MultiBEAM Inferior Vena Cava (IVC) Filter
A convertible or retrievable IVC filter preventing pulmonary emboli by intercepting clots traveling through the inferior vena cava, ensuring safety in high-risk patients.
The MultiBEAM Inferior Vena Cava (IVC) Filter, offered by Invamed—a global medical device manufacturer—is designed to capture and retain thromboembolic fragments traveling within the venous system, thereby reducing the risk of pulmonary embolism (PE). Featuring a self-expanding metallic framework, MultiBEAM provides robust fixation in the IVC while facilitating high patency and stable clot containment.
Self-Expanding Nitinol Struts
Engineered from a biocompatible alloy for secure anchoring, even under shifting venous pressures.
Multi-Spoke or “Beam” Design
Creates multiple capture zones that efficiently trap emboli without significantly restricting blood flow, sustaining venous return.
Retrievable/Optional Permanent
Certain models allow retrieval within a designated window, while others function as permanent PE prophylaxis solutions—offering clinicians flexibility in management.
Reduced Migration & Tilt
Precisely balanced struts help prevent filter migration or tilting, enhancing performance consistency over time.
Wide Application Scope
Indicated for patients at elevated PE risk due to venous thromboembolism (VTE), inadequate response to anticoagulants, or temporary contraindications to anticoagulation therapy.
禁忌事項
Excessively narrow or tortuous IVC diameter preventing secure seating, active infection at insertion site, or patient-specific anatomical constraints.
製品仕様
仕様 | 詳細 / 価値 |
製品名 | MultiBEAM Inferior Vena Cava (IVC) Filter |
使用目的 | Prevention of pulmonary embolism by capturing clots traveling from lower extremity or pelvic veins |
Filter Design | Self-expanding metal struts (Nitinol or stainless steel) arranged in a multi-beam pattern |
展開メカニズム | Over-the-wire or sheath-based insertion, typically via femoral or jugular access |
Retrieval Option | Some models are optionally retrievable within a specific timeframe (check product line) |
Filter Diameter Range | Suited for IVC diameters ~20–30 mm (varies by product code) |
放射線不透過性マーカー | Distal apex or anchor tips for fluoroscopic identification |
MRの互換性 | MR Conditional (verify labeling) |
不妊症 | 滅菌済み、シングルユース |
賞味期限 | ~3–5 years if stored at 15–25 °C in sealed packaging |
臨床適応症 | Patients at risk of pulmonary embolism (PE), especially with contraindications to anticoagulation |
禁忌事項 | Severe IVC anatomical anomalies, high-level occlusion, known allergy to device materials |
オーダー&サイズマトリックス
IVC Diameter Suitability (mm) | Filter Apex to Anchor (mm) | Retrieval Window (days) | 商品コード | 備考 |
< 24 | 26 | 30 | MBI-<24-40-30 | Smaller IVC or narrow diameters |
< 24 | 26 | 90 | MBI-<24-50-90 | Extended retrieval time |
20–28 | 33 | 30 | MBI-20-28-50-30 | Common range for standard IVC diameters |
20–28 | 33 | 90 | MBI-20-28-60-90 | Longer apex distance + extended retrieval |
28–30 | 33 | 30 | MBI-28-30-60-30 | For larger IVC diameter, shorter retrieval |
28–30 | 33 | 90 | MBI-28-30-70-90 | Largest apex span + extended retrieval |
関連商品
-
Inca® Embolism Protective System
続きを読むA catheter delivering thrombolytic agents while filter protection prevents distal embolization, ensuring safer pharmacologic dissolution of clots.
-
Venablock™静脈瘤治療静脈閉鎖システム
続きを読むVenablock™静脈瘤治療静脈閉鎖システム; A シアノアクリレート系 静脈閉鎖システム 軽薄 静脈不全, 分娩 非熱 最小限の局所麻酔で閉塞し 速い 手術後の回復。
-
AngioHAND Clot Removal Catheter
続きを読むA hand-manipulated mechanical aspiration device enabling immediate clot extraction through a manual vacuum approach, simplifying acute thrombectomy procedures.
-
Mantis XP Thrombectomy System for Fistula
続きを読むA high-powered mechanical thrombectomy device for deep venous or arterial occlusions, supporting extended reach and robust clot extraction in complex anatomies.