Viper ULTRA Thrombolysis Catheter

אן ultra infusion catheter specialized for direct thrombolytic delivery, featuring multi-hole design to uniformly distribute drugs across large clot segments.

ה Viper® Ultrasonic Pharmacomechanical Thrombolysis System הוא זעיר פולשני device designed to dissolve thrombi by combining targeted ultrasonic waves with controlled tPA infusion. By thinning fibrin ו increasing clot porosity, the system enables deeper drug penetration into the thrombus, thereby enhancing the efficacy of pharmacological therapy. This approach helps mitigate potential bleeding complications ו preserves vessel integrity, offering a more refined, patient-centric strategy for acute thrombosis management.

Ultrasonic Wave Delivery
  • Controlled Ultrasound: Low-power ultrasonic energy focuses on fibrin disruption, loosening the structural integrity of the clot.
  • Enhanced Porosity: Breaking fibrin strands encourages tPA to penetrate deeper, ensuring thorough thrombus dissolution.
  • tPA Administration: A site-specific delivery of tissue plasminogen activator (tPA) directly into the clot.
  • Synergistic Effect: Ultrasonic micro-cavitation augments the fibrinolytic effect, requiring lower drug doses and potentially reducing hemorrhagic complications.
  • Minimal Vessel Trauma: Ultrasonic waves are calibrated to avoid damaging valves, vessel walls, or critical structures within the venous or pulmonary vasculature.
  • Reduced Bleeding Risk: Lower overall drug usage and localized infusion can curtail systemic side effects.
  • Controlled Ultrasound: Low-power ultrasonic energy focuses on fibrin disruption, loosening the structural integrity of the clot.
  • Enhanced Porosity: Breaking fibrin strands encourages tPA to penetrate deeper, ensuring thorough thrombus dissolution.
  • tPA Administration: A site-specific delivery of tissue plasminogen activator (tPA) directly into the clot.
  • Synergistic Effect: Ultrasonic micro-cavitation augments the fibrinolytic effect, requiring lower drug doses and potentially reducing hemorrhagic complications.
  • Minimal Vessel Trauma: Ultrasonic waves are calibrated to avoid damaging valves, vessel walls, or critical structures within the venous or pulmonary vasculature.
  • Reduced Bleeding Risk: Lower overall drug usage and localized infusion can curtail systemic side effects.

מפרט מוצר

מִפרָט פירוט / ערך
שם המוצר Viper ULTRA Thrombolysis Catheter
שימוש מיועד Catheter-directed infusion of thrombolytics in acute or subacute thrombus (peripheral, venous, or arterial)
עיצוב קטטר Multi-hole distal segment for uniform drug dispersion, possible radiopaque marker at tip
חוֹמֶר Pebax/Polyamide shaft, potentially braided or reinforced
קוטר חיצוני (F) ~4–6F (depending on infusion lumen capacity)
אורך עבודה ~80–150 cm (varies by product code)
Infusion Ports Distributed side ports over a defined segment for consistent thrombolytic delivery
תאימות חוטי הנחיה Typically 0.014” or 0.018”
עֲקָרוּת סטרילי, לשימוש חד פעמי
חיי מדף ~2–3 years if stored at 15–25 °C in sealed packaging
אינדיקציות קליניות Thrombolytic infusion for DVT, peripheral arterial occlusions, possibly for intra-graft thrombosis
התוויות נגד Highly calcified lesions, severe vessel tortuosity preventing safe passage, known device material allergies

מטריצת הזמנות וגודל

קוטר חיצוני (F) אורך עבודה (ס"מ) Infusion Segment (cm) קוד מוצר הערות
4F 80 10 VPR-4F-80-10 Smaller OD for distal or small vessel usage
4F 120 15 VPR-4F-120-15 Longer shaft, moderate infusion segment
5F 80 10 VPR-5F-80-10 Slightly larger OD for heavier clot load
5F 120 20 VPR-5F-120-20 Extended length with longer infusion zone
6F 100 15 VPR-6F-100-15 Common size for multi-level peripheral lesions
6F 150 30 VPR-6F-150-30 Max length, extensive infusion segment