ThermoBLOCK Systém rádiofrekvenčnej ablácie kŕčových žíl

A radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.

Stránka Thermal Coagulation RF Ablation Generator je pokročilé, feedback-driven system designed to deliver high-frequency radiofrequency (RF) energy to ThermoBLOCK™ catheters a ThermoBLOCK™ stylets—enabling cielené thermal ablation for chronic venous insufficiency (CVI). Equipped with a v reálnom čase monitoring mechanism, the generator precisely regulates intravascular heat parameters, ensuring bezpečné a consistent power application while protecting surrounding tissues.

Real-Time Feedback Control
  • Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
  • Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
  • Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing a sealing of incompetent veins.
  • Minimálne vedľajšie škody: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
  • Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
  • Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
  • ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
  • Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
  • Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
  • Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
  • Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing a sealing of incompetent veins.
  • Minimálne vedľajšie škody: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
  • Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
  • Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
  • ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
  • Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.

Špecifikácie produktu

Špecifikácia Detail / Hodnota
Názov produktu ThermoBLOCK Varicose Vein RF Ablation System
Zamýšľané použitie Endovenous radiofrequency ablation (RFA) of incompetent saphenous or perforator veins
RF Catheter Design 6–7F catheter with electrode segment near distal tip, temperature-controlled
Nominal Power ~10–30 W (depends on vein diameter and system setting)
Dĺžka katétra ~60–120 cm (varies by code)
Generator Compatibility ThermoBLOCK RF Generator or universal 460 kHz system
Temperature Monitoring Integrated thermocouple in ablation segment
Treatment Cycle Typically ~20–40 seconds per segment, auto-regulated by temperature feedback
Sterilita Sterilné, na jedno použitie
Doba skladovania ~2–3 years at 15–25 °C
Klinické indikácie Great saphenous vein (GSV) reflux, small saphenous vein, perforator incompetence
Kontraindikácie Unclear vein anatomy, severe peripheral arterial disease, known intolerance to device materials

Objednávanie a matica veľkostí

Veľkosť katétra (F) Dĺžka katétra (cm) Ablation Segment (cm) Kód produktu Poznámky
6F 60 7 TBLK-6F-60-7 Short catheter for small segments
6F 100 7 TBLK-6F-100-7 Standard ablation length, extended shaft
7F 100 10 TBLK-7F-100-10 Longer ablation segment for large GSV trunk
7F 120 10 TBLK-7F-120-10 For taller patients or more extensive reflux
7F 120 15 TBLK-7F-120-15 Extra ablation segment for major trunk veins