MultiBEAM Filtre de la veine cave inférieure (IVC)
Un véhicule convertible ou récupérable Prévention de l'utilisation du filtre IVC embolies pulmonaires en interceptant les caillots qui se déplacent dans la veine cave inférieure, ce qui garantit la sécurité des patients à haut risque.
The MultiBEAM Inferior Vena Cava (IVC) Filter, offered by Invamed—a global medical device manufacturer—is designed to capture and retain thromboembolic fragments traveling within the venous system, thereby reducing the risk of pulmonary embolism (PE). Featuring a self-expanding metallic framework, MultiBEAM provides robust fixation in the IVC while facilitating high patency and stable clot containment.
Self-Expanding Nitinol Struts
Engineered from a biocompatible alloy for secure anchoring, even under shifting venous pressures.
Multi-Spoke or “Beam” Design
Creates multiple capture zones that efficiently trap emboli without significantly restricting blood flow, sustaining venous return.
Retrievable/Optional Permanent
Certain models allow retrieval within a designated window, while others function as permanent PE prophylaxis solutions—offering clinicians flexibility in management.
Reduced Migration & Tilt
Precisely balanced struts help prevent filter migration or tilting, enhancing performance consistency over time.
Wide Application Scope
Indicated for patients at elevated PE risk due to venous thromboembolism (VTE), inadequate response to anticoagulants, or temporary contraindications to anticoagulation therapy.
Contre-indications
Excessively narrow or tortuous IVC diameter preventing secure seating, active infection at insertion site, or patient-specific anatomical constraints.
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | MultiBEAM Filtre de la veine cave inférieure (IVC) |
Utilisation prévue | Prevention of pulmonary embolism by capturing clots traveling from lower extremity or pelvic veins |
Filter Design | Self-expanding metal struts (Nitinol or stainless steel) arranged in a multi-beam pattern |
Mécanisme de déploiement | Over-the-wire or sheath-based insertion, typically via femoral or jugular access |
Retrieval Option | Some models are optionally retrievable within a specific timeframe (check product line) |
Filter Diameter Range | Suited for IVC diameters ~20–30 mm (varies by product code) |
Marqueurs radio-opaques | Distal apex or anchor tips for fluoroscopic identification |
Compatibilité MR | MR Conditional (verify labeling) |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~3–5 years if stored at 15–25 °C in sealed packaging |
Indications cliniques | Patients at risk of pulmonary embolism (PE), especially with contraindications to anticoagulation |
Contre-indications | Severe IVC anatomical anomalies, high-level occlusion, known allergy to device materials |
Commande et matrice des tailles
IVC Diameter Suitability (mm) | Filter Apex to Anchor (mm) | Retrieval Window (days) | Code produit | Notes |
< 24 | 26 | 30 | MBI-<24-40-30 | Smaller IVC or narrow diameters |
< 24 | 26 | 90 | MBI-<24-50-90 | Extended retrieval time |
20–28 | 33 | 30 | MBI-20-28-50-30 | Common range for standard IVC diameters |
20–28 | 33 | 90 | MBI-20-28-60-90 | Longer apex distance + extended retrieval |
28–30 | 33 | 30 | MBI-28-30-60-30 | For larger IVC diameter, shorter retrieval |
28–30 | 33 | 90 | MBI-28-30-70-90 | Largest apex span + extended retrieval |
Produits similaires
-
Mantis PRO Thrombectomie rotationnelle et ultra-aspiration
Continuer la lectureA rotationnel système caractérisé par mécanique fragmentation du caillot plus fort des capacités d'aspiration dans les occlusions veineuses ou artérielles profondes.
-
NOD Valvulotome
Continuer la lectureA titane ou alliage système de plaque sternale fournissant rigide fixation après sternotomie médiane, améliorant ainsi la qualité de l'air. stabilité sternale et de réduire les risques d'infection ou de déhiscence après une chirurgie cardiaque.
-
Cathéters guides AngioCATH
Continuer la lectureCathéters de guidage haute performance avec couple optimal réponse et pointe précise formes pour coronaire ou périphérique garantissant la stabilité du dispositif et la clarté de l'imagerie.
-
Viper™ Cathéters de perfusion à valve
Continuer la lectureLe Viper™ Cathéter de perfusion à valve est un monolumière, pointe à clapet système de livraison qui offre la flexibilité nécessaire pour infuser agents anti-thrombus, contraste radio-opaque ou autres solutions pharmacologiques spécifiées par le médecin avec ou sans un fil-guide en place.