Mantis Trombectomia rotacional com ponta de lâmina e ultra-aspiração
A rotacional com um sistema de ponta da folha conceção para mecânico fragmentação do coágulo mais forte capacidades de aspiração em oclusões venosas ou arteriais profundas.
O Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.
Leaf Tip Design
- The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
- Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
Nitinol Shaft with PA/PEBAX
- High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
- Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
Radiopaque Shaft Markings
- Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
- Facilitates accurate positioning and ensures confident navigation through complex vascular pathways.
Flexible Catheter Profiles
- Available in 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
- Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.
Multiple Catheter Lengths
90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.
Especificações do produto
Especificação | Detalhe / Valor |
Nome do produto | Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration |
Utilização prevista | Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems |
Conceção do cateter | Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal |
Material | Stainless steel or nitinol drive shaft, flexible polymer outer sheath |
Rotational Speed Range | ~40k–80k rpm (check final specs) |
Aspiration Mechanism | Over-the-wire suction or integrated vacuum line |
Catheter Outer Diameter | ~5–7F, depending on model and tip size |
Comprimento de trabalho | ~80–120 cm (varies by product code) |
Radiopacidade | Distal marker near leaf tip for precise positioning under fluoroscopy |
Esterilidade | Estéril, de utilização única |
Prazo de validade | ~2–3 years at 15–25 °C |
Indicações clínicas | Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT) |
Contra-indicações | Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials |
Matriz de tamanhos e encomendas
Diâmetro exterior (F) | Comprimento de trabalho (cm) | Leaf Tip Diameter (mm) | Código do produto | Notas |
5F | 80 | 5 | MNT-LF-5F-80-5 | Smaller tip for distal or smaller vessels |
5F | 100 | 5 | MNT-LF-5F-100-5 | Longer shaft, same leaf diameter |
6F | 80 | 6 | MNT-LF-6F-80-6 | Common size for peripheral artery usage |
6F | 120 | 6 | MNT-LF-6F-120-6 | Extended length for deeper or proximal segments |
7F | 100 | 7 | MNT-LF-7F-100-7 | Larger leaf tip for heavier thrombus loads |
7F | 120 | 7 | MNT-LF-7F-120-7 | Max length and larger tip for extensive clot burden |
Produtos Relacionados
-
Extender Cateter de balão PTCA com eluição de fármacos Paclitaxel
Ler maisA revestido com paclitaxel cateter balão coronário destinado a reduzir a reestenose durante a angioplastia coronária transluminal percutânea (PTCA), assegurando a administração eficaz do fármaco na parede do vaso.
-
Sistema de ablação por radiofrequência para varizes ThermoBLOCK
Ler maisA radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.
-
Extender Cateter de balão PTCA
Ler maisA padrão alta pressão balão coronário Concebido para pré-dilatação da lesão ou autónomo angioplastiaque oferece perfis de insuflação precisos e perfis de cruzamento reduzidos.
-
Mantis PRO Trombectomia rotacional e ultra-aspiração
Ler maisA rotacional sistema com caraterísticas para mecânico fragmentação do coágulo mais forte capacidades de aspiração em oclusões venosas ou arteriais profundas.