Stent Vena Atlas
Sistem implan khusus yang terbuat dari paduan logam yang biokompatibel, yang dirancang untuk mengatasi penyumbatan vena dengan mempertahankan patensi pembuluh darah, meningkatkan aliran darah, dan mengurangi gejala insufisiensi vena kronis.
The Atlas™ Venous Stent, introduced by Invamed.—a global medical device manufacturer—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a berkembang sendiri nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting tahan lama patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Kontraindikasi
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
| Spesifikasi | Detail / Nilai |
| Nama Produk | Atlas™ Venous Stent |
| Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
| Mekanisme Penyebaran | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
| Kekuatan Radial | Moderate to high, designed to resist extrinsic compression |
| Kisaran Diameter Stent | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
| Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
| Penanda Radiopak | Proximal and distal markers for fluoroscopic visualization |
| Kemandulan | Sterile, single use |
| Umur simpan | ~3–5 years if stored at 15–25 °C |
| Indikasi Klinis | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
| Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | Kode Produk | Catatan |
| 10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
| 10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
| 14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
| 14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
| 16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
| 16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
| 20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
Produk Terkait
-

Kateter Pemandu AngioCATH
Baca selengkapnyaKateter pemandu berkinerja tinggi dengan torsi optimal tanggapan dan tip yang tepat bentuk untuk koroner atau periferal intervensi, memastikan pengiriman perangkat yang stabil dan kejernihan pencitraan.
-

Sistem Ablasi Frekuensi Radio Vena Varises ThermoBLOCK
Baca selengkapnyaA radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.
-

Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
Baca selengkapnyaA rotasi system featuring a leaf tip design for mekanis fragmentasi gumpalan plus kuat kemampuan aspirasi pada oklusi vena atau arteri dalam.
-

MultiBEAM Inferior Vena Cava (IVC) Filter
Baca selengkapnyaA convertible or retrievable IVC filter preventing pulmonary emboli by intercepting clots traveling through the inferior vena cava, ensuring safety in high-risk patients.