AngioHAND Clot Removal Catheter
A hand-manipulated mechanical aspiration device enabling immediate clot extraction through a manual vacuum approach, simplifying acute thrombectomy procedures.
The AngioHAND Clot Removal Catheter by Invamed is a hand-operated mechanical aspiration system designed to immediately remove thrombi or emboli during acute vascular occlusions. Featuring braided balloon-shaped structures, the catheter actively captures clots and pulls them into the lumen, enabling safe, streamlined thrombectomy without complex capital equipment or continuous vacuum lines. Ideal for distal or proximal arterial/venous clots, AngioHAND simplifies acute stroke, limb ischemia, or DVT management.
Braided Balloon-Shaped Capture
- Expandable mesh or braided balloon segments at the distal tip engage and enclose clot mass, guiding it into the catheter lumen.
- Ensures robust clot entrapment without excessive fragmentation or distal embolization.
Manual Vacuum Mechanism
- Operated by a hand-held syringe-like device or integrated handle, creating a controlled negative pressure to aspirate clot into the catheter shaft.
- Minimizes procedural complexity—no large vacuum pumps—offering immediate aspiration capacity at the bedside or in urgent OR settings.
Rapid & Intuitive Thrombectomy
- Inserted percutaneously via a small arterial or venous access; navigated under fluoroscopic guidance to the occlusion site.
- One-hand manipulation of the aspiration handle triggers vacuum and clot removal in real-time, optimizing speed and efficiency.
Enhanced Safety & Vessel Protection
- Balloon-shaped braids gently expand against the vessel walls, preventing the catheter tip from causing undue trauma.
- Reduces the risk of iatrogenic injuries and maintains patency around the extraction zone for improved patient outcomes.
Multiple Clinical Indications
- Acute ischemic stroke retrieval in cerebral arteries (depending on vessel diameter and regulatory approvals).
- Peripheral arterial occlusions (e.g., acute limb ischemia, popliteal thrombosis) or venous thrombi (DVT).
- Use in emergent or elective procedures where fast mechanical clot extraction is paramount.
Specifiche del prodotto
Specifiche | Dettaglio / Valore |
Nome del prodotto | AngioHAND Clot Removal Catheter |
Uso previsto | Manual vacuum-based aspiration of thrombus, emboli, or clot debris in peripheral or coronary vessels |
Design del catetere | Hand-operated syringe or vacuum-based system, flexible polymer shaft with a soft distal tip |
Gamma del diametro esterno | ~5F–7F (depending on model) |
Lumen Inner Diameter | Large bore optimized for clot aspiration |
Lunghezza di lavoro | ~80–120 cm (varies by product code) |
Configurazione dei suggerimenti | Tapered or funnel-shaped tip to facilitate clot ingress |
Radiopaque Marker | Distal marker band for fluoroscopic location |
Vacuum Mechanism | Manual hand-syringe or integrated vacuum lock (no external pump required) |
Sterilità | Sterile, monouso |
Durata di conservazione | ~2–3 years at 15–25 °C |
Indicazioni cliniche | Acute clot removal in peripheral arteries/veins, smaller coronary vessels, or bypass grafts |
Controindicazioni | Severe vessel tortuosity, extremely large clot burden exceeding device capacity, known device material allergy |
Matrice di ordinazione e dimensioni
Diametro esterno (F) | Lunghezza di lavoro (cm) | Tip Style | Codice prodotto | Note |
5F | 80 | Tapered Soft Tip | ANG-HND-5F-80-TS | Smaller diameter for coronary or distal peripheral |
5F | 100 | Funnel Tip | ANG-HND-5F-100-FN | Moderate length, manual vacuum approach |
6F | 80 | Tapered Soft Tip | ANG-HND-6F-80-TS | Common size for peripheral thrombus aspiration |
6F | 120 | Funnel Tip | ANG-HND-6F-120-FN | Extended length for deeper occlusion sites |
7F | 100 | Tapered Soft Tip | ANG-HND-7F-100-TS | Larger lumen for heavier clot burden |
7F | 120 | Funnel Tip | ANG-HND-7F-120-FN | Maximum length plus funnel design for wide clot removal |
Prodotti correlati
-
Mantis CURVE Over-the-Wire (OTW) Rotational Pharmacomechanical Thrombectomy System
Leggi tuttoUn over-the-wire (OTW) device merging rotazionale disruption with pharmacologic lysis, effectively clearing large thrombi while protecting healthy vessel walls.
-
Mantis PRO Rotational Thrombectomy & Ultra Aspiration
Leggi tuttoA rotazionale system featuring for meccanico clot fragmentation plus strong aspiration capabilities in deep venous or arterial occlusions.
-
MultiBEAM Inferior Vena Cava (IVC) Filter
Leggi tuttoA convertible or retrievable IVC filter preventing pulmonary emboli by intercepting clots traveling through the inferior vena cava, ensuring safety in high-risk patients.
-
Inca Trellis Thrombolysis System
Leggi tuttoA catetere delivering thrombolytic agents while filter protection prevents distal embolization, ensuring safer pharmacologic dissolution of clots.