Keeper Endovascular Snare by INVAMED is a single-use, sterile device engineered to capture and retrieve intravascular foreign objects, from dislodged stents or guidewire fragments to thrombosis and other undesirable materials in the vascular system. With an innovative loop design and low-profile catheter introduction, the Keeper Snare provides precise control, maximum radial force, and minimized trauma—streamlining procedures in both arterial and venous settings.
Flexible Snare Loop Geometry
- Constructed from high-tensile nitinol or stainless-steel wires in various loop diameters for optimal capture potential.
- Retains shape memory and radial strength even after multiple manipulation cycles, supporting consistent retrieval.
Ergonomic Catheter Delivery
- Low-profile catheter sheath simplifies femoral, radial, or brachial access.
- Catheter tip and snare loop are radiopaque, facilitating fluoroscopic or angiographic visualization and precise target approach.
Enhanced Capture and Control
- The snare loop compresses or expands under operator control, securely gripping foreign bodies or occlusive elements without risk of fragmenting them further.
- A dedicated handle or torque device (depending on model) provides precision in loop rotation and retraction.
Minimally Invasive Retrieval
- Reduces or eliminates the need for open surgical extraction, shortening patient recovery times and lowering complication risks.
- Effective for broken guidewires, catheter fragments, or other intraluminal materials that must be removed promptly to avoid embolization or vascular injury.
Broad Range of Indications
- Suitable for arterial or venous retrieval in peripheral vessels, central vasculature, or even select cardiac chambers if indicated.
- Helpful in addressing intravascular coil misplacements, filter retrievals, or spontaneous foreign body presence.
제품 사양
| 사양 | 세부 정보 / 값 |
| 제품 이름 | Keeper 혈관 내 스네어 |
| 사용 목적 | Retrieval of foreign bodies, dislodged stents, or thrombus fragments from vascular lumens |
| Snare Material | Nitinol or Stainless Steel loop with radiopaque marker |
| Loop Diameter Range | ~2–35 mm (depending on vessel size) |
| Shaft Length | 80–120 cm (various) |
| 가이드 와이어 호환성 | 0.018” or 0.035” (check model) |
| Sheath Compatibility | 4–6F typical |
| 무균 | 멸균, 일회용 |
| 유통 기한 | ~3 years, 15–25 °C storage |
주문 및 사이즈 매트릭스
| Loop Diameter (mm) | Shaft Length (cm) | Guidewire Size | 제품 코드 |
| 5 | 80 | 0.018" | KEE-5-80-018 |
| 10 | 80 | 0.018" | KEE-10-80-018 |
| 15 | 100 | 0.035" | KEE-15-100-035 |
| 20 | 100 | 0.035" | KEE-20-100-035 |
| 25 | 120 | 0.035" | KEE-25-120-035 |
| 35 | 120 | 0.035" | KEE-35-120-035 |
연관 상품
-

InWIRE PTCA 가이드 와이어
더 보기다양한 고성능 관상동맥 가이드 와이어 제공 내구성 니티놀 또는 스테인리스 코어, 친수성 코팅 및 교차용 다중 팁 모양 석회화 또는 복합 관상동맥 병변.
-

SteerCATH 조종 가능한 카테터
더 보기A 조종 가능 지원 카테터 편향 가능 팁, 복잡하거나 분기 용기 관상동맥 및 말초 중재술에서 접근성을 높입니다. 까다로운 해부학적 구조에서 교차 성공률을 높입니다.
-

Atlas 대동맥 스텐트 그라프트
더 보기A 커버 스텐트 시스템 혈관 내 대동맥류 수술을 통해 대동맥류 주머니의 가압을 방지하고 안전한 내강 개통을 가능하게 합니다.
-

Stena 대동맥 다층 유량 조절기
더 보기전문화된 다층 스텐트 다음과 같이 설계되었습니다. 대동맥 흐름 조절를 사용하여 중요한 가지 관류를 방해하지 않고 주머니 압력을 낮추고 동맥류를 안정화합니다. 혈류 역학을 재구성하도록 설계되었습니다. 흉부 대동맥 또는 복부 대동맥 병변을 개선하여 장기적인 결과를 개선합니다.