Spider™ Peripheral Detachable Coil System (Detachable Pushable)
A detachable coil kit for embolization of peripheral aneurysms, AV fistulas, or abnormal vessels, providing stable coil packing with 統制された mechanical detachment.
The Spider™ Peripheral Detachable Coil System in its detachable pushable configuration is engineered by Invamed—a global medical device manufacturer—to address peripheral aneurysm occlusion, vascular malformations, or fistulae requiring controlled coil placement. By offering a pushable yet detachable delivery mechanism, Spider™ affords the precision of in-place detachment without the complexity of electrolytic release, optimizing procedural control and reducing risk of coil migration.
Detachable Pushable Delivery
Combines the ease of a pushable coil insertion with the detachment control typically associated with mechanical or electrolytic systems, enabling safe retrieval or repositioning before final deployment.
Platinum Coil
High radiopacity ensures real-time fluoroscopic monitoring, helping interventionalists confirm accurate coil positioning and packing density.
Soft & Conformable
The flexible coil design adapts to complex vessel anatomies or aneurysmal sacs, minimizing stress on fragile vessel walls.
Versatile Embolization
Ideal for small-to-moderate peripheral aneurysms, arteriovenous malformations (AVMs), or abnormal vascular communications, delivering precise occlusion.
適応症
Aneurysm repair (e.g., peripheral, visceral), AVM or fistula occlusion in peripheral territories, or general endovascular procedures requiring dense coil packing.
禁忌事項
Vessels too small or tortuous to pass the delivery catheter, active infection at the access site, or scenarios where coil retrieval is not feasible.
製品仕様
| 仕様 | 詳細 / 価値 |
| 製品名 | Spider Peripheral Detachable Coil System |
| 使用目的 | Endovascular embolization of peripheral aneurysms, AV fistulas, or abnormal vessels |
| Coil Material | Platinum or platinum-tungsten alloy with detachable mechanism |
| Detachment Method | Mechanical or electrolytic (verify final model) |
| Coil Diameter Range | ~1.5–20 mm (varies by catalog code) |
| Coil Length Range | ~1–40 cm (depending on coil diameter and framing vs. filling type) |
| Delivery Microcatheter | Typically 2.3–2.7F inner diameter, 0.016–0.021” ID |
| ラジオパシティ | Platinum coil for fluoroscopic visualization |
| 不妊症 | 滅菌済み、シングルユース |
| 賞味期限 | ~3–5 years at 15–25 °C |
| 臨床適応症 | Peripheral aneurysm occlusion, AVF closure, selective vessel sacrifice |
| 禁忌事項 | Vessels too small or tortuous to accommodate microcatheter, known device material allergies |
オーダー&サイズマトリックス
| Coil Diameter (mm) | Coil Length (cm) | Detachment Type | 商品コード | 備考 |
| 1.5 | 2 | Mechanical | SPD-P-1.5x2-M | Very small coil for micro-aneurysms |
| 1.5 | 4 | Electrolytic | SPD-P-1.5x4-E | Extended length, small diameter |
| 3.0 | 10 | Mechanical | SPD-P-3.0x10-M | Mid-range coil diameter, framing type |
| 3.0 | 15 | Electrolytic | SPD-P-3.0x15-E | Longer filling coil for larger sac |
| 5.0 | 15 | Mechanical | SPD-P-5.0x15-M | Medium coil for moderate aneurysms |
| 5.0 | 20 | Electrolytic | SPD-P-5.0x20-E | Extended coil length, filling type |
| 10.0 | 20 | Mechanical | SPD-P-10.0x20-M | Larger diameter coil for bigger aneurysms |
| 10.0 | 40 | Electrolytic | SPD-P-10.0x40-E | Maximum length coil for large-volume occlusion |
関連商品
-

Pars 着脱式塞栓用カテーテル
続きを読むA カテーテル システム有効化 選択的 マイクロカテーテルの前進と 機械的 または ケミカル 塞栓術、遠位 取り外し可能 カテーテルの巻き込みを避けるためのヒント。
-

Extender PTCAバルーンカテーテル
続きを読むA 標準 高圧 冠状動脈バルーン を想定している。 病変前置脱毛 またはスタンドアロン 血管形成術正確な膨張プロファイルと交差プロファイルの低減を提供する。
-

Hero 機械式鉛除去システム
続きを読むA 機械的 代替 鉛抽出専用のロック式スタイレットやシースを使用する。 ずらす 線維性付着物の確保 着実 安全に取り外すための牽引力。
-

TemREN ロータブレーター
続きを読むA 回転 血栓除去またはアテレクトミー・システム 高速 には グラインド あるいは石灰化したプラークを除去し、ステント留置のための内腔拡大を確保する。