ThermoBLOCK वैरिकोज वेन रेडियोफ्रीक्वेंसी एब्लेशन सिस्टम

आकाशवाणी आवृति पृथक मंच के लिए अक्षम सतही नसें, पेशकश थर्मल राहत के लिए सैफेनस या छिद्रित नसों को बंद करना वैरिकाज़ लक्षण।

The Thermal Coagulation RF Ablation Generator एक विकसित, feedback-driven system designed to deliver high-frequency radiofrequency (RF) energy को ThermoBLOCK™ catheters और ThermoBLOCK™ stylets—enabling लक्षित thermal ablation for chronic venous insufficiency (CVI). Equipped with a रियल टाइम monitoring mechanism, the generator precisely regulates intravascular heat parameters, ensuring सुरक्षित और consistent power application while protecting surrounding tissues.

Real-Time Feedback Control
  • Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
  • Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
  • Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing और sealing of incompetent veins.
  • न्यूनतम संपार्श्विक क्षति: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
  • Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
  • Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
  • ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
  • Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
  • Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
  • Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
  • Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing और sealing of incompetent veins.
  • न्यूनतम संपार्श्विक क्षति: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
  • Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
  • Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
  • ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
  • Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.

उत्पाद विनिर्देश

विनिर्देश विस्तार / मूल्य
प्रोडक्ट का नाम ThermoBLOCK Varicose Vein RF Ablation System
उपयोग का उद्देश्य Endovenous radiofrequency ablation (RFA) of incompetent saphenous or perforator veins
RF Catheter Design 6–7F catheter with electrode segment near distal tip, temperature-controlled
Nominal Power ~10–30 W (depends on vein diameter and system setting)
कैथेटर की लंबाई ~60–120 cm (varies by code)
Generator Compatibility ThermoBLOCK RF Generator or universal 460 kHz system
Temperature Monitoring Integrated thermocouple in ablation segment
Treatment Cycle Typically ~20–40 seconds per segment, auto-regulated by temperature feedback
बाँझपन बाँझ, एकल उपयोग
शेल्फ जीवन ~2–3 years at 15–25 °C
नैदानिक संकेत Great saphenous vein (GSV) reflux, small saphenous vein, perforator incompetence
मतभेद Unclear vein anatomy, severe peripheral arterial disease, known intolerance to device materials

ऑर्डरिंग और आकार मैट्रिक्स

कैथेटर आकार (एफ) कैथेटर की लंबाई (सेमी) Ablation Segment (cm) उत्पाद कोड नोट्स
6एफ 60 7 TBLK-6F-60-7 Short catheter for small segments
6एफ 100 7 TBLK-6F-100-7 Standard ablation length, extended shaft
7एफ 100 10 TBLK-7F-100-10 Longer ablation segment for large GSV trunk
7एफ 120 10 TBLK-7F-120-10 For taller patients or more extensive reflux
7एफ 120 15 TBLK-7F-120-15 Extra ablation segment for major trunk veins