Spider™ Peripheral Detachable Coil System (Detachable Pushable)
A detachable coil kit for embolisasi of peripheral aneurysms, AV fistulas, or abnormal vessels, providing stable coil packing with dikendalikan mechanical detachment.
The Spider™ Peripheral Detachable Coil System in its detachable pushable configuration is engineered by Invamed—a global medical device manufacturer—to address peripheral aneurysm occlusion, vascular malformations, or fistulae requiring controlled coil placement. By offering a pushable yet detachable delivery mechanism, Spider™ affords the precision of in-place detachment without the complexity of electrolytic release, optimizing procedural control and reducing risk of coil migration.
Detachable Pushable Delivery
Combines the ease of a pushable coil insertion with the detachment control typically associated with mechanical or electrolytic systems, enabling safe retrieval or repositioning before final deployment.
Platinum Coil
High radiopacity ensures real-time fluoroscopic monitoring, helping interventionalists confirm accurate coil positioning and packing density.
Soft & Conformable
The flexible coil design adapts to complex vessel anatomies or aneurysmal sacs, minimizing stress on fragile vessel walls.
Versatile Embolization
Ideal for small-to-moderate peripheral aneurysms, arteriovenous malformations (AVMs), or abnormal vascular communications, delivering precise occlusion.
Indikasi
Aneurysm repair (e.g., peripheral, visceral), AVM or fistula occlusion in peripheral territories, or general endovascular procedures requiring dense coil packing.
Kontraindikasi
Vessels too small or tortuous to pass the delivery catheter, active infection at the access site, or scenarios where coil retrieval is not feasible.
Spesifikasi Produk
Spesifikasi | Detail / Nilai |
Nama Produk | Spider Peripheral Detachable Coil System |
Tujuan Penggunaan | Endovascular embolization of peripheral aneurysms, AV fistulas, or abnormal vessels |
Coil Material | Platinum or platinum-tungsten alloy with detachable mechanism |
Detachment Method | Mechanical or electrolytic (verify final model) |
Coil Diameter Range | ~1.5–20 mm (varies by catalog code) |
Coil Length Range | ~1–40 cm (depending on coil diameter and framing vs. filling type) |
Delivery Microcatheter | Typically 2.3–2.7F inner diameter, 0.016–0.021” ID |
Radiopacity | Platinum coil for fluoroscopic visualization |
Kemandulan | Steril, Sekali Pakai |
Umur simpan | ~3–5 years at 15–25 °C |
Indikasi Klinis | Peripheral aneurysm occlusion, AVF closure, selective vessel sacrifice |
Kontraindikasi | Vessels too small or tortuous to accommodate microcatheter, known device material allergies |
Matriks Pemesanan & Ukuran
Coil Diameter (mm) | Coil Length (cm) | Detachment Type | Kode Produk | Catatan |
1.5 | 2 | Mechanical | SPD-P-1.5x2-M | Very small coil for micro-aneurysms |
1.5 | 4 | Electrolytic | SPD-P-1.5x4-E | Extended length, small diameter |
3.0 | 10 | Mechanical | SPD-P-3.0x10-M | Mid-range coil diameter, framing type |
3.0 | 15 | Electrolytic | SPD-P-3.0x15-E | Longer filling coil for larger sac |
5.0 | 15 | Mechanical | SPD-P-5.0x15-M | Medium coil for moderate aneurysms |
5.0 | 20 | Electrolytic | SPD-P-5.0x20-E | Extended coil length, filling type |
10.0 | 20 | Mechanical | SPD-P-10.0x20-M | Larger diameter coil for bigger aneurysms |
10.0 | 40 | Electrolytic | SPD-P-10.0x40-E | Maximum length coil for large-volume occlusion |
Produk Terkait
-
Agen Perawatan Varises VeinOFF
Baca selengkapnyaKhusus sklerosant atau perekat formula yang ditujukan untuk non-termal eliminasi varises, membutuhkan anestesi minimal dan waktu prosedur yang singkat.
-
Sistem Penghapusan Timbal Mekanis Hero
Baca selengkapnyaA mekanis alternatif untuk ekstraksi timbalmenggunakan stylet atau selubung pengunci khusus untuk mencabutnya. lampiran fibrotik, memastikan mantap traksi untuk pemindahan yang aman.
-
Rotablator TemREN
Baca selengkapnyaA rotasi sistem trombektomi atau aterektomi yang menampilkan kecepatan tinggi gerinda ke menggiling atau menghilangkan plak yang mengapur, memastikan perluasan lumen yang lebih baik untuk penempatan stent.
-
Kateter Embolisasi MicroDELIVERY
Baca selengkapnyaMikrokateter yang dioptimalkan untuk tepat pengiriman agen emboli ke wilayah pembuluh darah kecil atau distal, memastikan distribusi yang seragam dan refluks yang minimal.