi
Läs merEtt innovativt system som använder AI-assisterad teknik för effektiv vakuumtrombektomi, utformat för att snabbt avlägsna blodproppar från blodkärl, återställa blodflödet, och minimera procedurmässiga risker vid vaskulära ingrepp.