Sistema de trombectomia farmacomecânica rotacional Mantis CURVE Over-the-Wire (OTW)
Um por cabo (OTW) fusão de dispositivos rotacional perturbação com farmacológico lise, eliminando eficazmente os trombos de grandes dimensões enquanto protege as paredes saudáveis dos vasos.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
Revestimento interior em PTFE
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Especificações do produto
Especificação | Detalhe / Valor |
Nome do produto | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
Utilização prevista | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
Conceção do cateter | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
Rotational Speed Range | ~40k–80k rpm (verify final) |
Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
Diâmetro exterior (F) | ~5–7F, depending on model |
Comprimento de trabalho | ~80–120 cm (varies by product code) |
Compatibilidade de fios-guia | Typically 0.035” (OTW approach) |
Esterilidade | Estéril, de utilização única |
Prazo de validade | ~2-3 anos a 15-25 °C em embalagem selada |
Indicações clínicas | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
Contra-indicações | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Matriz de tamanhos e encomendas
Diâmetro exterior (F) | Comprimento de trabalho (cm) | Curve Tip Configuration | Código do produto | Notas |
5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Produtos Relacionados
-
ICT Terapia de compressão interna
Ler maisICT Valvular Leak Sealer Reconstruction System
ICT is an Internal Compression Therapy for dysfunctioning vein valves. The procedure is also called percutaneous valvuloplasty.
-
Fios-guia periféricos InWIRE
Ler maisMúltiplos periférico configurações de fios (hidrofílicos, rígidos, com comprimento de troca) que facilitam seguro cruzamento de lesões complexas ou calcificadas e garantia de um suporte estável do dispositivo.
-
Cateteres de infusão valvulados Viper™
Ler maisO Cateter de Infusão Valvulado Viper™ é um monolúmen, ponta valvulada sistema de entrega que oferece a flexibilidade de infundir agentes anti-trombos, contraste radiopaco ou outras soluções farmacológicas especificadas pelo médico com ou sem um fio-guia no local.
-
VascuVac Tecnologias de trombectomia por vácuo assistida por Ai
Ler maisUm sistema inovador que utiliza tecnologia assistida por IA para uma trombectomia por vácuo eficiente, concebido para remover rapidamente os trombos dos vasos sanguíneos, restabelecer a circulação sanguínea, e minimizar os riscos processuais em intervenções vasculares.