Atlas Venous Stent

A specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.

The Atlas™ Venous Stent, introduced by Зақымданған—а жаһандық медициналық құрылғы өндірушісі—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a өзін-өзі кеңейту nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting төзімді patency in challenging venous anatomies.

Self-Expanding Nitinol Framework

Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.

Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.

Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.

Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.

Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.

Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.

Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.

Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.

Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.

Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.

Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.

Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.

Technical Specifications

Техникалық сипаттама Мәліметтер / Мән
Өнім атауы Atlas™ Venous Stent
Stent Material Nitinol (nickel-titanium) self-expanding alloy
Орналастыру механизмі Over-the-wire via introducer sheath (typically 6F–9F, model-specific)
Радиалды күш Moderate to high, designed to resist extrinsic compression
Стент диаметрінің диапазоны ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes
Стент ұзындығы диапазоны ~40–120 mm, accommodating short or long-segment lesions
Радиопакалық маркерлер Proximal and distal markers for fluoroscopic visualization
Стерилділік Sterile, single use
Жарамдылық мерзімі ~3–5 years if stored at 15–25 °C
Клиникалық көрсеткіштер Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency

Size & Ordering Matrix

Stent Diameter (mm) Стент ұзындығы (мм) Sheath Compatibility (F) Өнім коды Ескертпелер
10 40 6F AVS-10x40-6F Smaller diameter for narrower veins or moderate lesions
10 60 6F AVS-10x60-6F Slightly longer coverage in the same diameter
14 60 7F AVS-14x60-7F Popular mid-range diameter for common iliofemoral lesions
14 80 7F AVS-14x80-7F Extended length for multi-segment stenoses
16 80 8F AVS-16x80-8F Enhanced diameter for advanced venous outflow compromise
16 100 8F AVS-16x100-8F Longer coverage in larger veins
20 120 9F AVS-20x120-9F Maximum diameter & length for extensive venous pathology