Laço endovascular Keeper
A multi-loop dispositivo de recolha de laços para corpo estranho ou embolo captura, assegurando seguro empenhamento e retirada dos lúmens vasculares.
Keeper Endovascular Snare by INVAMED is a single-use, sterile device engineered to capture and retrieve intravascular foreign objects, from dislodged stents or guidewire fragments to thrombosis and other undesirable materials in the vascular system. With an innovative loop design and low-profile catheter introduction, the Keeper Snare provides precise control, maximum radial force, and minimized trauma—streamlining procedures in both arterial and venous settings.
Flexible Snare Loop Geometry
- Constructed from high-tensile nitinol or stainless-steel wires in various loop diameters for optimal capture potential.
- Retains shape memory and radial strength even after multiple manipulation cycles, supporting consistent retrieval.
Ergonomic Catheter Delivery
- Low-profile catheter sheath simplifies femoral, radial, or brachial access.
- Catheter tip and snare loop are radiopaque, facilitating fluoroscopic or angiographic visualization and precise target approach.
Enhanced Capture and Control
- The snare loop compresses or expands under operator control, securely gripping foreign bodies or occlusive elements without risk of fragmenting them further.
- A dedicated handle or torque device (depending on model) provides precision in loop rotation and retraction.
Minimally Invasive Retrieval
- Reduces or eliminates the need for open surgical extraction, shortening patient recovery times and lowering complication risks.
- Effective for broken guidewires, catheter fragments, or other intraluminal materials that must be removed promptly to avoid embolization or vascular injury.
Broad Range of Indications
- Suitable for arterial or venous retrieval in peripheral vessels, central vasculature, or even select cardiac chambers if indicated.
- Helpful in addressing intravascular coil misplacements, filter retrievals, or spontaneous foreign body presence.
Especificações do produto
Especificação | Detalhe / Valor |
Nome do produto | Laço endovascular Keeper |
Utilização prevista | Retrieval of foreign bodies, dislodged stents, or thrombus fragments from vascular lumens |
Snare Material | Nitinol or Stainless Steel loop with radiopaque marker |
Loop Diameter Range | ~2–35 mm (depending on vessel size) |
Shaft Length | 80–120 cm (various) |
Compatibilidade de fios-guia | 0.018” or 0.035” (check model) |
Sheath Compatibility | 4–6F typical |
Esterilidade | Estéril, de utilização única |
Prazo de validade | ~3 years, 15–25 °C storage |
Matriz de tamanhos e encomendas
Loop Diameter (mm) | Shaft Length (cm) | Guidewire Size | Código do produto |
5 | 80 | 0.018" | KEE-5-80-018 |
10 | 80 | 0.018" | KEE-10-80-018 |
15 | 100 | 0.035” | KEE-15-100-035 |
20 | 100 | 0.035” | KEE-20-100-035 |
25 | 120 | 0.035” | KEE-25-120-035 |
35 | 120 | 0.035” | KEE-35-120-035 |
Produtos Relacionados
-
Sistema de stent coronário com eluição de fármacos ATLAS Crómio-cobalto
Ler maisA cobalto-crómio colocação de stent coronário resistência radial duradoura e excelente rastreabilidadeadequado para complexo ou calcificado lesões coronárias, assegurando simultaneamente um recuo mínimo.
-
Sistema mecânico de remoção de chumbo Hero
Ler maisA mecânico alternativa para extração de chumboutilizando estiletes ou bainhas de bloqueio especializadas para deslocar anexos fibróticos, assegurando estável tração para uma remoção segura.
-
Atlas Sistema de stent coronário em aço inoxidável
Ler maisA aço inoxidável oferta de stents coronários robusto integridade estrutural e fácil para intervenções coronárias percutâneas (ICP) de rotina, equilibrando a relação custo-eficácia com um desempenho fiável.
-
Atlas Endoprótese aórtica
Ler maisA coberto sistema de stent para endovascular reparação do aneurisma da aorta, evitando a pressurização do saco aneurismático e permitindo a permeabilidade segura do lúmen.