Mantis Trombectomia rotazionale con punta a foglia e ultraaspirazione
A rotazionale sistema che presenta un punta della foglia progettazione per meccanico frammentazione del coagulo più forte capacità di aspirazione in caso di occlusioni venose o arteriose profonde.
Il Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.
Leaf Tip Design
- The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
- Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
Nitinol Shaft with PA/PEBAX
- High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
- Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
Radiopaque Shaft Markings
- Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
- Facilitates accurate positioning and ensures confident navigation through complex vascular pathways.
Flexible Catheter Profiles
- Available in 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
- Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.
Multiple Catheter Lengths
90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.
Specifiche del prodotto
Specifiche | Dettaglio / Valore |
Nome del prodotto | Mantis Trombectomia rotazionale con punta a foglia e ultraaspirazione |
Uso previsto | Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems |
Design del catetere | Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal |
Materiale | Stainless steel or nitinol drive shaft, flexible polymer outer sheath |
Rotational Speed Range | ~40k–80k rpm (check final specs) |
Aspiration Mechanism | Over-the-wire suction or integrated vacuum line |
Catheter Outer Diameter | ~5–7F, depending on model and tip size |
Lunghezza di lavoro | ~80–120 cm (varies by product code) |
Radiopacità | Distal marker near leaf tip for precise positioning under fluoroscopy |
Sterilità | Sterile, monouso |
Durata di conservazione | ~2–3 years at 15–25 °C |
Indicazioni cliniche | Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT) |
Controindicazioni | Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials |
Matrice di ordinazione e dimensioni
Diametro esterno (F) | Lunghezza di lavoro (cm) | Leaf Tip Diameter (mm) | Codice prodotto | Note |
5F | 80 | 5 | MNT-LF-5F-80-5 | Smaller tip for distal or smaller vessels |
5F | 100 | 5 | MNT-LF-5F-100-5 | Longer shaft, same leaf diameter |
6F | 80 | 6 | MNT-LF-6F-80-6 | Common size for peripheral artery usage |
6F | 120 | 6 | MNT-LF-6F-120-6 | Extended length for deeper or proximal segments |
7F | 100 | 7 | MNT-LF-7F-100-7 | Larger leaf tip for heavier thrombus loads |
7F | 120 | 7 | MNT-LF-7F-120-7 | Max length and larger tip for extensive clot burden |
Prodotti correlati
-
Atlas Venous Stent
Leggi tuttoA specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
-
Sistema di ablazione a radiofrequenza per vene piccole VenoNeedle
Leggi tuttoA a basso consumo sistema termico finalizzato a vene a ragno, teleangectasie o piccole varici reticolari con preciso coagulazione, evitando grandi incisioni o tempi di inattività prolungati.
-
Dovi Catetere per l'aspirazione del trombo Ultra
Leggi tuttoA alto vuoto catetere di aspirazione per acuto o subacuto rimozione del trombo nei letti arteriosi o venosi, garantendo una rapida rivascolarizzazione con un rischio minimo di frammentazione.
-
Sistema di ablazione a radiofrequenza delle vene varicose ThermoBLOCK
Leggi tuttoA radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.