Peta Descompressão mecânica percutânea do disco
Concebido com materiais de engenharia de precisão, este dispositivo minimamente invasivo permite a descompressão eficaz de hérnias discais, aliviando a pressão sobre os nervos espinais e aliviando a dor, ao mesmo tempo que promove uma recuperação mais rápida.
Peta Mechanical Percutaneous Disk Decompression by Invamed is an innovative, single-use system that enables mechanical nucleus removal via a percutaneous approach. Designed to relieve discogenic pain and address contained disc herniations, this mechanical device uses cutting and suction or nibbling mechanisms (depending on the specific SKU) to precisely extract nucleus pulposus tissue. By preserving annular integrity, it promotes faster patient recovery and lowers the risk of complications commonly associated with more invasive spine surgery.
Minimally Invasive Percutaneous Access
- Deployed through a small-diameter cannula or introducer, requiring only a minimal incision.
- Reduces postoperative discomfort, scarring, and risk to adjacent anatomical structures compared to open discectomies.
Mechanical Debulking Mechanism
- Utilizes a cutting, nibbling, or auger-like tip to remove nucleus material effectively from within the disc.
- Real-time tactile feedback helps the operator gauge disc removal progress, preventing over-resection.
Precise Disc Clearing & Pain Relief
- Controlled resection of excess nucleus diminishes intradiscal pressure, offering symptomatic relief for radicular pain or mild degenerative disc disease.
- Preserves annular stability, reducing re-herniation risk relative to more aggressive resection.
Single-Use, Sterile System
- Disposable device ensures consistent performance and removes the need for elaborate reprocessing or repeated sterilization cycles.
- Each kit is individually packaged sterile, facilitating safe, efficient OR workflow and reducing infection risk.
Indicações versáteis
- Primarily intended for lumbar disc decompressions (L4-L5, L5-S1), though suitable for certain cervical or thoracic segments where contained herniations exist.
- Ideal for patients with mild-to-moderate disc prolapse, discogenic back pain, or radicular symptoms not fully resolved with conservative treatments.
Peta Mechanical Percutaneous Disk Decompression - 1
Especificação | Detalhe / Valor |
Nome do produto | Peta Mechanical Percutaneous Disk Decompression (Invamed) |
Mecanismo | Mechanical cutting, nibbling, or auger-based removal of disc nucleus material via percutaneous approach |
Device Profile | Low-profile introducer or cannula system (outer diameter often ~2–3 mm); mechanical tip integrated for disc excision |
Esterilidade | Single-use, sterile-packed; typically EtO or gamma sterilized |
Comprimento de trabalho | ~100–150 mm (depending on spinal level targeted and approach) |
Orientação para imagiologia | Recommended under fluoroscopy or CT to confirm device positioning and disc material removal progress |
Intended Spine Levels | Typically L3–S1 for lumbar; consult product labeling for cervical/thoracic adaptation |
Indicações clínicas | Contained disc herniations, discogenic low back pain, mild degenerative disc disease requiring mechanical decompression |
Peta Mechanical Percutaneous Disk Decompression - 2
Introducer Diameter (mm) | Working Length (mm) | Approach | Código do produto | Notas |
2.0 | 100 | Posterolateral (Lumbar) | PETA-DKD-2.0-100-PL-Ti | Slender device for low-profile lumbar access; suitable for small disc spaces |
2.5 | 100–120 | Posterolateral (Lumbar) | PETA-DKD-2.5-XXX-PL-Ti | Balanced diameter enabling moderate nucleus extraction while maintaining minimal trauma |
3.0 | 120–150 | Oblique (Thoracolumbar) | PETA-DKD-3.0-XXX-OB-Ti | Larger diameter for more robust disc material removal; indicated for bigger discs |
3.0 | 120 | Anterolateral (Cervical) | PETA-DKD-3.0-120-AL-Ti | Adapted approach for cervical discs; typically used with specialized retractor systems |
Produtos Relacionados
-
VitaFLEX Hyaluronic Acid Intradermal
Ler maisComposed of high-purity hyaluronic acid, this biocompatible dermal filler improves skin hydration, elasticity, and volume, effectively minimizing fine lines and wrinkles for a more youthful appearance.
-
Extender Cateter de balão PTCA com eluição de fármacos Paclitaxel
Ler maisA revestido com paclitaxel cateter balão coronário destinado a reduzir a reestenose durante a angioplastia coronária transluminal percutânea (PTCA), assegurando a administração eficaz do fármaco na parede do vaso.
-
Stella Cranial Platinum Plate
Ler maisA platinum cranial fixation system for neurosurgical craniotomies, providing superior biocompatibility and fiável stability in skull reconstructions or tumor resections.
-
Clever Malha parcialmente absorvível
Ler maisUma malha cirúrgica leve combinando durabilidade e materiais absorvíveis, concebido para proporcionar um apoio temporário durante a cicatrização dos tecidos reduzindo simultaneamente a longo prazo presença de corpos estranhos em procedimentos como como a reparação de uma hérnia.