Mantis Trombectomia rotazionale con punta a foglia e ultraaspirazione

A rotazionale sistema che presenta un punta della foglia progettazione per meccanico frammentazione del coagulo più forte capacità di aspirazione in caso di occlusioni venose o arteriose profonde.

Il Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.

Leaf Tip Design
  • The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
  • Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
  • High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
  • Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
  • Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
  • Facilitates accurate positioning and ensures confident navigation through complex vascular pathways.
  • Available in 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
  • Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.

90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.

Specifiche del prodotto

Specifiche Dettaglio / Valore
Nome del prodotto Mantis Trombectomia rotazionale con punta a foglia e ultraaspirazione
Uso previsto Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems
Design del catetere Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal
Materiale Stainless steel or nitinol drive shaft, flexible polymer outer sheath
Rotational Speed Range ~40k–80k rpm (check final specs)
Aspiration Mechanism Over-the-wire suction or integrated vacuum line
Catheter Outer Diameter ~5–7F, depending on model and tip size
Lunghezza di lavoro ~80–120 cm (varies by product code)
Radiopacità Distal marker near leaf tip for precise positioning under fluoroscopy
Sterilità Sterile, monouso
Durata di conservazione ~2–3 years at 15–25 °C
Indicazioni cliniche Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT)
Controindicazioni Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials

Matrice di ordinazione e dimensioni

Diametro esterno (F) Lunghezza di lavoro (cm) Leaf Tip Diameter (mm) Codice prodotto Note
5F 80 5 MNT-LF-5F-80-5 Smaller tip for distal or smaller vessels
5F 100 5 MNT-LF-5F-100-5 Longer shaft, same leaf diameter
6F 80 6 MNT-LF-6F-80-6 Common size for peripheral artery usage
6F 120 6 MNT-LF-6F-120-6 Extended length for deeper or proximal segments
7F 100 7 MNT-LF-7F-100-7 Larger leaf tip for heavier thrombus loads
7F 120 7 MNT-LF-7F-120-7 Max length and larger tip for extensive clot burden