Cateter de suporte DolphinPro
A apoio à travessia cateter para complexo lesões periféricas ou coronárias, com uma veio reforçado e hidrofílico revestimento para facilitar a entrega do dispositivo.
DolphinPro Support Catheter by Invamed is specifically engineered to cross complex lesions in difficult anatomies during femoro-popliteal and below-the-knee procedures. Its robust stainless steel double-braiding ensures a kink-resistant design with exceptional torque control, allowing seamless navigation through tortuous vessels. By featuring a small crossing profile, DolphinPro delivers unparalleled support and pushability, facilitating successful lesion crossing and enabling telescope technique in endovascular interventions.
Stainless Steel Double-Braiding
A unique multi-layer shaft construction combines kink resistance with dynamic torque control, providing stable maneuverability even in challenging anatomical routes.
Optimal Push Transition
Seamlessly transfers applied force from the proximal shaft to the distal tip, aiding clinicians in tackling complex, heavily calcified or eccentric lesions without compromising on control.
Small Crossing Profile
Minimizes friction and vessel trauma, improving guidewire-to-catheter transitions. This design optimizes trackability within narrow below-the-knee vessels or severe occlusive segments.
Telescope Technique
DolphinPro’s flexible distal segment and supportive proximal section facilitate telescope approach, helping operators reach distal lesions and perform targeted interventions under precise control.
Broad Clinical Utility
Ideal for femoro-popliteal occlusions, tibioperoneal blockages, or challenging SFA lesions, where high pushability and low-profile crossing are crucial to procedural success.
Contra-indicações
- Extreme vessel tortuosity or diameter below specification
- Active infection or severe vessel dissection precluding wire-based recanalization
- Patient conditions contraindicating endovascular procedures
Technical Specifications
| Especificação | Detalhe / Valor |
| Nome do produto | Cateter de suporte DolphinPro |
| Utilização prevista | Lesion crossing and support in femoro-popliteal & BTK interventions |
| Shaft Construction | Stainless Steel Double-Braiding with advanced polymer coatings |
| Proximal Diameter | Low-profile crossing design; verify available French sizes based on region |
| Distal Tip Profile | Tapered, reinforced tip for improved guidewire entry and lesion crossing |
| Length Options | Common lengths ranging from 65 cm to 150 cm; additional lengths upon request |
| Compatibilidade de fios-guia | Typically 0.014” or 0.018” (verify exact compatibility) |
| Radiopacidade | Radiopaque distal tip and markers for precise visualization |
| Esterilidade | Provided sterile (single use) |
| Indicações clínicas | Chronic total occlusions, tight stenoses, calcific occlusions in fem-pop & BTK vasculature |
Size & Ordering Matrix
| Tamanho francês | Usable Length (cm) | Guidewire | Tip Shape | Código do produto | Notas |
| 2.4 – 2.6 | 65 / 90 / 135 | 0.014” | Straight, Tapered | DPH-2.6-XX-014 | Suited for BTK interventions requiring flexible distal tip and stable proximal support |
| 2.4 – 2.6 | 100 / 150 | 0.014” | Straight, Tapered | DPH-2.6-XX-014 | Extended length for deeper lesions in SFA or popliteal region |
| 3.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 4.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 5.0 | 80 / 135 / 150 | 0.018" | Slight Angled (option) | DPH-3.0-XX-018 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 6.0 | 80 / 135 / 150 | 0.035” | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
| 7.0 | 80 / 135 / 150 | 0.035” | Slight Angled (option) | DPH-3.0-XX-035 | Larger internal diameter for enhanced pushability and crossing in more robust vessel segments |
Produtos Relacionados
-

Cateteres de infusão valvulados Viper™
Ler maisO Cateter de Infusão Valvulado Viper™ é um monolúmen, ponta valvulada sistema de entrega que oferece a flexibilidade de infundir agentes anti-trombos, contraste radiopaco ou outras soluções farmacológicas especificadas pelo médico com ou sem um fio-guia no local.
-

Cateter de suporte de cruzamento de baixo perfil Dolphin PRO
Ler maisA de baixo perfil cateter de cruzamento com capacidade de empurrar e rastreabilidadeConcebido para apertado ou fortemente calcificado lesões nas artérias coronárias ou periféricas.
-

Atlas Endovascular Peripheral Stent Graft (Endovascular Peripheral Stent Graft)
Ler maisA stent periférico revestido oferta de enxertos seguro oclusão de aneurismas ou lesões oclusivas em ilíaco ou femoral segmentos, reduzindo o risco de rutura ou reoclusão.
-

Sistema de stent periférico Atlas
Ler maisUm robusto stent periférico plataforma concebida para femoral, ilíaco, ou poplítea lesões, assegurando adequado suporte radial e baixo taxas de reestenose em intervenções na DAP.