Horus® Sonde laser ottiche (fotocoagulazione)
A titanio o lega sistema di placche sternali che fornisce rigido fissazione dopo la sternotomia mediana, migliorando stabilità sternale e ridurre i rischi di infezione o deiscenza dopo un intervento di cardiochirurgia.
Il Horus® Optic Laser Probes by Invamed deliver high-performance photocoagulation capabilities for vitreoretinal surgery and other ophthalmic interventions. Constructed from medical-grade fiber optics, these probes offer precise laser energy transmission to the retina or posterior segment, ensuring effective photocoagulation with minimal scatter. Available in 20, 23, 25, or 27 gauge (0.81 mm, 0.64 mm, 0.50 mm, 0.41 mm), each probe caters to diverse procedural preferences and ocular anatomies.
Wide Range of Gauge Sizes
- 20G (0.81 mm), 23G (0.64 mm), 25G (0.50 mm), 27G (0.41 mm): Broad selection accommodates various surgical approaches—from standard vitrectomy ports to ultra-fine, minimally invasive surgeries.
- Surgeons can select the optimal gauge for patient-specific anatomy, pathology, and lens clarity.
High-Purity Fiber Optic Construction
- Fiber cables are derived from medical-grade fused silica or equivalent high-quality materials, ensuring superior light transmission and minimal dispersion.
- Enhanced photocoagulation precision reduces collateral tissue damage, crucial in delicate retinal structures.
Sterile & Disposable
- Probes come sterile and single-use, preventing cross-contamination and maintaining consistent optical performance.
- Simplifies OR workflow and eliminates the need for repeated reprocessing, reducing risk of fiber damage over multiple sterilization cycles.
Soft Tip & Angled Variants
- Certain models feature soft tip designs to safeguard against iatrogenic injury during retinal manipulations.
- Angled or curved tip options provide surgeons with improved access to peripheral or posterior pole lesions.
Versatile Laser Compatibility
- Standard endolaser coupling ensures broad compatibility with common ophthalmic laser systems (e.g., diode, argon).
- Color-coded or labeled connectors enable quick identification and safe, secure attachment during setup.
Indicazioni cliniche
- Retinal photocoagulation for diabetic retinopathy, macular edema, peripheral retina tears, lattice degeneration, or choroidal neovascular membranes.
- Vitreoretinal procedures requiring localized laser application—such as panretinal photocoagulation (PRP) or focal macular treatments.
Prodotti correlati
-

Atlas Venous Stent
Leggi tuttoA specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
-

Liposer per la liposuzione laser assistita
Leggi tuttoLiposer da Invamed è un piattaforma di liposuzione laser assistita progettato per fornire rimozione del grasso di precisione e maggiore contrazione dei tessuti nelle procedure estetiche e ricostruttive.
-

Peta Ablazione con radiofrequenza (RFA) per il dolore
Leggi tuttoUna precisione...sistema mirato progettato per erogare energia a radiofrequenza controllata per ablazione del nervoriducendo di fatto dolore cronico interrompendo il dolore trasmissione del segnale riducendo al minimo l'impatto sui tessuti circostanti. -

Peta Decompressione meccanica percutanea del disco
Leggi tuttoProgettato con materiali di precisione, questo dispositivo minimamente invasivo consente un'efficace decompressione dell'ernia del disco, alleggerendo la pressione sui nervi spinali e alleviando il dolore e favorendo un recupero più rapido.
