Spider™ Peripheral Detachable Coil System (Detachable Pushable)
A detachable coil kit for embolization of peripheral aneurysms, AV fistulas, or abnormal vessels, providing stable coil packing with 統制された mechanical detachment.
The Spider™ Peripheral Detachable Coil System in its detachable pushable configuration is engineered by Invamed—a global medical device manufacturer—to address peripheral aneurysm occlusion, vascular malformations, or fistulae requiring controlled coil placement. By offering a pushable yet detachable delivery mechanism, Spider™ affords the precision of in-place detachment without the complexity of electrolytic release, optimizing procedural control and reducing risk of coil migration.
Detachable Pushable Delivery
Combines the ease of a pushable coil insertion with the detachment control typically associated with mechanical or electrolytic systems, enabling safe retrieval or repositioning before final deployment.
Platinum Coil
High radiopacity ensures real-time fluoroscopic monitoring, helping interventionalists confirm accurate coil positioning and packing density.
Soft & Conformable
The flexible coil design adapts to complex vessel anatomies or aneurysmal sacs, minimizing stress on fragile vessel walls.
Versatile Embolization
Ideal for small-to-moderate peripheral aneurysms, arteriovenous malformations (AVMs), or abnormal vascular communications, delivering precise occlusion.
適応症
Aneurysm repair (e.g., peripheral, visceral), AVM or fistula occlusion in peripheral territories, or general endovascular procedures requiring dense coil packing.
禁忌事項
Vessels too small or tortuous to pass the delivery catheter, active infection at the access site, or scenarios where coil retrieval is not feasible.
製品仕様
仕様 | 詳細 / 価値 |
製品名 | Spider Peripheral Detachable Coil System |
使用目的 | Endovascular embolization of peripheral aneurysms, AV fistulas, or abnormal vessels |
Coil Material | Platinum or platinum-tungsten alloy with detachable mechanism |
Detachment Method | Mechanical or electrolytic (verify final model) |
Coil Diameter Range | ~1.5–20 mm (varies by catalog code) |
Coil Length Range | ~1–40 cm (depending on coil diameter and framing vs. filling type) |
Delivery Microcatheter | Typically 2.3–2.7F inner diameter, 0.016–0.021” ID |
ラジオパシティ | Platinum coil for fluoroscopic visualization |
不妊症 | 滅菌済み、シングルユース |
賞味期限 | ~3–5 years at 15–25 °C |
臨床適応症 | Peripheral aneurysm occlusion, AVF closure, selective vessel sacrifice |
禁忌事項 | Vessels too small or tortuous to accommodate microcatheter, known device material allergies |
オーダー&サイズマトリックス
Coil Diameter (mm) | Coil Length (cm) | Detachment Type | 商品コード | 備考 |
1.5 | 2 | Mechanical | SPD-P-1.5x2-M | Very small coil for micro-aneurysms |
1.5 | 4 | Electrolytic | SPD-P-1.5x4-E | Extended length, small diameter |
3.0 | 10 | Mechanical | SPD-P-3.0x10-M | Mid-range coil diameter, framing type |
3.0 | 15 | Electrolytic | SPD-P-3.0x15-E | Longer filling coil for larger sac |
5.0 | 15 | Mechanical | SPD-P-5.0x15-M | Medium coil for moderate aneurysms |
5.0 | 20 | Electrolytic | SPD-P-5.0x20-E | Extended coil length, filling type |
10.0 | 20 | Mechanical | SPD-P-10.0x20-M | Larger diameter coil for bigger aneurysms |
10.0 | 40 | Electrolytic | SPD-P-10.0x40-E | Maximum length coil for large-volume occlusion |
関連商品
-
GuideX延長カテーテル
続きを読むアン エクステンション または「母子」カテーテルの提供 サポート強化 そして リーチ 曲がりくねった、あるいは 遠位 冠動脈/末梢セグメント、安定したデバイスナビゲーションを可能にする。
-
Texten: 高機能シアノアクリレート組織接着剤
続きを読む創傷閉鎖や外科手術用に開発された速効性の生体適合性接着剤で、強力な組織接着、瘢痕形成の軽減、縫合糸やステープルに代わる効果的な選択肢を提供する。
-
Extender 薬剤溶出PTCAバルーンカテーテル パクリタキセル
続きを読むA パクリタキセルコート 冠動脈バルーンカテーテル 再狭窄の減少 経皮経管冠動脈形成術(PTCA)の際に、血管壁への効果的な薬物送達を確実にする。
-
Heroレーザー鉛除去システム
続きを読むA レーザーベース 抽出装置 精密 そして セーフ 除去 心臓リード (ペースメーカーまたはICD)の感染症、リードの故障、またはアップグレードの場合。