InWIRE 0.014” & 0.018” CTO Guidewire
A range of high-performance guidewires offering durable nitinol or stainless cores, hydrophilic coatings, and multiple tip shapes for crossing calcified or complex coronary & peripheral lesions.
InWIRE® is a recanalization guidewire system specifically crafted to facilitate the insertion of catheters and interventional medical devices in challenging vascular lesions, particularly in cases of chronic total occlusion (CTO). By combining hydrophilic coating, torque control, and a flat, malleable tip, InWIRE aims to enhance steerability, pushability, and precision in complex anatomical pathways.
Flat, Malleable Tip
- Customizable Shaping: The tip can be bent or angled to navigate tortuous vessels and tight occlusions.
- Tactile Feedback: Physicians experience improved tip response, aiding in precise lesion crossing.
Hydrophilic Polymer Coating
- Low Friction: Minimizes resistance in heavily calcified or fibrotic lesions, reducing the risk of wire-induced trauma.
- Enhanced Trackability: Facilitates smooth passage through narrow segments, supporting faster lesion penetration and fewer wire exchanges.
Radiopaque Tip
- Clear Fluoroscopic Visualization: Real-time visibility of the wire tip promotes safer lesion navigation and helps avoid dissection planes or perforation.
- Accurate Positioning: Confidence in wire tip location reduces procedural guesswork and shortens total procedure time.
Torque Capability
- 360-Degree Steerability: Balanced torque transfer from the proximal shaft ensures stable manipulation in CTO recanalization.
- Reduced Wire Buckling: Construction designed to withstand rotational forces, preserving wire integrity during prolonged procedures.
Multiple Diameter Options
- 0.014” & 0.018”: Addresses various interventional needs, from coronary vessels (common for 0.014”) to peripheral arteries (common for 0.018”).
General Product Specifications
Specification | Detail / Value |
Product Name | InWIRE PTCA Guidewires |
Intended Use | Coronary interventions (e.g., PTCA, stent placement) requiring wire-based navigation under fluoroscopy |
Core Material | Stainless Steel or Nitinol core (depending on variant) |
Coating Options | Hydrophilic, hydrophobic, or hybrid coatings |
Distal Tip Style | Floppy, Intermediate, Stiff, etc. (varies by product code) |
Nominal Diameter | 0.014” (Primary PTCA standard) |
Overall Length Range | Typically 180 cm, 190 cm, 300 cm (varies by product code) |
Tip Load | Light (1–3 g), Intermediate (4–6 g), High (7–12 g) or as per your grading scale |
Radiopaque Distal | Distal 2–3 cm with tungsten/platinum coil for fluoroscopic visibility |
Sterility | Sterile (EO) |
Single Use | Yes |
Shelf Life | 2–3 years (typical) |
Operating Temperature | 15–25 °C recommended storage |
Clinical Indications | Coronary lesion crossing, CTO approach, stent delivery, balloon placement |
Contraindications | Extreme vessel tortuosity/calcification beyond safe wire advancement, known wire material allergies |
InWIRE 0.014”, 180 cm Length
Core Dia | Length (cm) | Tip Style | Coating | Distal Radiopacity | Product Code | Notes |
0.014” | 180 | Floppy | Hydrophilic | 3 cm platinum coil | INW-014-180-F-H3 | Best for tortuous or small vessel approach |
0.014” | 180 | Floppy | Hydrophobic | 3 cm platinum coil | INW-014-180-F-HB3 | Minimal friction coating |
0.014” | 180 | Intermediate | Hydrophilic | 4 cm tungsten coil | INW-014-180-I-H4 | Balanced tip load, good push + track |
0.014” | 180 | Intermediate | Hybrid | 4 cm tungsten coil | INW-014-180-I-Hy4 | Partial hydro distal, minimal friction proximal |
0.014” | 180 | Stiff | Hydrophilic | 5 cm platinum coil | INW-014-180-S-H5 | High tip load, suitable for moderate CTO lesions |
0.014” | 180 | Stiff | Hydrophobic | 5 cm platinum coil | INW-014-180-S-HB5 | Rigid approach with stable push in calcifications |
InWIRE 0.014”, 190 cm Length
Core Dia | Length (cm) | Tip Style | Coating | Distal Radiopacity | Product Code | Notes |
0.014” | 190 | Floppy | Hydrophilic | 3 cm platinum coil | INW-014-190-F-H3 | Slightly longer for deeper coronary use |
0.014” | 190 | Intermediate | Hydrophilic | 4 cm tungsten coil | INW-014-190-I-H4 | Balanced approach, standard tip load |
0.014” | 190 | Intermediate | Hydrophobic | 4 cm tungsten coil | INW-014-190-I-HB4 | Reduced friction, good for mild tortuosity |
0.014” | 190 | Stiff | Hydrophilic | 5 cm platinum coil | INW-014-190-S-H5 | High support wire, recommended for challenging CTO |
0.014” | 190 | Stiff | Hybrid | 5 cm platinum coil | INW-014-190-S-Hy5 | Partial hydro distal, stable push proximal |
0.014” | 190 | Floppy | Hydrophilic | 3 cm platinum coil | INW-014-190-F-H3 | Slightly longer for deeper coronary use |
InWIRE 0.014”, 300 cm Length
Core Dia | Length (cm) | Tip Style | Coating | Distal Radiopacity | Product Code | Notes |
0.014” | 300 | Floppy | Hydrophilic | 3 cm tungsten coil | INW-014-300-F-H3 | Extra-long wire for exchange or peripheral use |
0.014” | 300 | Floppy | Hydrophobic | 3 cm tungsten coil | INW-014-300-F-HB3 | Long wire, minimal friction surface |
0.014” | 300 | Intermediate | Hydrophilic | 4 cm platinum coil | INW-014-300-I-H4 | Balanced tip load + extended length for multi-steps |
0.014” | 300 | Intermediate | Hybrid | 4 cm tungsten coil | INW-014-300-I-Hy4 | Partial hydro on distal segment only |
0.014” | 300 | Stiff | Hydrophilic | 5 cm platinum coil | INW-014-300-S-H5 | High push wire for complex CTO crossing |
0.014” | 300 | Stiff | Hybrid | 5 cm platinum coil | INW-014-300-S-Hy5 | Maximum support in difficult anatomies |
Related products
-
Atlas Endovascular Peripheral Stent Graft
Read moreA covered peripheral stent graft offering secure occlusion of aneurysms or occlusive lesions in iliac or femoral segments, reducing risk of rupture or re-occlusion.
-
Extender PTCA Balloon Catheter
Read moreA standard high-pressure coronary balloon designed for lesion predilation or standalone angioplasty, offering precise inflation profiles and reduced crossing profiles.
-
Extender Drug PTA Balloon Catheter
Read moreA drug-coated balloon for peripheral transluminal angioplasty (PTA), releasing antiproliferative agents to mitigate restenosis in femoral or popliteal arteries.
-
Extender Drug Eluting PTCA Balloon Catheter Paclitaxel
Read moreA paclitaxel-coated coronary balloon catheter aimed at reducing restenosis during percutaneous transluminal coronary angioplasty (PTCA), ensuring effective drug delivery to the vessel wall.