GlideAccess Bainha de acesso ureteral
Concebida para uma navegação suave e eficiente, esta bainha de acesso ureteral proporciona um melhor acesso ao trato urinário, reduzindo o trauma e facilitando a passagem de instrumentos durante os procedimentos urológicos.
GlideAccess is a versatile, hydrophilic-coated ureteral access sheath engineered for atraumatic entry into the upper urinary tract—simplifying endoscopic procedures such as ureteroscopy and stone management. Featuring a unique tip-expanding system, the sheath transitions gently from its dilator to the external surface, minimizing patient discomfort and reducing mucosal trauma. With stainless-steel coil reinforcement, radiopaque markers, and a dilator lock mechanism, GlideAccess offers secure, anti-kink performance across a variety of lengths and diameters.
Atraumatic Tip Transition
- Unique Tip-Expanding System: Ensures a smooth, gradual opening that decreases friction at the ureteral orifice, reducing tissue irritation or injury.
- Protective Design: Minimizes patient discomfort during insertion or repositioning.
Dilator Lock Mechanism
- Secure Sheath-Dilator Connection: Prevents accidental separation, facilitating consistent advancement and controlled placement.
- Visual Control of Fixation: Confirms at-a-glance that the dilator is correctly engaged with the sheath.
High-End Construction
- PTFE Inner Layer: Ensures a low-friction lumen for smooth device passage (e.g., scopes, retrieval baskets), avoiding potential hang-ups or drag.
- Stainless-Steel Coil Reinforcement: Maintains sheath patency under bending forces, imparting robust anti-kink characteristics—critical in tortuous ureteral anatomy.
Marcadores radiopacos
- Sheath & Dilator Tip Visibility: Allows precise fluoroscopic or endoscopic confirmation of device position, key in complex anatomy.
- Efficient Localization: Helps operators define the exact transition point of the tip for atraumatic positioning.
Hydrophilic External Coating
- Enhanced Navigability: Reduces friction along ureteral walls, simplifying sheath advancement and retrieval.
- Lower Tissue Trauma: Minimizes ureteral irritation, diminishing bleeding or edema risks.
Tube Size & Profile Options
- Multiple Lengths: 35 or 45 cm suits various patient anatomies or scope placements.
- Inner & Outer Diameters (CH/FR): Wide range—10/12, 12/14, 14/16—covering typical ureteral requirements for stone extraction or endoscopic interventions.
Vantagens e aplicações clínicas
Facilitating Ureteroscopy
- Repetitive Instrument Exchange: Ensures comfortable and efficient scope passes, limiting repeated trauma to the ureteral orifice and walls.
- Stone Retrieval & Laser Lithotripsy: Streamlines manipulations of baskets, laser fibers, or retrieval devices, enhancing operative speed.
Reduced Procedure Times
- Reliable Anti-Kink Design: Maintains consistent patency for irrigation outflow and instrument movement, potentially lowering overall operative durations.
- Atraumatic Transition: Minimizes scope deflections or repeated sheath reintroductions, boosting procedural efficiency.
Heightened Patient Comfort & Safety
- Lower Mucosal Injury: The gentle tip transition mitigates excessive stress or friction within the ureter.
- Secure Placement: Locking mechanism keeps the dilator-sheath assembly stable, alleviating sudden disconnections or misplacement.
Versatile in Complex Ureteral Anatomy
- Hydrophilic Coating: Beneficial in managing acute angles, strictures, or narrower ureteral segments.
- Stainless-Steel Coil: Reinforces radial strength and consistent luminal diameter for large or rigid endourological instruments.
Technical Specifications
Parameter | Especificação |
Sheath Length (cm) | 35, 45 |
Inner Diameter (CH/FR) | 10, 12, 14 (consult labeling for exact match) |
Outer Diameter (CH/FR) | 12, 14, 16 (corresponding to the inner diameter) |
Tip Transition | Unique, atraumatic, tip-expanding design |
Coating & Materials | Hydrophilic exterior, PTFE inner layer, stainless-steel coil reinforcement, durable polymer/flexible plastic sheath |
Dilator Lock System | Secure fix for stable sheath-dilator alignment |
Radiopacidade | Radiopaque markers at tip for visible under fluoroscopy |
Anti-Kink | Stainless-steel coil design ensures minimal kink risk |
Compatibilidade | Standard endoscopes, flexible ureteroscopes, stone retrieval devices, laser fibers |
Indicações | Retrograde ureteral access, repeated instrumentation, stone extraction, stent placements |
Produtos Relacionados
-
UroLase: Ablação trans-uretral por laser para tumores da bexiga
Ler maisAblação trans-uretral a laser para tumores da bexiga: Um sistema laser de vanguarda concebido para a ablação precisa de tumores da bexiga através da uretra, oferecendo uma invasão mínima, hemorragia reduzida e maior precisão para uma remoção eficaz do tumor.
-
Fios-guia UroGuide
Ler maisFios-guia de engenharia de precisão concebidos para proporcionar um controlo e flexibilidade excepcionais durante os procedimentos urológicos, garantindo uma navegação suave e um melhor acesso ao trato urinário.
-
Bionovus Cateter de nefrostomia percutânea para nefrectomia (Pigtail)
Ler maisUm cateter pigtail concebido com precisão e adaptado para nefrostomia percutânea, garantindo uma colocação segura, uma drenagem eficiente e um menor desconforto para o doente durante a nefrectomia e procedimentos relacionados.
-
Fios-guia PTCA InWIRE
Ler maisA range of high-performance coronary guidewires offering duradouro nitinol or stainless cores, hydrophilic coatings, and multiple tip shapes for crossing calcificado ou complexo coronary lesions.