HyperTiss Intracavitaire hypothermieset voor blaaskankerbehandeling
Een geavanceerd medisch systeem dat is ontworpen om gecontroleerde hypothermie rechtstreeks in de blaasholte toe te dienen, waardoor de therapeutische resultaten bij de behandeling van blaaskanker worden verbeterd door de gevoeligheid van de tumor voor chemotherapie te vergroten en het aantal recidieven te verminderen.
De HyperTiss Intracavitary Hypothermia Set offers a multifactorial approach to bladder tumor management by combining chemotherapy with targeted hyperthermia in a controlled, patient-friendly delivery system. Through a specialized Three-Way Foley Silicone Catheter and advanced temperature control technology, HyperTiss ensures precise thermal and drug regulation—optimizing chemo-hyperthermia’s efficacy against cancerous tissue within the bladder while prioritizing patient safety and comfort.
System Components & Design
Three-Way Foley Silicone Catheter
- High-Quality Silicone: Minimizes irritation to the bladder wall, promoting patient tolerance during extended intravesical therapy.
- Multi-Port Access: Enables drug instillation, temperature monitoring, and continuous fluid exchange with minimal instrumentation.
Connection Connectors & Two-Way Stopcock
- Secure Fluid Pathways: Prevents leakage or accidental disconnection, providing stable infusion and drainage ports for the anticancer solution.
- Two-Way Stopcock: Offers operator-friendly toggling between infusion, drainage, or sealed modes during the procedure.
Heat Probe
- Precise Temperature Regulation: Monitors and maintains fluid temperature within a 41–44°C range (±0.2°C) per physician protocol.
- Optimized Hyperthermia Delivery: Ensures uniform heat distribution across the bladder mucosa, enhancing drug uptake.
Clamp, Medical Grade PVC Tubing & Bag
- Fluid Management: Simplifies infusion, drainage, or recirculation processes for delivering heated chemotherapy solutions.
- Transparent & Latex-Free: Allows clinicians to observe fluid levels and flow conditions, supporting safe handling.
Silicone Tubing
- Flexible, Atraumatic: Minimizes mechanical stress on the bladder or the infusion line, enhancing patient safety and comfort.
- Biocompatible Construction: Resists kinking and maintains consistent fluid passage even under repeated bending.
Therapeutic Rationale: Chemo-Hyperthermia
Synchronized Temperature & Drug Delivery
- HypertISS: (Hypothermia might be a mis-labelling or it’s “HyperTiss” but anyway) By raising local tissue temperature to 41–44°C, the synergy between heat and chemotherapeutic solutions intensifies cancer cell death.
- Favorable Tissue Response: Hyperthermia triggers changes in tumor vasculature, enhancing chemotherapeutic penetration and susceptibility of malignant cells to cytotoxic agents.
Reduced Recurrence Rates
- Improved Oncologic Control: Enhanced tissue drug levels plus disruption of tumor cell defense mechanisms can lower progression or relapse of bladder tumors.
- Better Resource Allocation: Effective local therapy can lessen the need for extensive systemic treatments, cutting down cost and toxicity profiles.
Clinical Advantages & Indications
Enhancing Chemotherapy Efficacy
- Targeted Hyperthermia: Elevates local temperature in the bladder to potentiate chemotherapeutic effects, thereby improving tumor cell kill rates.
- Increased Drug Penetration: Heated environment encourages deeper and more consistent uptake of anticancer agents.
Multifactorial Mode of Action
- Combination of Heat & Ionized Molecule Delivery: Creates a synergy that overcomes drug resistance and fosters thorough coverage of bladder lesions.
- Reduced Systemic Toxicity: Local administration confines drug exposure mainly to the bladder region, potentially lowering systemic side effects.
User-Friendly & Patient-Centric
- Outpatient/Local Anesthesia: Many procedures can be performed on a short-stay basis, optimizing hospital resources and improving patient quality of life.
- Reliable Monitoring & Control: Comprehensive alarm systems plus real-time temperature feedback maintain high standards of safety.
Robust Safety Measures
- Automatic Safety Shutdown: Mitigates risk if unexpected temperature or pressure fluctuations occur.
- Alarm Alerts: Minimizes operator error and ensures the procedure remains within the safe therapeutic window.
Gerelateerde producten
-
UroGlide Ureterale katheters
Lees meerDeze katheters zijn ontworpen voor soepele en betrouwbare navigatie en zorgen voor efficiënte drainage en toegang tijdens urologische procedures, waarbij trauma tot een minimum wordt beperkt en het comfort voor de patiënt wordt geoptimaliseerd.
-
Renova Nefrostomiesysteem
Lees meerEen gespecialiseerd systeem ontworpen voor percutane nefrostomieprocedures, dat betrouwbare drainage en toegang tot het nierbekken biedt met verbeterde precisie, comfort voor de patiënt en efficiëntie van de procedure.
-
ATLAS Drug Eluting Coronary Stent-systeem Kobaltchroom
Lees meerA kobalt-chroom coronaire stent die levert duurzame radiale sterkte en uitstekende traceerbaarheidgeschikt voor complex of verkalkt coronaire laesies met minimale terugslag.
-
Atlas coronair stentprothesesysteem
Lees meerA bedekte coronaire stent systeem dat extraluminaal afdichten perforaties of pseudoaneurysma'sDe coronaire patency behouden en extravasatie voorkomen.