Spider™ Peripheral Detachable Coil System (Detachable Pushable)
A detachable coil kit for embolization of peripheral aneurysms, AV fistulas, or abnormal vessels, providing stable coil packing with contrôlé mechanical detachment.
The Spider™ Peripheral Detachable Coil System in its detachable pushable configuration is engineered by Invamed—a global medical device manufacturer—to address peripheral aneurysm occlusion, vascular malformations, or fistulae requiring controlled coil placement. By offering a pushable yet detachable delivery mechanism, Spider™ affords the precision of in-place detachment without the complexity of electrolytic release, optimizing procedural control and reducing risk of coil migration.
Detachable Pushable Delivery
Combines the ease of a pushable coil insertion with the detachment control typically associated with mechanical or electrolytic systems, enabling safe retrieval or repositioning before final deployment.
Platinum Coil
High radiopacity ensures real-time fluoroscopic monitoring, helping interventionalists confirm accurate coil positioning and packing density.
Soft & Conformable
The flexible coil design adapts to complex vessel anatomies or aneurysmal sacs, minimizing stress on fragile vessel walls.
Versatile Embolization
Ideal for small-to-moderate peripheral aneurysms, arteriovenous malformations (AVMs), or abnormal vascular communications, delivering precise occlusion.
Indications
Aneurysm repair (e.g., peripheral, visceral), AVM or fistula occlusion in peripheral territories, or general endovascular procedures requiring dense coil packing.
Contre-indications
Vessels too small or tortuous to pass the delivery catheter, active infection at the access site, or scenarios where coil retrieval is not feasible.
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | Spider Peripheral Detachable Coil System |
Utilisation prévue | Endovascular embolization of peripheral aneurysms, AV fistulas, or abnormal vessels |
Coil Material | Platinum or platinum-tungsten alloy with detachable mechanism |
Detachment Method | Mechanical or electrolytic (verify final model) |
Coil Diameter Range | ~1.5–20 mm (varies by catalog code) |
Coil Length Range | ~1–40 cm (depending on coil diameter and framing vs. filling type) |
Delivery Microcatheter | Typically 2.3–2.7F inner diameter, 0.016–0.021” ID |
Radiopacité | Platinum coil for fluoroscopic visualization |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~3–5 years at 15–25 °C |
Indications cliniques | Peripheral aneurysm occlusion, AVF closure, selective vessel sacrifice |
Contre-indications | Vessels too small or tortuous to accommodate microcatheter, known device material allergies |
Commande et matrice des tailles
Coil Diameter (mm) | Coil Length (cm) | Detachment Type | Code produit | Notes |
1.5 | 2 | Mechanical | SPD-P-1.5x2-M | Very small coil for micro-aneurysms |
1.5 | 4 | Electrolytic | SPD-P-1.5x4-E | Extended length, small diameter |
3.0 | 10 | Mechanical | SPD-P-3.0x10-M | Mid-range coil diameter, framing type |
3.0 | 15 | Electrolytic | SPD-P-3.0x15-E | Longer filling coil for larger sac |
5.0 | 15 | Mechanical | SPD-P-5.0x15-M | Medium coil for moderate aneurysms |
5.0 | 20 | Electrolytic | SPD-P-5.0x20-E | Extended coil length, filling type |
10.0 | 20 | Mechanical | SPD-P-10.0x20-M | Larger diameter coil for bigger aneurysms |
10.0 | 40 | Electrolytic | SPD-P-10.0x40-E | Maximum length coil for large-volume occlusion |
Produits similaires
-
TemREN Rotablator
Continuer la lectureA rotationnel système de thrombectomie ou d'athérectomie comprenant à grande vitesse bavures à broyage ou retirer la plaque calcifiée, assurant ainsi une meilleure expansion de la lumière pour la mise en place du stent.
-
Système de suppression du plomb Hero LASER
Continuer la lectureA à base de laser dispositif d'extraction permettant précis et sûr suppression de sondes cardiaques (stimulateur cardiaque ou DCI) en cas d'infection, de dysfonctionnement de la sonde ou de mise à niveau.
-
Système de dénervation rénale Delta
Continuer la lectureA radiofréquence-Système de cathéter basé sur la technologie de l'ADN, spécialisé dans la fabrication de cathéters. sympathique rénal dénervation en hypertension résistanteL'insuline, qui réduit l'activité nerveuse, permet de contrôler la tension artérielle.
-
Atlas Coronary Stent System Acier inoxydable
Continuer la lectureA acier inoxydable offre d'endoprothèses coronaires robuste l'intégrité structurelle et facile pour les interventions coronariennes percutanées (ICP) de routine, en conciliant rentabilité et fiabilité des performances.