Atlas Venous Stent
A specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
De Atlas™ Venous Stent, introduced by Uitgenodigd-a wereldwijde fabrikant van medische hulpmiddelen—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a zelfexpanderend nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting duurzaam patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Contra-indicaties
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
Specificatie | Detail / Waarde |
Productnaam | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
Inzetmechanisme | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
Radiale kracht | Moderate to high, designed to resist extrinsic compression |
Stent diameterbereik | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
Radiopake markers | Proximal and distal markers for fluoroscopic visualization |
Steriliteit | Sterile, single use |
Houdbaarheid | ~3–5 years if stored at 15–25 °C |
Klinische indicaties | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | Productcode | Opmerkingen |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
Gerelateerde producten
-
VascuVac Ai-ondersteunde vacuümtrombectomietechnologieën
Lees meerEen innovatief systeem met AI-ondersteunde technologie voor efficiënte vacuümtrombectomie, ontworpen om trombi snel verwijderen uit bloedvaten, De bloedstroom herstellen, en procedurele risico's minimaliseren bij vasculaire interventies.
-
Nexus Venous & Arterial Cannula
Lees meerMultipurpose veneus en slagader cannulae supporting extracorporeal circulation during cardiopulmonary bypass or ECMO, ensuring optimal flow rates en hemocompatibility.
-
Inca Trellis Thrombolysis System
Lees meerA catheter delivering thrombolytic agents while filter protection prevents distal embolization, ensuring safer pharmacologic dissolution of clots.
-
AngioHAND Clot Removal Catheter
Lees meerA hand-manipulated mechanical aspiration device enabling immediate clot extraction through a manual vacuum approach, simplifying acute thrombectomy procedures.