Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
A rotasi system featuring a leaf tip design for mekanis fragmentasi gumpalan plus kuat kemampuan aspirasi pada oklusi vena atau arteri dalam.
The Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.
Leaf Tip Design
- The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
- Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
Nitinol Shaft with PA/PEBAX
- High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
- Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
Radiopaque Shaft Markings
- Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
- Facilitates accurate positioning and ensures confident navigation through complex vascular pathways.
Flexible Catheter Profiles
- Available in 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
- Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.
Multiple Catheter Lengths
90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.
Spesifikasi Produk
Spesifikasi | Detail / Nilai |
Nama Produk | Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration |
Tujuan Penggunaan | Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems |
Desain Kateter | Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal |
Bahan | Stainless steel or nitinol drive shaft, flexible polymer outer sheath |
Rotational Speed Range | ~40k–80k rpm (check final specs) |
Aspiration Mechanism | Over-the-wire suction or integrated vacuum line |
Catheter Outer Diameter | ~5–7F, depending on model and tip size |
Panjang Kerja | ~80–120 cm (varies by product code) |
Radiopacity | Distal marker near leaf tip for precise positioning under fluoroscopy |
Kemandulan | Steril, Sekali Pakai |
Umur simpan | ~2–3 years at 15–25 °C |
Indikasi Klinis | Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT) |
Kontraindikasi | Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials |
Matriks Pemesanan & Ukuran
Diameter Luar (F) | Panjang Kerja (cm) | Leaf Tip Diameter (mm) | Kode Produk | Catatan |
5F | 80 | 5 | MNT-LF-5F-80-5 | Smaller tip for distal or smaller vessels |
5F | 100 | 5 | MNT-LF-5F-100-5 | Longer shaft, same leaf diameter |
6F | 80 | 6 | MNT-LF-6F-80-6 | Common size for peripheral artery usage |
6F | 120 | 6 | MNT-LF-6F-120-6 | Extended length for deeper or proximal segments |
7F | 100 | 7 | MNT-LF-7F-100-7 | Larger leaf tip for heavier thrombus loads |
7F | 120 | 7 | MNT-LF-7F-120-7 | Max length and larger tip for extensive clot burden |
Produk Terkait
-
Mantis CURVE Over-the-Wire (OTW) Rotational Pharmacomechanical Thrombectomy System
Baca selengkapnyaSebuah over-the-wire (OTW) device merging rotasi disruption with pharmacologic lysis, effectively clearing large thrombi while protecting healthy vessel walls.
-
Sistem Ablasi Frekuensi Radio Vena Varises ThermoBLOCK
Baca selengkapnyaA radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.
-
Agen Perawatan Varises VeinOFF
Baca selengkapnyaKhusus sklerosant atau perekat formula yang ditujukan untuk non-termal eliminasi varises, membutuhkan anestesi minimal dan waktu prosedur yang singkat.
-
Sistem Pelindung Emboli Inca®
Baca selengkapnyaA kateter memberikan trombolitik agen sementara filter mencegah embolisasi distal, memastikan pembubaran gumpalan secara farmakologis yang lebih aman.