TemREN Rotablator

A rotációs thrombectomy or atherectomy system featuring high-speed burrs to grind or remove calcified plaque, ensuring better lumen expansion for stent placement.

TemRENRT Rotablator: Management of Calcified Lesions

  • Maximize Stent Success with Advanced Pre-Treatment. Embarking on the treatment of calcified lesions with the TemREN Rotabilator sets the foundation for optimal stent deployment.
  • By employing the power of rotational atherectomy, this leading-edge system ensures the site is ideally prepared for stenting procedures.

Presicion & Reliability of TemRENRT Rotablator

  • Enhance the therapeutic arsenal with the precision and reliability of the TemREN Rotabilator, and set a new standard in patient care.
  • The Temren Rotabilator is not just a tool but a comprehensive system, meticulously designed to conquer the most challenging calcified lesions with finesse and flexibility.

The Pinnacle of Atherectomy Efficiency

  • System Advancer: Offers the flexibility of using multiple-sized catheter burrs independently, ensuring readiness for a diverse range of procedural demands.
  • System Burrs: A versatile selection of burr sizes, from 1.25 mm to 2.50 mm,empowers clinicians to tailor their approach to the unique needs of each lesion.

Empower Your Practice with TemREN: Atherectomy at its Smartest

  • Ellenőrzés: Bluetooth connectivity for remote control via Android and iOS devices.
  • Artificial Intelligence: Embedded AI system for smart, data-driven operation. TemREN delivers smart, data-driven operation, further enhancing its precision and reliability.

THE ROTABLATOR SYSTEM PROVIDES

AN EXCELLENT

OPTION

OR TREATING CALCIFIED LESIONS

Általános termékleírások

Specifikáció Részlet / érték
Termék neve TemREN RT Rotablator
Rendeltetésszerű használat Rotational atherectomy for calcified or fibrotic plaque removal in coronary or peripheral arteries
Burr Material Diamond-coated or Tungsten-Carbide burr (depending on model)
Shaft Material Stainless steel or nickel-titanium alloy with torque-transmitting core
Rotational Speed Range ~60,000 to 200,000 rpm (verify exact device specs)
Burr Diameter Range 1.25–3.00 mm (common range for coronary use; might differ for peripheral)
Length of Working Shaft 135–150 cm (typical)
Vezetődrót kompatibilitás 0.009” or 0.014” (depending on burr size & design)
Control Console TemREN Rotablator Drive Unit (or universal system, if compatible)
Flushing Saline infusion or heparinized solution recommended to cool and lubricate
Sterilitás Steril (etilén-oxid)
Egyszeri használat Igen
Szavatossági idő 2–3 years (if packaging remains sealed and intact)
Üzemi hőmérséklet 15-25 °C ajánlott tárolás
Klinikai javallatok Severely calcified lesions, fibrotic plaque requiring mechanical debulking prior to stent/balloon
Ellenjavallatok Extremely tortuous or dissected vessels, unprotected left main disease, or severe vessel spasm

Coronary Burr Range (1.25–2.00 mm)

Burr Dia (mm) Munkahossz (cm) Recommended Speed (rpm) Guidewire Termék kód Megjegyzések
1.25 135 140k–180k 0.009” TMR-125-135-140180 Ultra-small burr, used for extremely tight lesions
1.50 135 140k–180k 0.009” TMR-150-135-140180 Standard small burr for moderate calcification
1.50 150 60k–160k 0.014” TMR-150-150-60160 Alternate wire compatibility, longer shaft
1.75 135 140k–180k 0.014” TMR-175-135-140180 Common mid-range burr for heavier plaque
1.75 150 80k–160k 0.014” TMR-175-150-80160 Extended working length, slightly slower top rpm
2.00 135 140k–180k 0.014” TMR-200-135-140180 Largest typical coronary burr size
2.00 150 80k–160k 0.014” TMR-200-150-80160 Extended length variant, used in elongated vessels

Peripheral Burr Range (2.00–3.00 mm)

Burr Dia (mm) Munkahossz (cm) Recommended Speed (rpm) Guidewire Termék kód Megjegyzések
2.00 150 60k–140k 0.014” TMR-200-P-150-60140 Peripheral version, large artery usage
2.25 150 60k–140k 0.014” TMR-225-P-150-60140 Slightly bigger burr for moderate-larger peripheral vessels
2.50 150 50k–120k 0.014” TMR-250-P-150-50120 Slower recommended top rpm, robust torque for calcification
2.75 150 50k–120k 0.014” TMR-275-P-150-50120 Heavier plaque removal in iliac or superficial femoral arteries
3.00 150 50k–100k 0.014” TMR-300-P-150-50100 Max burr diameter, typically for large, heavily calcified vessels
2.00 150 60k–140k 0.014” TMR-200-P-150-60140 Peripheral version, large artery usage