NeoAblate Sonda de ablação de tumores para tecidos moles e fígado
Um dispositivo de engenharia de precisão concebido para a ablação minimamente invasiva de tumores, fornecendo energia controlada para tratar eficazmente os tumores dos tecidos moles e do fígado, minimizando os danos nos tecidos saudáveis circundantes.
NeoAblate é um avançado thermal ablation system engineered for predictable, repeatable destruction of soft tissue e liver tumors. By combining multi-point temperature feedback, a scalable active heating elemente minimal incision demands, NeoAblate ensures exato, em tempo real monitoring of ablation zones while prioritizing patient comfort e operator workflow efficiency. With a single 18 gauge probe capable of adjustable lengths from 1–2.5 cm, NeoAblate simplifies tumor targeting in both CT e MRI contexts—supporting effective, minimamente invasivo procedures.
Caraterísticas principais
Predictable, Repeatable Ablations
- Dynamic Thermal Feedback: Integrates multi-point temperature monitoring (via 1 thermocouple) for em tempo real updates, enabling clinicians to fine-tune energy delivery.
- Consistent Tissue Coagulation: Maintains a stable, uniform thermal field, helping to achieve thorough ablation margins and reduce the risk of recurrence.
Single 18 Gauge Cannula Probe
- Scalable Active Length (1–2.5 cm): The ablation zone can be adjusted to match tumor size or shape, minimizing damage to adjacent healthy tissue.
- Slim Handle Design: Supports easy navigation and manipulation under ultrasound, CT, ou MRI guidance, especially beneficial for complex or deep-seated lesions.
Minimal Incision, No Soft Tissue Introducer Required
- Beveled Surgical Tip: Aids penetration of hard tumors with minimal trauma, limiting bleeding or post-procedure discomfort.
- Insertable Length Options: Available in 15 cm, 20 cm, ou 25 cm to accommodate varying patient body habitus and tumor locations.
Multi-Modal Imaging Compatibility
- Fits Both CT and MRI Gantries: A low-profile design ensures safe, unhindered scanning, letting operators confirm probe placement in real time.
- Precise Localization: Facilitates accurate, image-guided ablation for improved oncological outcomes.
- Dynamic Thermal Feedback: Integrates multi-point temperature monitoring (via 1 thermocouple) for em tempo real updates, enabling clinicians to fine-tune energy delivery.
- Consistent Tissue Coagulation: Maintains a stable, uniform thermal field, helping to achieve thorough ablation margins and reduce the risk of recurrence.
- Scalable Active Length (1–2.5 cm): The ablation zone can be adjusted to match tumor size or shape, minimizing damage to adjacent healthy tissue.
- Slim Handle Design: Supports easy navigation and manipulation under ultrasound, CT, ou MRI guidance, especially beneficial for complex or deep-seated lesions.
- Beveled Surgical Tip: Aids penetration of hard tumors with minimal trauma, limiting bleeding or post-procedure discomfort.
- Insertable Length Options: Available in 15 cm, 20 cm, ou 25 cm to accommodate varying patient body habitus and tumor locations.
- Fits Both CT and MRI Gantries: A low-profile design ensures safe, unhindered scanning, letting operators confirm probe placement in real time.
- Precise Localization: Facilitates accurate, image-guided ablation for improved oncological outcomes.
Vantagens e aplicações clínicas
Soft Tissue & Hepatic Tumors
- Ideal for Primary & Metastatic Lesions: Ablation is effective for liver tumors or other soft tissue malignancies in subcutaneous or intramuscular sites.
- Tissue Preservation: Focused heat confines the ablation zone around the tumor, sparing healthy parenchyma.
Less Surgical Trauma & Faster Recovery
- Minimal Access: A single 18 G insertion path can significantly reduce hospital stays, postoperative pain, or complications.
- Outpatient Potential: Some smaller lesions might be managed with sedation and local anesthesia, freeing up OR time and resources.
Efficient & Safe Procedure Flow
- Power Settings up to 40 W: Default target temperature ranges (80–110 °C) allow consistent, thorough ablation coverage.
- Warning & Monitoring Systems: Audible and light signals alert the operator to high/low temperature or extended ablation times, ensuring immediate corrective action if needed.
Enhanced Operator Confidence
- Real-Time Temperature Feedback: Minimizes overtreatment or incomplete ablation, standardizing the ablation zone.
- Ergonomic Stability: Slim handle and multiple insertable lengths ensure stable needle control even in challenging anatomies.
- Ideal for Primary & Metastatic Lesions: Ablation is effective for liver tumors or other soft tissue malignancies in subcutaneous or intramuscular sites.
- Tissue Preservation: Focused heat confines the ablation zone around the tumor, sparing healthy parenchyma.
- Minimal Access: A single 18 G insertion path can significantly reduce hospital stays, postoperative pain, or complications.
- Outpatient Potential: Some smaller lesions might be managed with sedation and local anesthesia, freeing up OR time and resources.
- Power Settings up to 40 W: Default target temperature ranges (80–110 °C) allow consistent, thorough ablation coverage.
- Warning & Monitoring Systems: Audible and light signals alert the operator to high/low temperature or extended ablation times, ensuring immediate corrective action if needed.
- Real-Time Temperature Feedback: Minimizes overtreatment or incomplete ablation, standardizing the ablation zone.
- Ergonomic Stability: Slim handle and multiple insertable lengths ensure stable needle control even in challenging anatomies.