Atlas Venous Stent
A specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
The Atlas™ Venous Stent, introduced by Зақымданған—а жаһандық медициналық құрылғы өндірушісі—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a өзін-өзі кеңейту nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting төзімді patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Қарсы көрсеткіштер
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
Техникалық сипаттама | Мәліметтер / Мән |
Өнім атауы | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
Орналастыру механизмі | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
Радиалды күш | Moderate to high, designed to resist extrinsic compression |
Стент диаметрінің диапазоны | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Стент ұзындығы диапазоны | ~40–120 mm, accommodating short or long-segment lesions |
Радиопакалық маркерлер | Proximal and distal markers for fluoroscopic visualization |
Стерилділік | Sterile, single use |
Жарамдылық мерзімі | ~3–5 years if stored at 15–25 °C |
Клиникалық көрсеткіштер | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Стент ұзындығы (мм) | Sheath Compatibility (F) | Өнім коды | Ескертпелер |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
Қатысты өнімдер
-
ICT Ішкі компрессиялық терапия
Толығырақ оқыңызICT Valvular Leak Sealer Reconstruction System
ICT is an Internal Compression Therapy for dysfunctioning vein valves. The procedure is also called percutaneous valvuloplasty.
-
Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
Толығырақ оқыңызА айналмалы system featuring a leaf tip design for механикалық clot fragmentation plus strong aspiration capabilities in deep venous or arterial occlusions.
-
ThermoBLOCK Варикозды тамырлардың радиожиілік абляция жүйесі
Толығырақ оқыңызА радиожиілік үшін абляция платформасы қабілетсіз беткейлік веналар, ұсыну термиялық жеңілдету үшін сафенозды немесе перфорациялық веналарды жабу варикозды белгілері.
-
Viper™ Valved Infusion Catheters
Толығырақ оқыңызThe Viper™ Valved Infusion Catheter болып табылады single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with немесе without a guidewire in place.