The Dolphin Sub-Intimal Entry Catheter, by Invamed—a global medical device manufacturer—is uniquely designed to assist in subintimal dissection and re-entry in chronic total occlusions (CTOs) or heavily diseased vascular segments. By providing a targeted pathway to the subintimal space and then guiding re-entry into the true lumen, Dolphin enhances procedural success in complex peripheral or coronary interventions.
Dedicated Subintimal Navigation
Engineered tip or “needle” design helps negotiate the subintimal plane, enabling operators to bypass occlusive lesions.
True Lumen Re-Entry
Specialized distal tip geometry assists in precision re-entry to the true lumen, improving success rates in otherwise intractable CTOs.
High Pushability & Torque
Braided or coiled shaft construction delivers robust force transmission for crossing tough plaque or calcifications.
Hydrophilic Coating (optional)
Minimizes friction against vessel walls, reducing dissection risk and procedural time in challenging anatomies.
Wide Clinical Utility
Indicated for peripheral artery disease (PAD) with occlusive lesions, especially superficial femoral or popliteal arteries. May also be adapted for select coronary interventions.
금기 사항
Extremely tortuous vessels, advanced dissection risk, or patient conditions that preclude subintimal techniques.
일반 제품 사양
사양 | 세부 정보 / 값 |
제품 이름 | Dolphin 아-내막 진입 카테터 |
사용 목적 | Facilitates subintimal dissection and re-entry in chronic total occlusion (CTO) or heavily diseased vessels (peripheral or coronary) |
카테터 디자인 | Specially shaped distal tip or “re-entry” needle to access the true lumen from a subintimal plane |
재료 | Pebax/Polyamide shaft with braided reinforcement, possible radiopaque or tungsten tip |
Outer Diameter (Fr) | ~2.0–3.5 Fr for coronary or ~3.5–4.5 Fr for peripheral usage (adjust as appropriate) |
내부 루멘 | Typically 0.014” guidewire compatibility |
작업 길이 | ~80–150 cm (varies by product code) |
팁 구성 | Tapered, angled, or “needle” re-entry tip, radiopaque marker for precise subintimal guidance |
Marker Bands | 1–2 near the distal segment for fluoroscopic visualization |
Sheath Compatibility | 4F–6F (small coronary variants), 5F–7F (peripheral variants) |
무균 | 멸균(에틸렌 옥사이드) |
1회 사용 | 예 |
유통 기한 | ~2–3 years if stored in sealed packaging at 15–25 °C |
임상 적응증 | Re-entering true lumen in CTOs, subintimal approach in peripheral arteries (e.g., superficial femoral), or advanced coronary CTO crossing |
금기 사항 | Extremely tortuous or heavily calcified vessels, known device material allergies, or situations unsuited for subintimal strategy |
Dolphin 아-내막 진입 카테터
Fr Size | 작업 길이(cm) | Tip Style | 제품 코드 | 참고 |
2.0 Fr | 80 | Tapered (Needle Tip) | DOL-SI-2.0-80-TP | Ultra-low profile for coronary subintimal re-entry |
2.0 Fr | 100 | Angled Needle | DOL-SI-2.0-100-AN | Slightly angled tip, moderate length |
2.3 Fr | 80 | Straight “Re-Entry” | DOL-SI-2.3-80-ST | Balanced OD for small peripheral or coronary usage |
2.3 Fr | 135 | Tapered (Needle Tip) | DOL-SI-2.3-135-TP | Extended length, deeper CTO crossing |
2.6 Fr | 100 | Angled “Re-Entry” | DOL-SI-2.6-100-AN | Mid-range OD plus angled tip for subintimal SFA approach |
2.6 Fr | 135 | Straight “Re-Entry” | DOL-SI-2.6-135-ST | Long length for complicated multi-segment occlusions |
3.0 Fr | 100 | Tapered (Needle Tip) | DOL-SI-3.0-100-TP | Slightly larger OD for peripheral subintimal re-entry |
3.0 Fr | 135 | Angled “Re-Entry” | DOL-SI-3.0-135-AN | Extended length, angled tip for advanced re-entry strategy |
3.5 Fr | 100 | Straight Needle | DOL-SI-3.5-100-ST | Larger OD for robust push in heavily calcified vessels |
3.5 Fr | 135 | Tapered (Needle Tip) | DOL-SI-3.5-135-TP | Max length for tall patients or extensive subintimal navigation |
4.0 Fr | 135 | Angled “Re-Entry” | DOL-SI-4.0-135-AN | (If your line extends to 4.0 Fr or beyond for large peripheral usage) |
연관 상품
-
TemREN PRO 죽상 절제술 시스템
더 보기TemREN PRO 죽상 절제술 시스템; A 회전 또는 방향성 다음에 특화된 죽상 절제술 장치 플라그 절제 말초 동맥의 혈류량을 증가시켜 루멘 기압 외상을 최소화하면서 복원할 수 있습니다.
-
Keeper 혈관 내 스네어
더 보기A 멀티 루프 스네어 검색 장치 이물질 또는 색전증 캡처하여 보안 참여 및 출금 혈관 내강에서
-
TemREN 말초 죽상 절제술 시스템
더 보기A 회전 또는 방향성 다음에 특화된 죽상 절제술 장치 플라그 절제 말초 동맥의 혈류량을 증가시켜 루멘 기압 외상을 최소화하면서 복원할 수 있습니다.
-
Stena 주변기기용 멀티 레이어 유량 변조기
더 보기흐름 전환 스텐트 용 주변기기 동맥, 재분배 층류 병든 혈관 세그먼트에서 흘러나와 동맥류 또는 측부 혈관 보존을 돕습니다.